Sponsored Content
Operating Systems SCO Warning HD: no root disk controller was found Post 302356183 by mselvaprakash on Thursday 24th of September 2009 09:43:46 PM
Old 09-24-2009
there are three disk they are

" Segate cheetah Model no: ST318406LC ultra3 SCSI 10k 18GB "

three disk are same disk
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

warning:hd:no root disk controler was found

hi all i use sco open server reliseas 5 on my system i get an image from system hard disk to another hard disk with acronis software and start system with new(backup)hard disk, but during the boot process some errors generate as follow warning:hd:noroot disk controler was found hd:a boot-time... (2 Replies)
Discussion started by: mehran_malek
2 Replies

3. HP-UX

[Joy Share] - Replace an unknown status controller on HP FC60 disk array

Replace an unknown status controller on HP FC60 disk array Author:JoyOnline JoyChangLu@gmail.com Trouble description: The users detected that the status of controller at A is unknown. Analysis and diagnostic: Physical observed all leds on enclosure of disk array is normal. The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

Lost Root Password on VXVM Encapsulated Root Disk

Hi All Hope it's okay to post on this sub-forum, couldn't find a better place I've got a 480R running solaris 8 with veritas volume manager managing all filesystems, including an encapsulated root disk (I believe the root disk is encapsulated as one of the root mirror disks has an entry under... (1 Reply)
Discussion started by: sunnyd76
1 Replies

9. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

10. Solaris

Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1)

Hi, I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error: WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1): SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
WREN(3) 						     Library Functions Manual							   WREN(3)

NAME
wren, ata - hard disk interface SYNOPSIS
bind #H[drive] /dev bind #w[target[.lun]] /dev /dev/hd0disk /dev/hd0partition /dev/sd0disk /dev/sd0partition ... DESCRIPTION
The hard disk interfaces (wren, #w, is a SCSI disk; ata, #H, is an IDE or ATA disk) serve a one-level directory giving access to the hard disk partitions. The parameter to attach defines the numerical SCSI target and logical unit number or the IDE drive number to access. Both default to zero. Each partition name is prefixed by hd and the numeric drive identifier. The partition always exists and covers the entire disk. The size of each partition as reported by stat(2) is the number of bytes in the partition, so the size of is the size of the entire disk. The partition also always exists; it is the last block on the disk for SCSI, second to last for IDE. If it contains valid partition data, those partitions will be visible as well. Every time the device is bound, the partitions are updated to reflect any changes in the parti- tion file. The format of the partition file is the string plan9 partitions on a line, followed by partition specifications, one per line, consisting of a name and textual strings for the block start and limit for each partition on the disk. The program prep(8) writes the partition table for the disk; its use is preferred to writing it by hand. SEE ALSO
prep(8), scsi(3) SOURCE
/sys/src/9/port/devwren.c /sys/src/9/pc/devata.c WREN(3)
All times are GMT -4. The time now is 08:33 AM.