06-29-2009
to assign all lun from SP B to SP A:- use this
trespass_array cxtxdxsx -B
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist?
Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies
2. AIX
Hi Guys,
I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one.
I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors:
... (4 Replies)
Discussion started by: zxmaus
4 Replies
3. Red Hat
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies
4. Solaris
Hello,
I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN.
This is the situation :
Server is a SUN Enterprise M5000
OS = Solaris10 Sparc
Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies
5. Solaris
Here is the issue:
I am building a database server using Solaris 10x86 U8.
The system is jumpstarted with mpxio enabled and booting from the san.
We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies
6. AIX
Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies
7. Linux
Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
echo "1" > /sys/class/fc_host/host<n>/issue_lip
and
echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies
8. Solaris
Hi all
I am running the following hardware:
2 SUN Solaris 10 machines
They are connected to EMC clarion LUNs
We are running a Sun Cluster 3.2 managing both nodes
We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies
9. Solaris
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies
10. Solaris
Hi,
We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs.
The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies
LEARN ABOUT HPUX
io_redirect_dsf
io_redirect_dsf(1M) io_redirect_dsf(1M)
NAME
io_redirect_dsf - redirect the persistent device special file from one device to a different device
SYNOPSIS
old_hw_path new_hw_path
old_dsf new_dsf
DESCRIPTION
The command reassigns a persistent device special file (DSF) to a new device when both devices belong to the same class. If the new device
does not already exist, before reassigning it you must create the DSF by running either or (see insf(1M) and mksf(1M)).
In the first form, the command accepts as input the lun hardware paths of the device to be replaced and the new device. In the second
form, the command accepts as input the persistent DSFs of the device to be replaced and the new device.
Note: The device is inaccessible while the redirection is taking place.
Options
recognizes the following options:
Specify the hardware path of the device that is being replaced.
returns an error if old_hw_path is not a lun hardware path.
Specify the hardware path of the new device.
returns an error if new_hw_path is not a lun hardware path.
Specify the device special file of the device that is being replaced.
returns an error if old_dsf is not a persistent DSF.
Specify the device special file of the new device.
returns an error if new_dsf is not a persistent DSF.
RETURN VALUE
Exit values are:
Successful completion.
An error condition occurred.
EXAMPLES
Redirect the DSF with the hardware path at to point to the hardware path at Both disks belong to the class.
Redirect the DSF to point to the device with DSF Both DSFs represent devices that belong to the class
WARNINGS
You must be superuser to execute the command.
SEE ALSO
insf(1M), mksf(1M), intro(7).
io_redirect_dsf(1M)