Operating Systems Solaris IPMP config Post 302262099 by kumarmani on Wednesday 26th of November 2008 10:37:55 AM
Old 11-26-2008
Yes, its going to work in Multiusermode as svcadm command is there to manage the Solaris management facility services.
 

10 More Discussions You Might Find Interesting

1. Solaris

IPMP/zones config how for this case ,urgent

Hi I am setting up a test server for actual 2 node servers which will be behind load balancer. I will not be using sun cluster at all. The test machine is installed with solaris 10. I am not sure how to setup a test env of 2 nodes on only 1 node..may be creating 2 zones on test server will... (8 Replies)
Discussion started by: upengan78
8 Replies

2. Solaris

Ipmp

Hi All, Kindly help me in configuring IPMP or guid me to some link, tried goggling however no luck. Thanks in anticipation (1 Reply)
Discussion started by: kumarmani
1 Replies

3. Solaris

IPMP questions

Probe-based IPMP active - active Probe-based IPMP active - passive Link-based only active -standby ???? What are differences between Probe-based IPMP active - passive anddd Link-based only active -standby ???!!! For example in active active probe-based IPMP there are lets... (6 Replies)
Discussion started by: samar
6 Replies

4. Shell Programming and Scripting

parsing config file to create new config files

Hi, I want to use a config file as the base file and parse over the values of country and city parameters in the config file and generate separate config files as explained below. I will be using the config file as mentioned below: (config.txt) country:a,b city:1,2 type:b1... (1 Reply)
Discussion started by: clazzic
1 Replies

5. Solaris

ipmp testing

Please tell me how to configure IPMP in vmware what is the basic working concept of IPMP. please help me (1 Reply)
Discussion started by: sijocg
1 Replies

6. Solaris

IPMP problem

Hi all i had two interface ce0 and ce5 but when i run the ifconfig, it show me alot of extra virtual interface, may i know how to remove it? # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 ce0:... (2 Replies)
Discussion started by: SmartAntz
2 Replies

7. Shell Programming and Scripting

Shell script that will compare two config files and produce 2 outputs 1)actual config file 2)report

Hi I am new to shell scripting. There is a requirement to write a shell script to meet follwing needs.Prompt reply shall be highly appreciated. script that will compare two config files and produce 2 outputs - actual config file and a report indicating changes made. OS :Susi linux ver 10.3. ... (4 Replies)
Discussion started by: muraliinfy04
4 Replies

8. Solaris

Solaris IPMP

Can any one please explain me the concept behind IPMP in solaris clustering.Basic explanation would be really appreciated... Thanks in Advance vks (2 Replies)
Discussion started by: vks47
2 Replies

9. Solaris

Can't login using ssh after IPMP config.

Dear All, After configuring IPMP in 2 fresh Servers (T5520 and T2000) I can't login in any of them using SSH, I can login by serial console then I had to enable Telnet to access. IPMP works fine. This is the error in /var/adm/messages: sshd: Failed password for lvalle from 172.28.12.95 port... (0 Replies)
Discussion started by: Luis Valle
0 Replies

10. Red Hat

Apache virtual host config vs global config problem

Hi folks, I am trying to configure Apache webserver and also a virtual host inside this webserver. For Global server config: /var/www/html/index.html For virtual host config: /var/www/virtual/index.html Both client10 & www10 are pointing to 192.168.122.10 IP address. BUT, MY... (1 Reply)
Discussion started by: freebird8z
1 Replies
rpc.metad(1M)						  System Administration Commands					     rpc.metad(1M)

NAME
rpc.metad - remote metaset services SYNOPSIS
/usr/sbin/rpc.metad DESCRIPTION
rpc.metad is an rpc(4) daemon (functioning as a server process) that is used to manage local copies of metadevice diskset information. The rpc.metad daemon is controlled by inetadm(1M). EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), inetadm(1M), inetd(1M), metaset(1M), rpc.metamhd(1M), svcadm(1M), rpc(3NSL), services(4), attributes(5), smf(5) NOTES
The rpc.metad service is managed by the service management facility, smf(5), under the service identifier: svc:/network/rpc/meta:default Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). Responsibil- ity for initiating and restarting this service is delegated to inetd(1M). Use inetadm(1M) to make configuration changes and to view config- uration information for this service. The service's status can be queried using the svcs(1) command. SunOS 5.11 4 Nov 2004 rpc.metad(1M)
All times are GMT -4. The time now is 09:21 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy