Sponsored Content
Operating Systems Solaris Solaris BigAdmin RSS Solaris 10 hba firmware upgrades need help please Post 302433760 by rhfrommn on Wednesday 30th of June 2010 11:52:26 AM
Old 06-30-2010
You can certainly do just the HBA upgrade. All the jumbo patch bundle is is a collection of individual patches applied in a particular order. You just need to determine which patch(es) are the HBA firmware you need then download those specific patches and install them.
 

10 More Discussions You Might Find Interesting

1. Solaris

How to get HBA details in Solaris 9 ?

Hi , How can I collect information about any Hardware , specially HBA (Host Bus Adapter) .... I tried prtdiag but it is not shoing the HBA details. Regards (4 Replies)
Discussion started by: adel8483
4 Replies

2. UNIX for Advanced & Expert Users

How do I know which HBA cards' hardware I have (on Solaris 10) ?

Hi, I'm trying to determine which HBA cards are installed on my Solaris 10 (Sun-Fire-V240) machine. The relevant data I have is below, but from it I cannot ascertain for sure if I have Emulex 10000 or 11000 HBA cards. Can anyone suggest how to determine my HBA hardware ? Thanks, Ron. ... (3 Replies)
Discussion started by: ronbarak
3 Replies

3. Solaris

How do I know which HBA cards' hardware I have (on Solaris 10) ?

Hi, I'm trying to determine which HBA cards are installed on my Solaris 10 (Sun-Fire-V240) machine. The relevant data I have is below, but from it I cannot ascertain for sure if I have Emulex 10000 or 11000 HBA cards. Can anyone suggest how to determine my HBA hardware ? Thanks, Ron. ... (4 Replies)
Discussion started by: ronbarak
4 Replies

4. News, Links, Events and Announcements

Solaris 10 and live upgrades

two articles related to live upgrades that i found useful and noteworthy. Solaris 10 5/08 Live Upgrade Gotcha :: Col’s Tech Stuff Solaris Live Upgrade and Patches :: Col’s Tech Stuff (0 Replies)
Discussion started by: pupp
0 Replies

5. AIX

Update firmware HBA

Hello I have a question I have several partitions P550 Aix 5.3 and I need to update the HBA firmware, in some partitions I have two HBA and in others I have one HBA only. My question is if I have to reboot my partitions after update the firmware level. and If I can do it online or I have... (2 Replies)
Discussion started by: lo-lp-kl
2 Replies

6. AIX

How can I manage redundant HMC upgrades with firmware upgrades?

Lets says I have 2 HMC's A and B, connected to a p570 managed system. Right now the firmware level of the p570 is EM320_076 and that needs to be upgraded to EM340_095. Now the HMC's are at V7R3.3 and as per the code matrix the HMC's needs to be upgraded to V7R3.4 Servicepack 2. Now my... (5 Replies)
Discussion started by: balaji_prk
5 Replies

7. Solaris

hba speed Solaris 9

Hello, In Solaris 10 I can use fcinfo to find what speed the hba ports are running at, am I able to find this out using Solaris 9? I have tried a few variations on luxadm but cant find anything relevant. Thanks. (1 Reply)
Discussion started by: Actuator
1 Replies

8. AIX

I need command for HBA model & firmware please

Hi All, I have a task to complete on several server, I need advice from u guys,i need to know that , how can i check the following thing in AIX server. 1)HBA vendor, HBA model, HBA driver version & HBA firmware. 2) Multipath software & multipath version. 3) Cluster software & cluster... (2 Replies)
Discussion started by: gulamibrahim
2 Replies

9. AIX

How to obtain old version of HBA firmware ?

Hi all: I have a need to down-rev my AIX HBA firmware due to storage instability after upgrading, but IBM support only makes the latest version of firmware available for download. Can anyone provide pointer/tips for obtaining old HBA firmware ? Specifics: 280B HBA df1000fa driver... (1 Reply)
Discussion started by: kwachtler
1 Replies

10. Solaris

Tracing node to a particular HBA in Solaris 9

I have one disk that is reporting I/O errors but the same LUN mounted on a different node is able to access it without issue, is there a way to identify which HBA is being used for the LUN without swapping each out at a time? (4 Replies)
Discussion started by: thmnetwork
4 Replies
pprosvc(1M)						  System Administration Commands					       pprosvc(1M)

NAME
pprosvc - automation service program for Patch Manager SYNOPSIS
/usr/sbin/pprosvc [-c config-name] [-d [-p patch-id [,patch-id...]]] [-h] [-i [-n] [-p patch-id [,patch-id...]]] [-l] DESCRIPTION
Note - This command is deprecated. Use the smpatch analyze, smpatch download, and smpatch update commands instead. See the smpatch(1M) man page. Use the pprosvc command to analyze a system to determine the list of appropriate patches, download the patches, and apply them. This com- mand invokes patch operations in response to a user request or at a scheduled time. You must run this command as superuser. The pprosvc command enables you to do the following: o Analyze the host system for appropriate patches based on an established configuration o Generate the list of appropriate patches o Download the patches to your host system from the Sun patch server o Apply the patches based on a patch policy Use the pprosvc -i command to analyze a system, download the appropriate patches, and apply them. If analysis determines that patches are needed, the pprosvc command downloads them and applies them. Specify other options to automate a subset of the patch management tasks. If you specify the -d option, your system is analyzed and the appropriate patches are downloaded to your system. If you specify the -l option, your system is analyzed and the appropriate patches are listed. The list of patches that is generated by the analysis is based on all of the available patches from the Sun patch server. No explicit information about your host system or its network configuration is transmitted to Sun. Only a request for the Sun patch set is transmitted. The patch set is scanned for patches that are appropriate for this host system, the results are displayed, and those patches are optionally downloaded. The -d, -i, and -l options are mutually exclusive. Use the -p option to specify the patches on which to operate. You can use the -p option with the -d and -i options. OPTIONS
The following options are supported: -c config-name Uses an alternate configuration for the current patch operation. Use the pprosetup command to create new configura- tions. A configuration named recommended is included. For more information, see ``Specifying Alternate Configurations'' in the pprosetup(1M) man page. Note - This feature is not supported by the smpatch command. -d Downloads the patches that are appropriate for this host system. The patches are downloaded to the designated down- load directory. This option generates a list of appropriate patches, as does the -l option. However, instead of just displaying the list of patches, the -d option displays and downloads the patches from the Sun patch server. The patches are down- loaded using a secure connection, and all patches are authenticated using digital signature technology. Only patches that are signed with a Sun digital signature are stored in your download directory. Note - Specifying this option is equivalent to running the smpatch download command. -h Displays information about the command-line options. -i Applies the patches based on the patch policy. This option analyzes your system to generate a list of appropriate patches. If analysis determines that patches are needed, the patches are downloaded and applied. If no patches are permitted to be applied in automatic mode (by running pprosetup -p none), this option is identical to specifying the -d option. If only standard patches are permitted to be applied in automatic mode (by running pprosetup -p standard), all standard patches are applied. Note - Specifying this option is equivalent to running the smpatch update command. -l Generates a list of the patches that are appropriate for this host system. Note - Specifying this option is equivalent to running the smpatch analyze command. -n Runs pprosvc in automatic mode. The command that the cron job specifies is pprosvc -i -n. To schedule patch opera- tions to run in automatic mode, see the pprosetup(1M) man page. In automatic mode, the patch administrator (specified by the -a option) receives email notifications that describe the patches you downloaded and applied, and any error events that occurred. Do not use this option on the command line. Standard patches do not require any special actions on the part of the user. Such patches can be applied by using the patchadd command (see the patchadd(1M) man page) and do not need the host system to reboot for the patch to take effect. All nonstandard patches are moved to the sequester directory if you use the -n option to run in automatic mode. If you run in manual mode, however, nonstandard patches that have properties that match the policy specified by ppros- etup -i are applied. The rest of the nonstandard patches are moved to the sequester directory. You can apply patches from this directory at a later time. Patches, whether standard or nonstandard, that depend on sequestered patches are not applied under any circumstances. Such patches are placed in the sequester directory. For any patch that is placed in the sequester directory, refer to the patch's README file to determine how to apply it to your system. Note - This feature is not supported by the smpatch command. -p [patch-id[,patch-id,.Designates the specific patches on which to operate. Use this option with the -d option or the -i option. The list of patch IDs must be separated by commas. The specified patches are adjusted to use the current versions based on the patch baseline. Patches that are required by the specified patches are added to the complete list of patches to be applied. Note - Specifying this option is equivalent to specifying the -i option to the smpatch analyze, smpatch download, and smpatch update commands. EXAMPLES
Example 1: Applying Specific Patches in Manual Mode # pprosvc -i -p 102893-01,106895-09,106527-05 Applies patches 102893-01, 106895-09, and 106527-05 to the local system in manual mode. Example 2: Analyzing a System and Downloading Appropriate Patches # pprosvc -i Performs an analysis of the current system and downloads the appropriate patches based on all the patches from the Sun patch server. The resulting list of patches can be very long. Example 3: Applying Patches From the Recommended Configuration # pprosvc -c recommended -i Uses the recommended configuration to perform an analysis of the current system and downloads the appropriate patches. Standard patches and those needed from the recommended configuration are applied to the system based on the established patch policy. For information about set- ting the patch policy for manual mode, see the description of the -i option on the pprosetup(1M) man page. ATTRIBUTES
See the attributes(5) man page for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpprou | +-----------------------------+-----------------------------+ |Interface Stability |Obsolete | +-----------------------------+-----------------------------+ SEE ALSO
patchadd(1M), patchrm(1M), pprosetup(1M), smc(1M), smpatch(1M), attributes(5) SunOS 5.10 7 May 2004 pprosvc(1M)
All times are GMT -4. The time now is 03:01 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy