You should be able to take the disk with the LVM info on it, do a vgscan on it and import the VG information. You may need to do a vgimport
 

9 More Discussions You Might Find Interesting

1. Linux

Problem for restoring lvm on different disks

Hi all, I have a server running in RH ES4, the SCSI HD are running in RAID 1. I backup the LVM config by using 'vgcfgbackup' and then remove all the HD. I insert another HD (same size & branch but different model) into the machine and run linux rescue to recreate the... (0 Replies)
Discussion started by: donaldfung
0 Replies

2. UNIX for Advanced & Expert Users

LVM - Extending Logical Volume within Volume Group

Hello, I have logical volume group of 50GB, in which I have 2 logical volumes, LogVol01 and LogVol02, both are of 10GB. If I extend LogVol01 further by 10GB, then it keeps the extended copy after logical volume 2. I want to know where it keeps this information Regards Himanshu (3 Replies)
Discussion started by: ghimanshu
3 Replies

3. Solaris

How to resize mirror volume in veritas volume manager 3.5 on Solaris 9 OE

Hi all, I have a problem with vxvm volume which is mirror with two disks. when i am try to increase file system, it is throwing an ERROR: can not allocate 5083938 blocks, ERROR: can not able to run vxassist on this volume. Please find a sutable solutions. Thanks and Regards B. Nageswar... (0 Replies)
Discussion started by: nageswarb
0 Replies

4. SuSE

Remove disks from VGs in LVM

Hi, I have following set up on Open suse 11 vgdisplay pvdisplay lvdisplay I would like to remove these disks /dev/sdb and /dev/sdc from LVM and do not use them for anything.. Can anyone please help me with this ? (1 Reply)
Discussion started by: upengan78
1 Replies

5. Solaris

RAID manager or veritas volume manager

Can somebody kindly help me to determine which one i should choose to better manipulate OS volume. RAID manager or veritas volume manager? Any critical differences between those two? Thanks in advance. (5 Replies)
Discussion started by: beginningDBA
5 Replies

6. UNIX for Dummies Questions & Answers

VERITAS Volume Manager - mirror a disk/volume

I have a machine (5.10 Generic_142900-03 sun4u sparc SUNW,Sun-Fire-V210) that we are upgrading the storage and my task is to mirror what is already on the machine to the new disk. I have the disk, it is labeled and ready but I am not sure of the next steps to mirror the existing diskgroup and... (1 Reply)
Discussion started by: rookieuxixsa
1 Replies

7. Red Hat

Create volume using LVM over 2 physical disks

I wanted to know how we can combine volumes over 2 physical drives. # fdisk -l Disk /dev/sda: 42.9 GB, 42949672960 bytes 255 heads, 63 sectors/track, 5221 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sda1 ... (16 Replies)
Discussion started by: ikn3
16 Replies

8. Red Hat

Configure LVM to gain access to the data on disks

Hello friends, We had to upgrade RHEL 4.x to 5.7 so we took complete backup. Since DIRECT UPGRADE not possible, we rebuilt 5.7 from scratch. We had lvm configuration on DATA disks in previous OS and now we need to configure such that we should be able to have same old LVM configuration (like... (1 Reply)
Discussion started by: prvnrk
1 Replies

9. Solaris

Disks are not visible in Veritas Volume manager

Hi I have created a new setup for VCS for doing some testing on virtual box. After creating 3 Solaris 10 machine (147148-26) with VCS. Here I have used one machine as ISCSI Storage. VCS Version is bash-3.2# /opt/VRTS/bin/haclus -value EngineVersion 6.0.10.0 bash-3.2# bash-3.2# pkginfo... (4 Replies)
Discussion started by: hb00
4 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)