Does anyone know if when the Swap Device / Page file in unix is carrying out Page / Swap In's and Page / Swap outs, does it go through the Unix Disk Cache ( I am presuming raw partitions are not being used ) ?
Therefore if there is paging activity on a system ( measured by sar -p, sar -g and... (0 Replies)
Hi guys,
Currently i have a IBM x366 running on Red Hat 4 attached to a DS4800. I've configured 10 LUNs to the server. Somehow, there is a lot buffer io error on device whenever it boot and when i issue the command dmesg.
My kernel is 2.6.9-22.ELsmp. I've updated the hba qla2300 firmware to... (2 Replies)
Hi everyone,
I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN?
At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Dera all
I have error repeating for two day, when I checked the error log by errpt command:
------------------------------------------------------------------------
LABEL: SC_DISK_ERR2
IDENTIFIER: 79B0DF89
Date/Time: Wed Oct 31 02:41:36 SAUS
Sequence Number: 9000... (1 Reply)
I received 4 pre-loaded ready-to-go intel servers running RedHat Enterprise Linux 3 kernel version 2.6.9-22.18 build date june 29, 2006. They are equiped with QLOGIC 2400 dual-port HBA cards. I need to know what utilities or command-sets are available to check these cards out? How do I get their... (4 Replies)
All,
when I do a df -h on a solaris 10 servers I see these san storage filesystems.
cx-fibpool/pyp_u2 588G 151M 345G 1% /pyp/u2
cx-fibpool/pyp_u3 588G 151M 345G 1% /pyp/u3
cx-fibpool/pyp_u4 588G 166G 345G 33% /pyp/u4
cx-fibpool/pyp_u5 ... (7 Replies)
Hi,
I am trying to backup a system ("client") through a slow network using "nim mksysb" on a nim server ("master")
The backup starts, but doesn't success.
Thanks if you can help me to resolve this problem :
Creating information file (/image.data) for rootvg...
Creating list of files to... (2 Replies)
Hi there
Now, Ive always support servers that used multi path software with dual cards, e.g. powerpath (emc ) / MPXIO. I got asked a question today, that if a solaris 8/9/10 host had 2 HBA cards, but no multipathing software, what would happen ?? Does the HBA card with the highest id on the... (2 Replies)
Dear Guru,
IHAC who is using Redhat Linux 5 on DELL M910.
When system bootup, it show "Buffer I/O error on device sdd" error message. Below is the "dmesg" output.
The scenario is:
If more external FC SAN disk LUN add, the device would change other name. So it will impact the raw device... (7 Replies)
Hi, I have a question regarding HBA configuration. Here are the commands' output:
# cfgadm -al | grep fc
c1 fc-fabric connected unconfigured unknown
c2 fc connected unconfigured unknown
c5 ... (11 Replies)
Discussion started by: aixlover
11 Replies
LEARN ABOUT DEBIAN
muroar_stream
muroar_stream(3) muRoar Programmer's Manual muroar_stream(3)NAME
muroar_stream - Create a stream connected to a RoarAudio sound server
SYNOPSIS
#include <muroar.h>
muroar_t muroar_stream (muroar_t fh, int dir, int * stream, int codec, int rate, int channels, int bits);
DESCRIPTION
This function connects a stream to a sound server supporting the RoarAudio protocol. It takes a connected control connection created with
roar_connect(3) and converts it into a connected stream. The socket can no longer be used as control connection.
PARAMETERS
fh The connected control connection.
dir The stream direction for the new stream. For playback of a waveform stream (PCM data) this is MUROAR_PLAY_WAVE. For all possible
values see the offical muRoar manual.
stream This is a pointer to an integer muRoar stores the stream ID in. If your application does not need to know the stream ID of the new
stream this can be set to NULL.
codec This is the codec to be used for the new stream. For signed PCM in host byte order use MUROAR_CODEC_PCM or MUROAR_CODEC_PCM_S. For
unsigned PCM use MUROAR_CODEC_PCM_U. There are a lot other codecs defined. However using a codec not supported by the server will
result an failure of this call. For all possible values see the offical muRoar manual.
rate This is the sample/frame rate the new stream will use. For streams this setting does not make any sense set this to zero.
channels
This is the number of channels for the new stream. For streams this setting does not make any sense set this to zero.
bits This is the number of bits per sample to be used by the data. For streams this setting does not make any sense set this to zero.
RETURN VALUE
On success this call return the new stream IO handle. This may be the same as the control connection or a new one and the control connec-
tion is closed. On error, MUROAR_HANDLE_INVALID is returned.
BUGS
In failure where is no way to tell was was going wrong.
HISTORY
This function first appeared in muRoar version 0.1beta0.
SEE ALSO muroar_connect(3), muroar_close(3), RoarAudio(7).
muRoar April 2012 muroar_stream(3)