In HACMP it is wise to use the same major number for each volume group throughout the cluster - makes identifikation of corresponding disks so much easier.

I hope this helps.

bakunin
 

9 More Discussions You Might Find Interesting

1. Programming

Device Major/Minor numbers

To further my fledgling knowledge of C, I am re-writing some of the Unix command set. My current command is an ls-style command. All works well, except for device files. How do I get the major/minor numbers for the dev files? I see from the stat struct there are st_rdev and st_dev members. Do... (1 Reply)
Discussion started by: zazzybob
1 Replies

2. Solaris

major & minor number

Hi Can anyone tell me what is major number and minor number in the mknod command. Also what these numbers mean. I have gone through the man pages but still I couldn't understand. Regards (3 Replies)
Discussion started by: RajaRC
3 Replies

3. Shell Programming and Scripting

sort major.minor.release_build_x

would like to order this input based on major.minor.release AND build number Label abc_def_0.0.3_build_999 2008/08/01 'Created by me.' Label abc_def_0.0.9_build_1000 2008/08/01 'Created by me.' Label abc_def_9.0.9_build_10001 2008/08/01 'Created by me.' Label abc_def_10.9.100_build_2... (4 Replies)
Discussion started by: gurpal2000
4 Replies

4. Solaris

Help with Major and minor number

Hi Does anyone know what the major and minor numbers are in Solaris? (2 Replies)
Discussion started by: wisdom
2 Replies

5. AIX

how do I change major-minor numbers of disk devices

Good evening ... does anyone of you know how to change major/minor numbers of disk devices ? I had to migrate from raid1 to raid5 and this messed up my ASM cluster - I know which devices should have which IDs to match the content - but I have no idea how to change it. Any help would be... (2 Replies)
Discussion started by: zxmaus
2 Replies

6. Programming

which head file for major and minor function?

#include <sys/types.h> #include <sys/stat.h> #include <sys/termios.h> #include <stdio.h> #include <stdlib.h> #include <stddef.h> #include <string.h> #include <unistd.h> #include <signal.h> #include <sys/mkdev.h> int main(int argc, char *argv) { int i; struct stat buf; ... (4 Replies)
Discussion started by: konvalo
4 Replies

7. Shell Programming and Scripting

How to filter out major and minor?

Hi, I have line like this : proj_name/module/trunk/module_1_0 where the first "1" refers to major version and second "0" refers to minor version. any AWK or command like that so that I can filter out the major and minor ? like major= command | input line minor= command |... (4 Replies)
Discussion started by: bhaskar_m
4 Replies

8. Solaris

Major and Minor number of Virtual File System

Hi friends, Please let me know if there is any way to find out Major and Minor numbers of virtual file system like below: /devices 0K 0K 0K 0% /devices ctfs 0K 0K 0K 0% /system/contract proc 0K 0K ... (8 Replies)
Discussion started by: nitj
8 Replies

9. Shell Programming and Scripting

Filtering my major and minor values

I want to remove all rows with a minor repeating count less than 30% compared to the major repeating count from my table. The values of a col(starting col 2) can assume is A,T,G,C and N. Each row has at least 2 values and at most 4 repeating values(out of ATGC). N is considered a missing value... (12 Replies)
Discussion started by: newbie83
12 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 09:18 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy