I have 2 3510FC arrays, one a JBOD with (7) 146GB drives, and the other with dual RAID controllers, also (7) 146GB drives. The idea was to get 1TB mirrored. Anyway, after installing the Enterprise Storage Manager on a connected V880, I was able to use the "sccli" command and see/configure all the... (7 Replies)
I would like to extend a logical drive on our 3510. I have four unallocated disks which I would like to use for this purpose.
The 3510 supports a Sun Cluster but for now all I wish to see is a "new" disk when I run format.
I am a little familiar with the telnet/ssh session on the 3510 but am... (2 Replies)
Do you know how do I make my solaris 8 detect the storEDGE A5000?.
I have problem making it recognise, without that I cannot install VxVM.
Any ideas? (7 Replies)
Hi everyone,
I changed the batteries on 29-Jun-2008 for the storedges.
But received error messages from the server today,I used the "-u" option to update the service date information but it syntaticaly fails. Why?
Jul 4 12:00:03 auriga SUNWscsdServer: <rctrl8001> The battery on... (3 Replies)
Hi Peeps,
Can anyone help me an EFI lablel on a 3510 raid array that I cannot get rid of, format -e and label just asks you if you want to label it. Want an SMI label writing to it.
Anyone got any ideas on how to remove the EFI label?
Thanks in advance
Martin (2 Replies)
So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
HI:
I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers)
Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information.
The way that the servers see the disk array, is like... (1 Reply)
Hi there,
I've setup a raid0 array of 3 identical disks using :
mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity :
dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT DEBIAN
diskd
diskd(1) General Commands Manual diskd(1)Name
diskd - disk daemon; wait for disk to be inserted
Note
This manpage has been automatically generated from fdutils's texinfo documentation. However, this process is only approximative, and some
items, such as cross-references, footnotes and indices are lost in this translation process. Indeed, these items have no appropriate rep-
resentation in the manpage format. Moreover, only the items specific to each command have been translated, and the general information
about fdutils has been dropped in the manpage version. Thus I strongly advise you to use the original texinfo doc.
* To generate a printable copy from the texinfo doc, run the following commands:
./configure; make dvi; dvips fdutils.dvi
* To generate a HTML copy, run:
./configure; make html
A pre-made HTML can be found at: `http://www.tux.org/pub/knaff/fdutils'
* To generate an info copy (browsable using emacs' info mode), run:
./configure; make info
The texinfo doc looks most pretty when printed or as HTML. Indeed, in the info version certain examples are difficult to read due to the
quoting conventions used in info.
Description
The diskd command has the following syntax:
diskd [-d drive] [-i interval] [-e command]
Diskd waits for a disk to be inserted into a given drive, and then either executes the command or exits. This program can be used to auto-
matically mount a disk as soon as it is inserted.
Warning
This program works by switching the motor on for a very short interval, and then seeking to track -1. This might damage hardware in the
long run. Amigas, which also use these techniques, are known for having problems with their disk drives no longer spinning up properly
after a few month of usage.
Options-d drive
Selects the drive to observe for disk insertion. By default, drive 0 (/dev/fd0) is observed.
-i interval
Selects the polling interval. The interval is given in tenths of seconds. Default is 10 (one second).
-e command
Gives the command to be executed when a disk is inserted. If no command is given the program simply exits. Typically, the command
mounts the disk. It can be a shell scripts which probes for several filesystems and disk geometries until it succeeds.
Bugs
* Automatic unmounting cannot yet be handled. It is indeed not enough to scan for disk removal, because when the disk is removed, it
is already too late: There might be some buffers needing flushing. However, the fdmountd program allows automatic unmounting by
using the SYNC mount options, which switches off write buffering (see section fdmount).
* The drive motor is running all the time, and on some computers, the drive led flickers at each time the drive is polled.
See Also
Fdutils' texinfo doc
fdutils-5.5 03Mar05 diskd(1)