04-20-2010
why not compare and edit the /kernel/drv/fp.conf to enable multipathing globally?
10 More Discussions You Might Find Interesting
1. Solaris
We have loads of Sparc solaris 8 boxes. Each one has 2 physical interfaces and 2 virtuals set up for multipathing (See ifconfig below). Problem is that I cannot ping the qfe0 interface IP from the local machine. I can ping all other local interfaces, but not 10.161.19.5. I can ping it from... (3 Replies)
Discussion started by: tjlst15
3 Replies
2. Solaris
I have solaris 10 sparc. I installed a Qlogic hba card.
This card is connected on a brocade switch and the brocade is connected on 2 different controllers on a Hitachi disk bay.
I formated 2 luns. On my solaris system, i have 4 disk.
How to configure solaris 10 to fix the dual disk view.
... (4 Replies)
Discussion started by: simquest
4 Replies
3. Solaris
Hi,
I saw your post on the forums about how to setup IP multipathing. I wanted your help on the below situation .
I have 2 servers A and B . Now they should be connected to 2 network switches . S1 and S2.
Now is it possible to have IP Multipathing on each of the servers as follows ?
... (0 Replies)
Discussion started by: maadhuu
0 Replies
4. Solaris
Hi,
Basically the original configuration on my Solaris 9 server was two LUNs configured as Veritas file systems that were connected to a NetApp filer (filer1). These two LUNs are still configured on the server - but are not being used. They are there as a backup just in case the new... (0 Replies)
Discussion started by: sparcman
0 Replies
5. Solaris
I 've a doubt about the no. of paths to a disk in my Solaris10 box.
If i run prtdiag i see 12 instances of emulex. Is it 6 dual port HBAs or some other no. how can i check that.
prtdiag | grep LPe11002-S
00 SUNW,emlxs LPe11002-S
00 SUNW,emlxs LPe11002-S
00 ... (3 Replies)
Discussion started by: fugitive
3 Replies
6. Solaris
Hai
we using emc storage which is conneted to M5000 through san switch.
we asign 13 luns but in server it is showing 22 luns.
i enable the solaris multipathing (MPxIO)
#more /kernel/drv/fp.conf in that file
MPxio-disable=no
#mpathadm list lu
it shows ... (2 Replies)
Discussion started by: joshmani
2 Replies
7. Red Hat
I have a server running redhat 5.5 and it has one SAN device presented to it as LUN9. How can I clean up the remaining entries. I cannot afford to interupt the service. Please assist.
# multipath -l
mpath0 (36000097000019260298953666633436) dm-11 EMC,SYMMETRIX
\_ round-robin 0
\_ 2:0:0:9 ... (2 Replies)
Discussion started by: Tirmazi
2 Replies
8. AIX
Hi,
I know the concept of multipathing, but would like to know how to configure multipathing in AIX.
or software/driver is by default present in AIX??????
How to find out wheather multipathing is configured in AIX?????
Regards,
Manu (4 Replies)
Discussion started by: manoj.solaris
4 Replies
9. Solaris
Hi,
I believe this is an OS multipathing issue - Solaris 10
We have x2 Dual port 8GB Qlogic HBA's installed in our SOlaris 10 host.
HBA0 (IOU0) Port WWN's - 09f4 (pci@3,700000/SUNW,qlc@0)
09f5 (pci@3,700000/SUNW,qlc@0,1)
HBA1 (IOU1) Port WWN's... (2 Replies)
Discussion started by: jamba1
2 Replies
10. Red Hat
I have a couple of questions regarding multipath.
If I do vgdisplay vg01, I see it is using 1 PV: /dev/dm-13
If I type multipath -ll I see dm-9, dm-10, dm-11, dm-12, but do not see dm-13. Is my vg01 multipathed? How can I actually know for sure?
Secondly, let's say this time vg01 says... (1 Reply)
Discussion started by: keelba
1 Replies
fp(7d) Devices fp(7d)
NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)