Sponsored Content
Operating Systems Linux mdadm - Swapping 500GB disks for 1TB Post 302386054 by mark54g on Monday 11th of January 2010 07:21:13 AM
Old 01-11-2010
An easier way might be this. If you have enough space on the 1TB drive to fit all your data, then add 1 1TB drive after failing out 1 of the RAID 5 drives. Copy your data. Remove the other drives in the RAID 5 and use the remaining drives to create an md RAID 5 with 1 drive missing. You can specify that you are doing so
Copy the data from the single 1TB drive to the array, then add that drive to the array after initializing it.
 

10 More Discussions You Might Find Interesting

1. Solaris

500Gb Maxtor USB disk on Solaris 9

Does anyone succesfully is able to get the drive to work on Solaris 9? The OS recognizes the drive, however 'format -e' says "drive type unknown' I then set CHS manually, but only 120Gb shows. thanks. (2 Replies)
Discussion started by: tuan_quan
2 Replies

2. Solaris

Multiple Backups to USB 1TB Drives using dd

First of all, great web site! I have been using it for a while but just registered today. It's been a great resource for me. Now, on to my issue.;) I'm geographically separated from six (Sun v245s) development servers that I have been asked to backup and restore as development is done and... (11 Replies)
Discussion started by: ShawnD41
11 Replies

3. UNIX for Advanced & Expert Users

mdadm question

Hello, I have 4 drives (500G each) in a raid 10, I got a power failior and this is the result? cat /proc/mdstat Personalities : md126 : inactive sdb sdc sdd sde 1953536528 blocks super external:-md127/0 md127 : inactive sdd(S) sde(S) sdb(S) sdc(S) 9028 blocks super... (3 Replies)
Discussion started by: rmokros
3 Replies

4. UNIX for Advanced & Expert Users

mdadm container! How does it work

Hi everyone, I am not sure if I understand how mdadm --create /dev/md0 --level=container works? A device called /dev/md0 appears in /proc/mdstat but I am not sure how to use that device? I have 2 blank drives with 1 500GB partition on each. I would like to setup mirroring, but not in the... (0 Replies)
Discussion started by: hytron
0 Replies

5. AIX

Can't backup more than ~1TB.

Hello all, I create a backup of a file system with hostA # find . | backup -iqvf /backup/hostA.fsA.backup After a while I get the following error message: backup medium write error: File too large Check backup media and rerun the backup /backup is a NFS mount and is the backup device... (5 Replies)
Discussion started by: petervg
5 Replies

6. Red Hat

mdadm for / and /boot

had this RHEL 5 installation with /dev/sda1 and /dev/sda2 running.. created two more partitions /dev/sdj1 and /dev/sdj2 , the same sized partition as /dev/sda trying to use mdadm to create RAID1 .. I cannot even do it in "rescue" mode, I wonder if it can be done.. it kept... (2 Replies)
Discussion started by: ppchu99
2 Replies

7. UNIX for Advanced & Expert Users

Speed problems with tar'ing a 500Gb directory on an eSATA drive

I'm trying to compress a directory structure on an external hard drive, connected by eSATA cable to my linux (Ubuntu 10.04) desktop. The total volume is 500Gb with half a million files, ranging from Kb to Mb in size. The drive is 2Tb, with 0.8Tb free space before compression. running "tar -pcf... (10 Replies)
Discussion started by: omnisppot
10 Replies

8. Solaris

Hot swapping disks on V240 - blue light not lit after cfgadm -c unconfigure

Hot swapping a drive on V240. So, I do cfgadm -c unconfigure <disk>. Then cfgadm -al reports disk as unconfigured as expected. format then tells me there is no disk. BUT, blue light does not come on. Done the exact same command on my V440 and blue light does come on. V240 Server Admin... (0 Replies)
Discussion started by: psychocandy
0 Replies

9. Shell Programming and Scripting

Splitting a file into chunks of 1TB

Hi I have a file with different filesystems with there sizes. I need to split them in chucks of 1TB. The file looks like vf_MTLHQNASF07_Wkgp2 187428400 10601AW1 vf_MTLHQNASF07_Wkgp2 479504596 10604AW1 vf_MTLHQNASF07_Wkgp2 19940 10605AID vf_MTLHQNASF07_Wkgp2 1242622044... (4 Replies)
Discussion started by: bombcan
4 Replies

10. Filesystems, Disks and Memory

MDADM Failure - where it came from?

Hello, i have a system with 6 sata3 seagate st3000dm01 disks running on stable Debian with software raid mdadm. i have md0 for root and md1 for swap and md2 for the files. i now want to add one more disk = sdh4 for md2 but i got this errors: The new disk is connected to an 4 port sata... (7 Replies)
Discussion started by: Sunghost
7 Replies
saconfig(1M)															      saconfig(1M)

NAME
saconfig - Command Line Configuration Utility for the HP SmartArray RAID Controller Family SYNOPSIS
<device_file> <device_file> -N <device_file> -R <RAID_level> [-S <stripe_size>] -p <physical_drive_id> [-p <physical_drive_id> ...] [-s <physical_drive_id>] [-c <capac- ity>] <device_file> -e <low|medium|high> <device_file> -r <low|medium|high> <device_file> -P <default|shortest|longest> <device_file> -A <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s all <device_file> -D <logical_drive_num> <device_file> -D all <device_file> -C <read_caching_percentage> <device_file> -F on <device_file> -F off <device_file> -I -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -I -l <logical_drive_num> <device_file> -E <logical_drive_num> -c <capacity> <device_file> -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] <device_file> -M <logical_drive_num> -S <stripe_size> DESCRIPTION
The command is a command line configuration tool for the HP SmartArray RAID Controller Family. This command provides the ability to create a logical drive, add a spare drive to existing logical drive, display configuration, delete a logical drive, and clear configuration. This command also enables the cache when it is used to create the first logical drive on the SmartArray RAID Controller. Furthermore it allows the option of changing the percentage of total cache size used for read caching and write caching. The auto-fail missing disks at boot fea- ture can be enabled or disabled using this command. Prerequisites needs to be able to create the /tmp/saconfig.lock file when it starts executing. This prevents multiple users from running This lock file is removed when exits. Security Restrictions requires either the superuser privilege or and privileges. See privileges(5) for more information about privileged access on systems that support fine-grained privileges. Options recognizes the following options and parameters as indicated in the SYNOPSIS section above. <device_file> To specify the device file for the SmartArray RAID Controller. The device file is as displayed by the command for the appropriate SmartArray RAID Controller. With no other options, displays size and status for all physical drives and RAID level, size, and status for all logical drives. With the option saconfig displays size and status for all physical drives and RAID level, size, and status for all logical drives. But the persistent device files (see intro(7)) will be displayed as against legacy device files in the absence of this option. -R <RAID_level> To create a logical drive with the specified RAID level. The supported RAID levels are 0, 1, 1+0, 5, and ADG. The lowest logical drive number not already in use will be given to the newly created logical drive, starting from 0. To determine the hardware path and device file for the logical drive, use the command. The logical drives are dis- played in the same order as in the output. RAID 1+0 logical drive requires even number of physical drives (minimum of 2). To achieve optimal fault tolerance, it is best to specify the same number of physical drives per channel if possible when creating a RAID 1+0 logical drive. This ensures the physical drives in each mirrored pairs would be on different channels. -S <stripe_size> To specify the stripe size for the logical drive to be created. The supported stripe sizes are 8, 16, 32, 64, 128, and 256 (KB). 128 and 256 stripe sizes are not available for RAID 5 or ADG logical drive. If this option is not used to specify the stripe size, default stripe size will be used to create the logical drive. For RAID 0 and 1+0 logical drive, the default size is 128. For RAID 5 and ADG logical drive, the default size is 16. -p <physical_drive_id> To specify the SCSI physical disk. It can be represented as <channel_id>:<target_id> (e.g., 4:12). Valid channel numbers are between 1 and 4. Valid target numbers are between 0 and 15. To specify the SAS/SATA physical disk. It can be represented as either <connector>:<enclosure>:<bay> (e.g., 2I:1:10) or <wwid> (e.g., 0x500000e010f16432). -s <physical_drive_id> To specify a spare drive to be included in the logical drive configuration. Refer <physical_drive_id> to -p option. -c <capacity> To specify the size in GB of a logical drive to be created. -A <logical_drive_num> To specify which logical drive to add spare drive to. -e <low | medium | high> To change the expand priority of controller to one of Low, Medium, High. When there are no logical drives, expand priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subse- quent logical drive creation will change the expand priority value of the controller to medium. -r <low | medium | high> To change the rebuild priority of controller to one of Low, Medium, High. When there are no logical drives, rebuild priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subsequent logical drive creation will change the rebuild priority value of the controller to high. -P <default | shortest | longest> To change the path selection method by the controller firmware. If it is set to default, firmware will select the Active path on its own. If the selection method is set to shortest, firmware will select the shortest path as the Active Path. If the path selection method is longest, firmware will select the longest path as the Active Path. All multi path configurations are Active-Standby configurations. -D <logical_drive_num> -s <physical_drive_id> To delete the spare drive from the specified logical drive. -D <logical_drive_num> -s all To delete all of spare drives from the specified logical drive. -D <logical_drive_num> To delete the specified logical drive. -D all To clear configuration. -C <read_caching_percentage> To specify the percentage of total cache size to be used for read caching. The remaining percentage will be used for write caching. Valid read caching percentage numbers are 0, 25, 50, 75, and 100 (%). -F on To enable auto-fail missing disks at boot feature. -F off To disable auto-fail missing disks at boot feature. -I -p <physical_drive_id> [-p <physical_drive_id> ...] To identify SAS/SATA physical drive(s) by LED. -I -l <logical_drive_num> To identify a SAS/SATA logical drive by LED. -E <logical_drive_num> -c <capacity> To extend the capacity of the specified logical drive up to larger capacity. The capacity is in GB. -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] To expand the specified logical drive and others in an array by physical drive(s). -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] To perform RAID level [with stripe size] migration on the specified logical drive. The stripe size is in KB. -M <logical_drive_num> -S <stripe_size> To perform stripe size migration on the specified logical drive. The stripe size is in KB. Logical Drive State Definitions All physical disks in the logical drive are operational. Some possible causes: Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive have failed. One or more disks in a RAID 0 logical drive have failed. Cache data loss has occurred. Array expansion was aborted. The logical drive is temporarily disabled because another logical drive on the controller had a missing disk at power-up. Also known as "degraded" state. A physical disk in a fault tolerant logical drive has failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID ADG, data loss may result if two additional disks should fail. A replacement disk is present, but rebuild hasn't started yet (another logical drive may be currently rebuilding). The logical drive will also return to this state if the rebuild had been aborted due to unrecoverable read errors from another disk. One or more physical disks in this logical drive are being rebuilt. While the logical drive was in a degraded state, the system was powered off and a disk other than the failed disk was replaced. Shut off the system and replace the correct (failed) disk. While the system was off, one or more disks were removed. Note: the other logical drives are held in a temporary "failed" state when this occurs. The data in the logical drive is being reorganized because: Physical disks have been added to the array (capacity expansion). The stripe size is being changed (stripe-size migration). The RAID level is being changed (RAID-level migration). A capacity expansion operation is in progress (or is queued up) that will make room on the disks for this new logical drive. Until room has been made on the physical disks, this newly configured logical drive cannot be read or written. The logical drive is waiting to undergo data reorganization (see EXPANDING above). Possible causes for the delay are a rebuild or expansion operation may already be in progress. Physical Disk State Definitions The physical disk is configured in one or more logical drives and is operational. The physical disk is configured as a spare disk. The physical disk has not been configured in any logical drives. The configured physical disk has failed. Return Value returns the following values: Successful completion. Command line syntax error. Incompatible CISS driver API. Failure opening a file. Other error. Examples To display configuration on the SmartArray RAID Controller /dev/ciss5 - To create a RAID 1+0 logical drive to include physical drives 4:0 and 4:1 and spare drive 4:2 - -R -p -p -s To create a RAID ADG logical drive with stripe size 64 to include physical drives 1:2, 2:2, 3:2 and 4:2 - -R -S -p -p -p -p To create a RAID 5 logical drive with capacity 45 GB to include SAS physical drives 1I:1:16, 1I:1:15, and 1I:1:14 - -R -c -p -p -p To set the expand priority of logical drives on a controller to medium -e To set the rebuild priority of logical drives on a controller to high -r To add spare drive 1:0 to logical drive 1 - -A -s To delete spare drive 1:0 from logical drive 1 - -D -s To delete all spare drives from logical drive 1 - -D -s To delete logical drive 0 - -D To clear configuration - -D To change read caching percentage to 75% - -C To extend logical drive 2 upto 45 GB in capacity - -E -c To expand logical drive 0 with 2 SAS physical drives - -E -p -p To migrate logical drive 2 with stripe 32 - -M -S To migrate logical drive 2 to RAID level 5 with stripe 64 - -M -R -S AUTHOR
was developed by HP. FILES
Executable file. saconfig lock file. Device files. SEE ALSO
sautil(1M), privileges(5), intro(7). saconfig(1M)
All times are GMT -4. The time now is 09:59 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.