Sponsored Content
Full Discussion: SAN Storage for ASM
Operating Systems Solaris SAN Storage for ASM Post 302486337 by esmgr on Friday 7th of January 2011 07:59:20 PM
Old 01-07-2011
Quote:
Originally Posted by Mack1982
My DBA asked for RAW Volumes (Raid 5)
You just assign the volume of the required size to the system. Check using format command that the volume is there or in our case use the emcpower utitlity
Partition the raw device. START FROM CYLINDER 1 NOT 0. Leave cylinder 0.
Hi and thanks for your reply.

Can you please give me a little more details of how many RAW volumes you created for ASM? Did you create all of them as RAID 5?

Did the DBA also ask you for RAW devices for OCR and Voting disks? It needs just 256MB each but on separate disks (preferably). How did you create those RAW devices?

Thanks again!
 

8 More Discussions You Might Find Interesting

1. Solaris

Using San storage - advice needed

Thinking of using our San for network backups.. Have a Netra 240 being installed and planning to get some space on our San. Do you know what software is used to access the San from my server or what I would need to do? I know how to connect to local storage, disk arrays etc but not sure what... (1 Reply)
Discussion started by: frustrated1
1 Replies

2. Filesystems, Disks and Memory

Switching SAN storage

Hi, I have an existing SUN server that has a SAN storage installed on it. It also has softwares like Appwrox(scheduler), Taradata (database client), Samba Share and a few more installed on it. Now suppose that I have a new unix server server and i switch the same SAN store from the old unix... (1 Reply)
Discussion started by: myloginid
1 Replies

3. AIX

SAN storage and speed

I have 3 SAN disks of 1 TB each. Is it more efficient to make 1 large Volume group with multiple LV's or 3 Volume Groups with 1 LV each. The SAN disk is where all my backups will be dumped.:confused: (1 Reply)
Discussion started by: daveisme
1 Replies

4. Red Hat

how do we check SAN storage?

Hello, I am using LINUX OS. I want to check what is the SAN storage size. How do i check this in server? Any help is really appreciated.. (3 Replies)
Discussion started by: govindts
3 Replies

5. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

6. UNIX for Dummies Questions & Answers

Storage from SAN

hi guys I installed Centos 5.5 (local disk). I am using 2 HBAs Now I mapped 5 LUNs from a Storage. I will be using LVM just to test I assigned a LUN I've read I have to use multipath to avoid my Centos see the LUN twice I enabled mdmpd and multipathd... something else I should do? ... (8 Replies)
Discussion started by: kopper
8 Replies

7. AIX

New to San Storage

Can anyone recommend a good book on san storage basics and how it communicates with an AIX server? (1 Reply)
Discussion started by: NycUnxer
1 Replies

8. UNIX for Advanced & Expert Users

Script to automate add/resize datafile in Oracle ASM Storage

Hi all, Could anyone please share ideas or logic on how to automate add/resize datafile in Oracle ASM Storage for Oracle RAC/Single Node databases when any tablespace space alert is trigerred by OEM? Thanks for your help and time on it! Thanks&regards, a1_win Please DON'T use CODE tags... (0 Replies)
Discussion started by: a1_win
0 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 04:20 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy