Sponsored Content
Full Discussion: hpux 11.31 vgimport fail
Operating Systems HP-UX hpux 11.31 vgimport fail Post 302445055 by lamoul on Friday 13th of August 2010 01:46:14 PM
Old 08-13-2010
hpux 11.31 vgimport fail

i'm trying to vgimport the map file from vgexport -p -v -s -m to fail over node (adoptive node in service guard).

root@noe04:/etc/cmcluster/icasprd$ vgimport -s -m gicasprd.110810.map /dev/vgicasprd
vgimport: Volume group "/dev/vgicasprd" already exists in the "/etc/lvmtab" file.

the /etc/lvmtab file has already vgicasprd volume group and all disks associated with. How can i proceed. Is it possible to remove the vgicasprd in /etc/lvmtab file and all disks associated before then try to redo vgimport?

Thanks!
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Mail fail

I am using the shell script file to send mail by "mailx". I do this by cron job, there is no error found. But it is fail, any suggest to me? How can I resend it automatically? Is there any resend logic by using the mailx? (3 Replies)
Discussion started by: adela
3 Replies

2. Shell Programming and Scripting

Need Script to Use CPUs on a HPUX server to simulate Workload Manager on HPUX.

I am running HPUX and using WLM (workload manager). I want to write a script to fork CPUs to basically take CPUs from other servers to show that the communication is working and CPU licensing is working. Basically, I want to build a script that will use up CPU on a server. Any ideas? (2 Replies)
Discussion started by: cpolikowsky
2 Replies

3. Shell Programming and Scripting

Rename fail

I've a lot of file with an hyphen on filename, so I use rename for remove him ad substitute with an underscore but it fails $ rename 's/\-/\_/' * Unknown option: _ Unknown option: i Unknown option: r Unknown option: e Unknown option: e Unknown option: _ Unknown option: g Unknown... (12 Replies)
Discussion started by: cv313x
12 Replies

4. Shell Programming and Scripting

fail on comparison

Hi Am having 2 files. I have one data file. before inserting in to the table am taking cout of the data file and store as data 1. After insert in to the table and am taking the count from the table and store as data2. If i try to compare those values If then echo "data match"... (5 Replies)
Discussion started by: bobprabhu
5 Replies

5. HP-UX

HPUX 11.31 vgextend fail

Hi, when i try to add new disk, it's an XP disk from SAN (lun) to the volume group, it fails because "TOO MANY LINKS" :/etc/cmcluster/icastst$ vgextend /dev/vgicastst /dev/disk/disk684 Current path "/dev/dsk/c51t8d3" is an alternate link, skip. Current path "/dev/dsk/c51t8d4" is an... (2 Replies)
Discussion started by: lamoul
2 Replies

6. HP-UX

pwage-hpux-T for Trusted HPUX servers

I'm sharing this in case anybody needs it. Modified from the original solaris pwage script. This modified hpux script will check /etc/password file on hpux trusted systems search /tcb and grep the required u_succhg field. Calculate days to expiry and notify users via email. original solaris... (2 Replies)
Discussion started by: sparcguy
2 Replies

7. Emergency UNIX and Linux Support

unrecognized vxfs version after vgimport

Hi! We have two HP-UX 11.23. I created VG on host A, exported and imported it on host B, but when I try to mount any LV I get "unrecognized vxfs version" version error. Could anyone please suggest something I can do in this situation? I tried to import VG back to host A and I successfully mounted... (3 Replies)
Discussion started by: Sapfeer
3 Replies

8. HP-UX

fail to boot HPUX

HPUX running in D-Class (L1000), pretty old HPUX version - hpux 11.00 Attempt 1 -- To boot from normal (primary) Unable to boot - system complains failure SYSTEM ALERT System Name : uninitialized DATE : 10/22/2011 Time : 03/41:12 Alert Level 15 = Fatal hardware or configuration... (12 Replies)
Discussion started by: ckwan
12 Replies

9. Linux

Telnet fail

Hi, I try to telnet to server: # telnet xx.xxx.1.72 1521 Trying xx.xxx.1.72... telnet: connect to address xx.xxx.1.72: Connection refused telnet: Unable to connect to remote host: Connection refused iptables is off: # service iptables status Firewall is stopped. # And I have edit... (4 Replies)
Discussion started by: mehrdad68
4 Replies

10. Shell Programming and Scripting

Untar fail

Hi Team, I have a file named as follows: aaa.tar.gz Now I need to verify if the untar fails, then the script has to send a mail. In order to check this condition, I need a tar.gz file which is unable to untar it. Can anyone help me to create a file which I will be able to unzip successfully... (2 Replies)
Discussion started by: kmanivan82
2 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 09:51 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy