Sponsored Content
Full Discussion: 3510 Disk Array Problem
Top Forums UNIX for Advanced & Expert Users 3510 Disk Array Problem Post 302345200 by Tirmazi on Tuesday 18th of August 2009 04:37:12 PM
Old 08-18-2009
3510 Disk Array Problem

I have a 3510 disk array attached to a T2000 server.
The dmesg command shows disk error as follows and is generated a couple of times during the day

Aug 18 03:35:51 myserver SUNWscsdMonitor[575]: [ID 373880 daemon.error] [SUNWscsd 0x030B1E00:0x01000216 Informational] <rctrl6042> Standard General Event, CHL:2 ID:22 Drive NOTICE: Drive Recovered Error - 5F8E1F (01/18/07).[info: 4B8-01191B5B3] (Secondary, Mon Aug 17 17:07:36 2009) {Unique ID#: 003fb3}

I have done an iostat such as follows but it is showing the logical drives

Code:
 ---- errors ---
  s/w h/w trn tot
    2   0   0   2 c0t0d0
    5   1   7  13 c1t0d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A809d0
    1   3   2   6 c6t600C0FF000000000003FB36EDC23A808d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A807d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A806d0
    1   3   1   5 c6t600C0FF000000000003FB36EDC23A805d0
    1   3   2   6 c6t600C0FF000000000003FB36EDC23A804d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A803d0
    1   5   4  10 c6t600C0FF000000000003FB36EDC23A802d0
    1   4   2   7 c6t600C0FF000000000003FB36EDC23A801d0
   65   6   2  73 c6t600C0FF000000000003FB36EDC23A800d0

My question is how do I find out what is the underlying physical drive that is giving the problem.

From sccli or by any other command set how do I pin point the WWN or the location of the drive giving the problem.

Kindly assist

Thanks

Last edited by DukeNuke2; 08-18-2009 at 05:43 PM.. Reason: added code tags
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Problemwith 3510 array.

I have 2 3510FC arrays, one a JBOD with (7) 146GB drives, and the other with dual RAID controllers, also (7) 146GB drives. The idea was to get 1TB mirrored. Anyway, after installing the Enterprise Storage Manager on a connected V880, I was able to use the "sccli" command and see/configure all the... (7 Replies)
Discussion started by: ridgeback00
7 Replies

2. Solaris

adding existing disks to a 3510 array

I would like to extend a logical drive on our 3510. I have four unallocated disks which I would like to use for this purpose. The 3510 supports a Sun Cluster but for now all I wish to see is a "new" disk when I run format. I am a little familiar with the telnet/ssh session on the 3510 but am... (2 Replies)
Discussion started by: malcqv
2 Replies

3. Solaris

storEDGE A5000 disk Array

Do you know how do I make my solaris 8 detect the storEDGE A5000?. I have problem making it recognise, without that I cannot install VxVM. Any ideas? (7 Replies)
Discussion started by: calsum
7 Replies

4. Solaris

SE 3510 Battery Issue

Hi everyone, I changed the batteries on 29-Jun-2008 for the storedges. But received error messages from the server today,I used the "-u" option to update the service date information but it syntaticaly fails. Why? Jul 4 12:00:03 auriga SUNWscsdServer: <rctrl8001> The battery on... (3 Replies)
Discussion started by: incredible
3 Replies

5. Solaris

EFI Disk labels on 3510 raid array

Hi Peeps, Can anyone help me an EFI lablel on a 3510 raid array that I cannot get rid of, format -e and label just asks you if you want to label it. Want an SMI label writing to it. Anyone got any ideas on how to remove the EFI label? Thanks in advance Martin (2 Replies)
Discussion started by: callmebob
2 Replies

6. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

7. UNIX for Advanced & Expert Users

Disk Array

HI: I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers) Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information. The way that the servers see the disk array, is like... (1 Reply)
Discussion started by: pmoren
1 Replies

8. UNIX for Dummies Questions & Answers

Raid0 array stresses only 1 disk out of 3

Hi there, I've setup a raid0 array of 3 identical disks using : mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity : dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Discussion started by: chebarbudo
8 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
diskd(1)						      General Commands Manual							  diskd(1)

Name
       diskd - disk daemon; wait for disk to be inserted

Note
       This  manpage has been automatically generated from fdutils's texinfo documentation.  However, this process is only approximative, and some
       items, such as cross-references, footnotes and indices are lost in this translation process.  Indeed, these items have no appropriate  rep-
       resentation  in	the  manpage  format.  Moreover, only the items specific to each command have been translated, and the general information
       about fdutils has been dropped in the manpage version.  Thus I strongly advise you to use the original texinfo doc.

       *      To generate a printable copy from the texinfo doc, run the following commands:

		     ./configure; make dvi; dvips fdutils.dvi

       *      To generate a HTML copy,	run:

		     ./configure; make html

	      A pre-made HTML can be found at: `http://www.tux.org/pub/knaff/fdutils'

       *      To generate an info copy (browsable using emacs' info mode), run:

		     ./configure; make info

       The texinfo doc looks most pretty when printed or as HTML.  Indeed, in the info version certain examples are difficult to read due  to  the
       quoting conventions used in info.

Description
       The diskd command has the following syntax:

	  diskd [-d drive] [-i interval] [-e command]

       Diskd  waits for a disk to be inserted into a given drive, and then either executes the command or exits. This program can be used to auto-
       matically mount a disk as soon as it is inserted.

Warning
       This program works by switching the motor on for a very short interval, and then seeking to track -1. This might  damage  hardware  in  the
       long  run.  Amigas,  which  also  use these techniques, are known for having problems with their disk drives no longer spinning up properly
       after a few month of usage.

Options
       -d drive
	      Selects the drive to observe for disk insertion. By default, drive 0 (/dev/fd0) is observed.

       -i interval
	      Selects the polling interval. The interval is given in tenths of seconds. Default is 10 (one second).

       -e command
	      Gives the command to be executed when a disk is inserted. If no command is given the program simply exits.  Typically,  the  command
	      mounts the disk. It can be a shell scripts which probes for several filesystems and disk geometries until it succeeds.

Bugs
       *      Automatic  unmounting  cannot yet be handled. It is indeed not enough to scan for disk removal, because when the disk is removed, it
	      is already too late: There might be some buffers needing flushing.  However, the fdmountd program  allows  automatic  unmounting	by
	      using the SYNC mount options, which switches off write buffering (see section  fdmount).

       *      The drive motor is running all the time, and on some computers, the drive led flickers at each time the drive is polled.

See Also
       Fdutils' texinfo doc

fdutils-5.5							      03Mar05								  diskd(1)
All times are GMT -4. The time now is 12:48 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy