you have a few options here depending on your environment.

in the ivm, under view/modify virtual storage, you can create virtual disks to be used for the aix lpars. the downside to this option is that you may get i/o contention from the vios and aix lpar sharing the same disk.

a better option (requiring a san) would be to assign a separate lun for the vios and aix lpar. this allows for easy recovery should you lose the vios and want to migrate the aix lpar to another vios.
 

10 More Discussions You Might Find Interesting

1. AIX

rebooting vio client

Hi, I would like to reboot vio client but I am not able to access vio client(I am not able to get putty) , I am able to get putty of vio server, is there any command by using which from vio server I can reboot vio client? (3 Replies)
Discussion started by: manoj.solaris
3 Replies

2. AIX

Finding cpu information on vio client

Hi, I am having single p series blade with Single Physcial CPU with dual core, on that vio server is installed, I have created vio client allocate 0.9 each cpu , now when I am running prtconf command on vio client it is showing "2" no of processor, My query using which command it will... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

Unable to connect VIO client

Hi I am facing very strange issue on my vio server 5 vio clients are confgured, now I am to connect 3 vio client , i am unable to connect 2 vio client my ip address,subnet mask,gateway is correct. i have rebooted and reconfigured the ip address, but issue is persists. Kindly suggest how to... (0 Replies)
Discussion started by: manoj.solaris
0 Replies

4. AIX

how will i know if a lun has been already mapped to a vio client

Hi im logged in to the vio servers now. when i give # lspv | wc -l i get the count as 6246 how will i know if a lun has been already mapped to a vio client or it is left free without mapping to any of the vio client ? (1 Reply)
Discussion started by: newtoaixos
1 Replies

5. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

6. AIX

Mirroring vio server

Hi, I would like to know installing vio server on local disk and mirroring rootvg, if I am creating AIX VIO CLIENT(lpar), and any of single local hard disk failuare. will it affect lpars? will lpars able to boot. what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies

7. AIX

cdrom confusion on the vio client lpar

Hi In my vio server I have the below output $ lsvopt | grep -i SAPSITGS sapsitgs_cdrom TL12UP.iso 3182 In my vio client lpar I have the below output root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies

8. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

9. AIX

Chef client on VIOs? How do you manage your VIO configs?

I know the VIOs are generally to be treated as an appliance and one should never drop down to oem_setup_env. In reality however, oem is a very useful tool to get the job done. So that leads me into the question of using the Chef client on a VIO. Currently a big push to manage all our *nix... (4 Replies)
Discussion started by: RecoveryOne
4 Replies

10. AIX

Need to replace a broken PV in a VIO VG used for client LPARs (and it won't release the old one)

I have a broken PV in a VIO VG that's used to support client LPARs using LVs. On the client LPAR, I reduced all PVs from the relevant client VG and thus deleted it. I.e. there is no client LPAR using the VIO VG. Yet when I try to reducevg the VIO VG, it complains that the LV hosted on the PV is... (2 Replies)
Discussion started by: maraixadm
2 Replies
vgmove(1M)																vgmove(1M)

NAME
vgmove - move data from an old set of disks in a volume group to a new set of disks SYNOPSIS
autobackup] diskmapfile vg_name autobackup] diskfile diskmapfile vg_name DESCRIPTION
The command migrates data from the existing set of disks in a volume group to a new set of disks. After the command completes successfully, the new set of disks will belong to the same volume group. The command is intended to migrate data on a volume group from old storage to new storage. The diskmapfile specifies the list of source disks to move data from, and the list of destination disks to move data to. The user may choose to list only a subset of the existing physical volumes in the volume group that need to be migrated to a new set of disks. The format of the diskmapfile file is shown below: source_pv_1 destination_pv_1_1 destination_pv_1_2 .... source_pv_2 destination_pv_2_1 destination_pv_2_2 .... .... source_pv_n destination_pv_n_1 destination_pv_n_2 .... If a destination disk is not already part of the volume group, it will be added using see vgextend(1M). Upon successful completion of the source disk will be automatically removed from the volume group using see vgreduce(1M). After successful migration, the destination disks are added to the LVM configuration files; namely, or The source disks along with their alternate links are removed from the LVM configuration files. A sample diskmapfile is shown below: /dev/disk/disk1 /dev/disk/disk51 /dev/disk/disk52 /dev/disk/disk2 /dev/disk/disk51 /dev/disk/disk3 /dev/disk/disk53 The diskmapfile can be manually created, or it can be automatically generated using the diskfile and diskmapfile options. The argument diskfile contains a list of destination disks, one per line such as the sample file below: /dev/disk/disk51 /dev/disk/disk52 /dev/disk/disk53 When the option is given, reads a list of destination disks from diskfile, generates the source to destination mapping, and saves it to diskmapfile. The volume group must be activated before running the command. If the command is interrupted before it completes, the volume group is in the same state it was at the beginning of the command. The migration can be continued by running the command with the same options and disk mapping file. Options and Arguments The command recognizes the following options and arguments: vg_name The path name of the volume group. Set automatic backup for this invocation of autobackup can have one of the following values: Automatically back up configuration changes made to the volume group. This is the default. After this command executes, the command is executed for the volume group; see vgcfgbackup(1M). Do not back up configuration changes this time. Specify the name of the file containing the source to destination disk mapping. If the option is also given, will generate the disk mapping and save it to this filename. (Note that if the diskmapfile already exists, the file will be overwritten). Otherwise, will perform the data migration using this diskmapfile. Specify the name of the file containing the list of destination disks. This option is used with the option to generate the diskmapfile. When the option is used, no volume group data is moved. Preview the actions to be taken but do not move any volume group data. Shared Volume Group Considerations For volume group version 1.0 and 2.0, cannot be used if the volume group is activated in shared mode. For volume groups version 2.1 (or higher), can be performed when activated in either shared, exclusive, or standalone mode. Note that the daemon must be running on all the nodes sharing a volume group activated in shared mode. See lvmpud(1M). When a node wants to share the volume group, the user must first execute a if physical volumes were moved in or out of the volume group at the time the volume group was not activated on that node. LVM shared mode is currently only available in Serviceguard clusters. EXTERNAL INFLUENCES
Environment Variables determines the language in which messages are displayed. If is not specified or is null, it defaults to "C" (see lang(5)). If any internationalization variable contains an invalid setting, all internationalization variables default to "C" (see environ(5)). EXAMPLES
Move data in volume group from to After the migration, remove from the volume group: Generate a source to destination disk map file for where the destination disks are and SEE ALSO
lvmpud(1M), pvmove(1M), vgcfgbackup(1M), vgcfgrestore(1M), vgextend(1M), vgreduce(1M), intro(7), lvm(7). vgmove(1M)
All times are GMT -4. The time now is 10:42 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy