thats interesting...you are right, I have checked the outputs of systems I set up, and looks like after firmware upgrade it gives more comprehensive information.
this is the output of one T5220, and firmware is up to date
Hello all ,
This is the output of my prtdiag command ...The speed of each of the CPUs is listed below (1281 MHz ) ..That's fine ..I'm confused about the (System clock frequency: 183 MHZ ) ..What is the difference between System Clock freq and CPU freq ...THanks..
System Configuration: Sun... (5 Replies)
Hi everyone,
I am having a problem when running devfsadm. We have many T2000, but on one of them, that is connected to our SAN, devfsadm reports no new disks. If a reconfiguration reboot is done, the system reports the new disk. But only with a reboot. We have Solaris10 installed and Veritas... (13 Replies)
Hi,
I have a netra t2000 running solaris 10. It is fully patched with the latest patch cluster and also patch 118833-36 and 126897-02. The SC sys_event level is set to 3.
I am running a test to show hardware log status, e.g simulating a power supply failure.Hence I unplug one of te... (3 Replies)
Hi All
I have a problem on T2000 server.
bash-3.00# uname -a
SunOS 5.10 aaa Generic_120011-14 sun4v sparc SUNW,Netra-T2000After the initial solaris installation server failed to boot:
Rebooting with command: boot
Boot device: disk:b File and args:
The file just loaded does not appear... (1 Reply)
Hi all,
First post so be gentile :)
It's my first time installing Solaris on T2000 server.
I have 2 72GB HD's on it.
After configuring HW raid and running raidctl command I get this output:
bash-3.00# raidctl -l c0t0d0
Volume Size Stripe Status Cache RAID
... (2 Replies)
hi all
when i trying to give auto-boot value as false as following
#eeprom auto-boot?=false
it is showing as
zsh: no matches found: auto-boot?=false
so felt this is because of error in hard ware so i tried this
#iostat -en
it is showing like
iostat -en
---- errors ---
s/w h/w trn... (4 Replies)
Hi Friends,
I need a help from you all.
In my machine which is on Solaris 9.
the command prtdiag -v shows the complete output but it doesn't show "Memory Module Groups status" status.
I have tried restarting the picl daemon, but still it doesn't work.
Memory Module Groups:... (2 Replies)
Hi everyone,
Please can you tell me what kind of memro we are talking about when we run :
prtdiag -v
Memory size: 98016 Megabytes
Thank you (7 Replies)
selected lines from the output of the "prtdiag -v" command on a T5240 SUN server running Solaris 10.
Are the following known as FRU names and what do they mean?
MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
SYS/FANBD0/FM0/F0
SYS/FANBD0/FM0/F1
SYS/MB/CMP0/BR1/CH0/D1 ... (1 Reply)