Old 11-12-2010
any idea

any idea guys?

I was thinking maybe using hosts.allow/deny

but I am not sure how to use it

hosts.allow
snmpd: 192.168.1.2 192.168.1.3

basically I want any kind of connection to my server but SNMP only 6 servers

how should I ply with hosts.deny/allow or SNMP to do this?
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

sending packets

How can i send a packet, and what is an empty packet? (8 Replies)
Discussion started by: Avatar0fEvil
8 Replies

2. Programming

Packets Getting Lost

I am working on a project, which has the following type of hardware setup. A special hardware device is receiving data from an external network interface. So we can have multiple such a hardware devices. Now these hardware devices will route the captured incoming data through the external... (4 Replies)
Discussion started by: S.P.Prasad
4 Replies

3. IP Networking

counting the packets

there are a number of clients connected to a server.... how can i count that each clients recieve ...? how do i moniter the activity of the client..? (2 Replies)
Discussion started by: damn_bkb
2 Replies

4. Infrastructure Monitoring

capture snmp packets in AIX

Hi, I want to capture snmp packets in AIX. When i give print from AIX6.1, Printer will give its response thru' snmp. I used iptrace command like below, but it is not capturing snmp packets other packets are captured like udp, tcp.. 1. iptrace command: /usr/sbin/iptrace -a -i en0... (1 Reply)
Discussion started by: meeraramanathan
1 Replies

5. HP-UX

packets statistics

Hi there, are there any functions that can get the packets statistics on UNIX ? thanks. (2 Replies)
Discussion started by: Frank2004
2 Replies

6. IP Networking

Sending data from DELL OMSA SNMP and Custom SNMP MIB to same UDP port 161

Hi , Currently DELL OMSA SNMP sends data through default udp port 161.I want my custom SNMP MIB also to send data in the same udp port 161.Whether its possible.If yes where to configure .I tried starting my custom MIB in udp port 161,but it throws port already in use.Kindly guide. (0 Replies)
Discussion started by: prabakar4all
0 Replies

7. Red Hat

Sending data from DELL OMSA SNMP and Custom SNMP MIB to same UDP port 161

Hi , Currently DELL OMSA SNMP sends data through default udp port 161.I want my custom SNMP MIB also to send data in the same udp port 161.Whether its possible.If yes where to configure .I tried starting my custom MIB in udp port 161,but it throws port already in use.Kindly guide. (1 Reply)
Discussion started by: prabakar4all
1 Replies

8. IP Networking

SNMP Problem - SNMP not getting to the agent.

I am having a problem with an SNMP event, and I am not sure where I should be looking to solve this problem. Description: There is an SNMP event in our system that for one reason or another is not getting sent out as an email because it is never getting to our SNMP agent. I see where the... (0 Replies)
Discussion started by: broberts
0 Replies

9. Infrastructure Monitoring

SNMP traps to SNMP server

Dear Champs, I am new to unix, and need to configure linux server to send below traps to a SNMP server. Monitoring TRAP Disk Space Low Monitoring TRAP Memory Low Monitoring TRAP CPU high Monitoring TRAP Admin login/Logoff Please help me how to send this information to my SNMP server... (2 Replies)
Discussion started by: stavar
2 Replies

10. UNIX for Dummies Questions & Answers

Need to transfer all kernel logs (var/log/messages) to the snmp listener as snmp trap

i am working with embedded system -Dell DCS management sub system. my question is as below: currently we are using linux kernel 2.6.30 build and we have a kernel logs stored to the /var/log/messages path. now we have to transfer all this logs to the specified SNMP target as a part of SNMP... (4 Replies)
Discussion started by: vipul_prajapati
4 Replies
CARP(4) 						   BSD Kernel Interfaces Manual 						   CARP(4)

NAME
carp -- Common Address Redundancy Protocol SYNOPSIS
pseudo-device carp [count] DESCRIPTION
The carp interface is a pseudo-device which implements and controls the CARP protocol. carp allows multiple hosts on the same local network to share a set of IP addresses. Its primary purpose is to ensure that these addresses are always available, but in some configurations carp can also provide load balancing functionality. A carp interface can be created at runtime using the ifconfig carpN create command. To use carp, the administrator needs to configure at minimum a common virtual host ID and virtual host IP address on each machine which is to take part in the virtual group. Additional parameters can also be set on a per-interface basis: advbase and advskew, which are used to con- trol how frequently the host sends advertisements when it is the master for a virtual host, and pass which is used to authenticate carp advertisements. Finally carpdev is used to specify which interface the carp device attaches to. If unspecified, the kernel attempts to set carpdev by looking for another interface with the same subnet. These configurations can be done using ifconfig(8), or through the SIOCSVH ioctl. Additionally, there are a number of global parameters which can be set using sysctl(8): net.inet.carp.allow Accept incoming carp packets. Enabled by default. net.inet.carp.preempt Allow virtual hosts to preempt each other. It is also used to failover carp interfaces as a group. When the option is enabled and one of the carp enabled physical interfaces goes down, advskew is changed to 240 on all carp interfaces. See also the first example. Disabled by default. net.inet.carp.log Log bad carp packets. Disabled by default. net.inet.carp.arpbalance Balance local traffic using ARP. Disabled by default. EXAMPLES
For firewalls and routers with multiple interfaces, it is desirable to failover all of the carp interfaces together, when one of the physical interfaces goes down. This is achieved by the preempt option. Enable it on both host A and B: # sysctl -w net.inet.carp.preempt=1 Assume that host A is the preferred master and 192.168.1.x/24 is configured on one physical interface and 192.168.2.y/24 on another. This is the setup for host A: # ifconfig carp0 create # ifconfig carp0 vhid 1 pass mekmitasdigoat 192.168.1.1 netmask 255.255.255.0 # ifconfig carp1 create # ifconfig carp1 vhid 2 pass mekmitasdigoat 192.168.2.1/24 netmask 255.255.255.0 The setup for host B is identical, but it has a higher advskew: # ifconfig carp0 create # ifconfig carp0 vhid 1 advskew 100 pass mekmitasdigoat 192.168.1.1 netmask 255.255.255.0 # ifconfig carp1 create # ifconfig carp1 vhid 2 advskew 100 pass mekmitasdigoat 192.168.2.1 netmask 255.255.255.0 Because of the preempt option, when one of the physical interfaces of host A fails, advskew is adjusted to 240 on all its carp interfaces. This will cause host B to preempt on both interfaces instead of just the failed one. In order to set up an ARP balanced virtual host, it is necessary to configure one virtual host for each physical host which would respond to ARP requests and thus handle the traffic. In the following example, two virtual hosts are configured on two hosts to provide balancing and failover for the IP address 192.168.1.10. First the carp interfaces on Host A are configured. The advskew of 100 on the second virtual host means that its advertisements will be sent out slightly less frequently. # ifconfig carp0 create # ifconfig carp0 vhid 1 pass mekmitasdigoat 192.168.1.10 netmask 255.255.255.0 # ifconfig carp1 create # ifconfig carp1 vhid 2 advskew 100 pass mekmitasdigoat 192.168.1.10 netmask 255.255.255.0 The configuration for host B is identical, except the skew is on virtual host 1 rather than virtual host 2. # ifconfig carp0 create # ifconfig carp0 vhid 1 advskew 100 pass mekmitasdigoat 192.168.1.10 netmask 255.255.255.0 # ifconfig carp1 create # ifconfig carp1 vhid 2 pass mekmitasdigoat 192.168.1.10 netmask 255.255.255.0 Finally, the ARP balancing feature must be enabled on both hosts: # sysctl -w net.inet.carp.arpbalance=1 When the hosts receive an ARP request for 192.168.1.10, the source IP address of the request is used to compute which virtual host should answer the request. The host which is master of the selected virtual host will reply to the request, the other(s) will ignore it. This way, locally connected systems will receive different ARP replies and subsequent IP traffic will be balanced among the hosts. If one of the hosts fails, the other will take over the virtual MAC address, and begin answering ARP requests on its behalf. Note: ARP balancing only works on the local network segment. It cannot balance traffic that crosses a router, because the router itself will always be balanced to the same virtual host. SEE ALSO
netstat(1), sysctl(3), arp(4), arp(8), ifconfig(8), sysctl(8) HISTORY
The carp device first appeared in OpenBSD 3.5. BSD
October 16, 2003 BSD
All times are GMT -4. The time now is 11:27 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy