Sponsored Content
Operating Systems Linux Raid0 recovery from external HD Post 302390012 by dangral on Tuesday 26th of January 2010 04:12:57 PM
Old 01-26-2010
I'm not too familar with Linux RAID. With what options would I run the mdadm?
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Password recovery

We recently terminated a developer at my place of employment who created scripts on a windows server (that i do not have access to) that invoke FTP sessions on my UnixWare 7.1.1 servers. I need to know the password that is being used. Does anyone know of a good password crack? (8 Replies)
Discussion started by: rm -r *
8 Replies

2. Solaris

Solaris RAID0 doubt...

friends, Suppose I am typing metastat command and it is showing: d100: Concat/Stripe Size: 369495 blocks (180 MB) Stripe 0: (interlace: 32 blocks) Device Start Block Dbase Reloc c1d0s0 16065 Yes Yes c1d0s1 0 No Yes... (4 Replies)
Discussion started by: saagar
4 Replies

3. Solaris

Solaris recovery

Some thing happened to our solaris 10 ( sparc ) box and it is not coming up now. These are some of the console messages : I assume it is not able to find very basic system libraries so i need to tell it some how to find it under /lib:/usr/lib. I booted it from the CD but now i... (4 Replies)
Discussion started by: rajwinder
4 Replies

4. UNIX for Dummies Questions & Answers

Why is RAID0 faster?

I have read anecdotes about people installing RAID0 (RAID - Wikipedia, the free encyclopedia) on some of their machines because it gives a performance boost. Because bandwidth on the motherboard is limited, can someone explain exactly why it should be faster? (7 Replies)
Discussion started by: figaro
7 Replies

5. UNIX for Advanced & Expert Users

live upgrade with raid0 soft partitions

Hi, I have this mirrored system with soft-partitions. I have a difficulty determining the lucreate cmd in this env. #metastat -p d0 -m d10 d20 1 d10 1 1 c1t2d0s0 d20 1 1 c1t3d0s0 d1 -m d11 d21 1 d11 1 1 c1t2d0s5 d21 1 1 c1t3d0s5 d100 -p d1 -o 58720384 -b 8388608 d200 -p d1 -o... (1 Reply)
Discussion started by: chaandana
1 Replies

6. Hardware

HP9000 Server - Stuck on RAID0

Hey all, I've got an old HP9000 L1000 server with HP-UX installed. The drives that the OS is running on are in RAID0. I am concerned for the reliability of the server. The four hard drives in the front of the server are LVD 18.2 drives. I know with RAID0, if one drive fails, they all fail. ... (2 Replies)
Discussion started by: mroselli
2 Replies

7. Solaris

Cloning RAID0 drives, Solaris 10u11

Hello all, this is my first time posting here. Where I work we have multiple servers (x3-2's) running Solaris 10u11 with 2 drives configured as RAID0, 300GB per. There are 4-6 open slots for drives to clone to. Past attempts to clone/backup these drives has failed. One of the machines is... (1 Reply)
Discussion started by: eprlsguy
1 Replies

8. Gentoo

Data recovery of formatted external HDD

accidentally formatted ext3 external hard disk .. im using EAse us tool in windows system to recover the data ... will this works?? if yes ... the another external hard disk have to be formatted in which file system ? is there any other option ..please help me out (1 Reply)
Discussion started by: rajeshz
1 Replies

9. Solaris

Solaris 11 recovery

Hi, I need to recover the Solaris 11 OS, and it backup via Netbackup 7.6 file level backup only. Does anyone know what are steps to recover it? Thanks. :confused::confused::confused: (3 Replies)
Discussion started by: freshmeat
3 Replies

10. UNIX for Dummies Questions & Answers

Raid0 array stresses only 1 disk out of 3

Hi there, I've setup a raid0 array of 3 identical disks using : mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity : dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Discussion started by: chebarbudo
8 Replies
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD
March 3, 2008 BSD
All times are GMT -4. The time now is 11:29 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.