Sponsored Content
Full Discussion: 3510 Disk Array Problem
Top Forums UNIX for Advanced & Expert Users 3510 Disk Array Problem Post 302345200 by Tirmazi on Tuesday 18th of August 2009 04:37:12 PM
Old 08-18-2009
3510 Disk Array Problem

I have a 3510 disk array attached to a T2000 server.
The dmesg command shows disk error as follows and is generated a couple of times during the day

Aug 18 03:35:51 myserver SUNWscsdMonitor[575]: [ID 373880 daemon.error] [SUNWscsd 0x030B1E00:0x01000216 Informational] <rctrl6042> Standard General Event, CHL:2 ID:22 Drive NOTICE: Drive Recovered Error - 5F8E1F (01/18/07).[info: 4B8-01191B5B3] (Secondary, Mon Aug 17 17:07:36 2009) {Unique ID#: 003fb3}

I have done an iostat such as follows but it is showing the logical drives

Code:
 ---- errors ---
  s/w h/w trn tot
    2   0   0   2 c0t0d0
    5   1   7  13 c1t0d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A809d0
    1   3   2   6 c6t600C0FF000000000003FB36EDC23A808d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A807d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A806d0
    1   3   1   5 c6t600C0FF000000000003FB36EDC23A805d0
    1   3   2   6 c6t600C0FF000000000003FB36EDC23A804d0
    1   2   0   3 c6t600C0FF000000000003FB36EDC23A803d0
    1   5   4  10 c6t600C0FF000000000003FB36EDC23A802d0
    1   4   2   7 c6t600C0FF000000000003FB36EDC23A801d0
   65   6   2  73 c6t600C0FF000000000003FB36EDC23A800d0

My question is how do I find out what is the underlying physical drive that is giving the problem.

From sccli or by any other command set how do I pin point the WWN or the location of the drive giving the problem.

Kindly assist

Thanks

Last edited by DukeNuke2; 08-18-2009 at 05:43 PM.. Reason: added code tags
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Problemwith 3510 array.

I have 2 3510FC arrays, one a JBOD with (7) 146GB drives, and the other with dual RAID controllers, also (7) 146GB drives. The idea was to get 1TB mirrored. Anyway, after installing the Enterprise Storage Manager on a connected V880, I was able to use the "sccli" command and see/configure all the... (7 Replies)
Discussion started by: ridgeback00
7 Replies

2. Solaris

adding existing disks to a 3510 array

I would like to extend a logical drive on our 3510. I have four unallocated disks which I would like to use for this purpose. The 3510 supports a Sun Cluster but for now all I wish to see is a "new" disk when I run format. I am a little familiar with the telnet/ssh session on the 3510 but am... (2 Replies)
Discussion started by: malcqv
2 Replies

3. Solaris

storEDGE A5000 disk Array

Do you know how do I make my solaris 8 detect the storEDGE A5000?. I have problem making it recognise, without that I cannot install VxVM. Any ideas? (7 Replies)
Discussion started by: calsum
7 Replies

4. Solaris

SE 3510 Battery Issue

Hi everyone, I changed the batteries on 29-Jun-2008 for the storedges. But received error messages from the server today,I used the "-u" option to update the service date information but it syntaticaly fails. Why? Jul 4 12:00:03 auriga SUNWscsdServer: <rctrl8001> The battery on... (3 Replies)
Discussion started by: incredible
3 Replies

5. Solaris

EFI Disk labels on 3510 raid array

Hi Peeps, Can anyone help me an EFI lablel on a 3510 raid array that I cannot get rid of, format -e and label just asks you if you want to label it. Want an SMI label writing to it. Anyone got any ideas on how to remove the EFI label? Thanks in advance Martin (2 Replies)
Discussion started by: callmebob
2 Replies

6. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

7. UNIX for Advanced & Expert Users

Disk Array

HI: I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers) Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information. The way that the servers see the disk array, is like... (1 Reply)
Discussion started by: pmoren
1 Replies

8. UNIX for Dummies Questions & Answers

Raid0 array stresses only 1 disk out of 3

Hi there, I've setup a raid0 array of 3 identical disks using : mdadm --create --verbose /dev/md0 --level=stripe --raid-devices=3 /dev/sdb1 /dev/sdc1 /dev/sdd1I'm using dstat to monitor the disk activity : dstat --epoch -D sdb,sdc,sdd --disk-util 30The results show that the stress is not... (8 Replies)
Discussion started by: chebarbudo
8 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
voldiskadd(8)						      System Manager's Manual						     voldiskadd(8)

NAME
voldiskadd - Adds one or more disks for use with the Logical Storage Manager SYNOPSIS
/usr/sbin/voldiskadd disk-address-list DESCRIPTION
The voldiskadd utility sets up new disks that are added to the system after the initial system installation and configures the disks for use by the Logical Storage Manager. A valid disk label must exist on the disk before using the voldiskadd utility. One or more disks may be specified using a disk-address-list. Disk addresses in the list have the form dskn (for the entire disk) or dsknp (for a specific partition). When specifying multiple disks, use a space between entries. Disk address names relate directly to device names in the /dev/disk directory. For example, here are some valid voldiskadd disk-address-list specifications: # voldiskadd dsk1 # voldiskadd dsk2 dsk3a The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadd. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadd utility prompts the user for a disk group name and disk media name for the disks. If a new disk group name is specified, that disk group is created for the new disks. If no disk group name is specified, the disks are left as unassigned replacement disks for future use. If an existing disk group name is specified, the user is prompted for whether the disks should be designated as spares for the disk group. If a disk is found to already contain non-Logical Storage Manager partitioning, the user is asked whether the disk should be encapsulated. Encapsulation turns each partition of the disk into a volume. A disk should be encapsulated if it contains file systems or data that should not be overwritten. If encapsulation is not desired for a disk, the disk can be initialized as a new disk for use by the Logical Storage Manager. For new disks, all space on the disk becomes free space in the disk's disk group. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. The voldiskadd utility supports the following general classes of actions: Initializing a disk with reserved regions and partitions. Disk initialization is performed by calling voldisksetup command. Adding a disk to an existing disk group. This operation can be performed independently of the initialization of the disk drive to add a disk's storage space to a disk group's free space pool. The volassist command may subsequently allocate from that free space. The disk can also be added as a hot spare device. Creating new disk groups in which to import new disks. If no disk group exists for importing disks, the option of creating the disk group is offered. Encapsulating disks that have exist- ing contents. This is the default action for disks that do not have a valid, existing Logical Storage Manager private region, but that do have a disk label. Encapsulation is performed by calling volencap. Reconnecting a drive that was temporarily inaccessible. This situation is detected automatically, by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the volrecover script. ERRORS
You may receive the following messages when using the voldiskadd command: Initialization of disk device special-device failed. Error: special-device or an overlapping partition is open. This message indicates that the partition you specified or an overlapping partition on the disk is actively in use. The partition could be a mounted UFS or AdvFS filesystem, initialized as an LSM disk or used as a swap device. special-device is marked in use for fstype in the disklabel. If you continue with the operation you can possibly destroy existing data. Would you like to continue?? [y,n,q,?] (default: n) This message indicates that the fstype of a partition or an overlapping partition is set in the disk label. The voldiskadd command prints this message to warn that a disk partition may have valid data which could be destroyed. If you are sure that the disk partition does not have valid data and that the partition can be added to LSM, you can ignore the warning message by entering y at the prompt. The voldiskadd command will proceed to initialize the disk partition and add it to LSM. FILES
A list of disks to exclude from use by voldiskadd. SEE ALSO
disklabel(8), volassist(8), voldisk(8), voldiskadm(8), voldisksetup(8), voldg(8), volintro(8) voldiskadd(8)
All times are GMT -4. The time now is 07:15 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy