Operating Systems AIX Need EMC Symmetrix driver for AIX 5.3 Post 302377422 by vbe on Friday 4th of December 2009 04:38:06 AM
Old 12-04-2009
Why? its state is available, you need now make it useable as a PV:
Code:
chdev -l hdisk495 -a pv=yes

 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Good sites to learn EMC symmetrix

i need to learn this very quick. i'm not trying delve deep into it. just enough to do basic things. does anyone know of any good sites to visit?? (1 Reply)
Discussion started by: TRUEST
1 Replies

2. HP-UX

is anybody using EMC symmetrix?

Hello, I'm looking for reference sites using HP-UX and EMC symmetrix disk. Then, May I ask you questions? (6 Replies)
Discussion started by: cooldugong
6 Replies

3. UNIX for Advanced & Expert Users

AIX MPIO and EMC

We are looking at running MPIO for it's redundancy and load balancing benefits. Does anyone know what pieces of software or modules are needed on the VIO server to get load balancing to work. Remember we are using EMC's DMX3500 storage system. We no longer want to use Powerpath. :rolleyes: ... (2 Replies)
Discussion started by: vxg0wa3
2 Replies

4. HP-UX

Adding a new set of hardisk in EMC Symmetrix

Hello everyone! Could anybody help me how to configure a set of disk? From our existing EMC storage, we still have spaces for a new set of disk. I know how to replace a deffective disk but never had experience in setting/replacing a new pair of disk (M1 and M2). My objective here is to increase... (1 Reply)
Discussion started by: Tris
1 Replies

5. AIX

Configurin EMC SAN disks on AIX

This may sound like an absolute rookie question, and it is. I have been working on Migrating our HP and Solaris servers to the new EMC SAN and know the routines backwards. Now we've suddenly got a new IBM server and I don't even know how to check if it is connected to the switch. Can someone... (1 Reply)
Discussion started by: ronellevan
1 Replies

6. AIX

AIX STREAMS driver question

Hi all, I have a AIX kernel STREAMS question need your help, I need to implement a firewall on AIX and get packet raw data then decide pass or drop it, I've seen similiar firewall code on HP-UX, on HP-UX, you have to implement a "dlpi STREAMS driver", and specify it as a "dlpi" driver in... (1 Reply)
Discussion started by: rocktilldie
1 Replies

7. AIX

AIX Sanboot from EMC Symmetrix with NPIV

Hi All.. On to a new implementation with AIX 7.1 san boot from EMC disks (Using NPIV). Anyone played with this recently? Wondering if we need PowerPath on the AIX clients or has native MPIO matured to replace it. Thoughts? Thanks Mr B (6 Replies)
Discussion started by: balaji_prk
6 Replies

8. Hardware

Difference between platform driver,codec driver and Machine driver

In general terms what are the differences platform driver,codec driver and Machine driver? (1 Reply)
Discussion started by: rupeshkp728
1 Replies

9. AIX

AIX Migration issue with EMC ODM sets

Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this : lslpp -l | grep EMC ... (7 Replies)
Discussion started by: JME2015
7 Replies

10. AIX

AIX help -reconnect EMC lun

we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)