Regularly on SANs theres microcode upgrade with disruption of one fiber...
To not suffer disruption you usually use 2 HBA through 2 separate paths...
Your internal drives are HW raid/mirror with spare or software?
If software when disks go wrong usually it sends reset SCSI signals which affect the others diversely...
For safety I would go with 2 new HBAs...

All the best
 

10 More Discussions You Might Find Interesting

1. Solaris

HBA Card

Hello...I got a problem here. I have HBAs installed in one of the domains in E20 and I gotta find out the brand and firmware. But when I do a prtconf, I cannot see the HBA. For other servers installed with HBAs, when I do prtconf on them I can see either qlc or em. Can you guys enlighten me how to... (5 Replies)
Discussion started by: xiaochensg
5 Replies

2. Solaris

Qlogic HBA card in E450 with errors

I have installed a qlogic HBA card in an E450 Solaris 9 with all the SUNW packages and the latest EPROM version. Configuration reboot was done. An orange light flashes to the right of where the card plugs into the fiber cable after booting, and the following error apprears at the start of the boot... (9 Replies)
Discussion started by: floydm
9 Replies

3. Solaris

istall sas raid HBA internal card

I need to install a raid HBA internal card on a T5240. The reason is I have more drives and the current mother board controller does not support more than 4 drives. My question is I have raidctl set up on current drives. If I install new HBA card do I have to delete current raidctl and... (3 Replies)
Discussion started by: photon
3 Replies

4. Solaris

Install Solaris 10 with an internal StorageTek SAS HBA Raid card

Hi all i would like to ask some suggests about my next job! I have to install a new Sun Netra T5220, with an additional internal StorageTek SAS HBA Raid. The problem come in if every disk is now controlled by the HBA, how can I install the OS? No disk is being detected by the OS. SAS card... (2 Replies)
Discussion started by: kakabobo
2 Replies

5. AIX

Need HBA card driver

Hi All, SUN emulex HBA card has been installed on P520 box. When i run the cfgmgr i am getting the following message. lpar2#cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed.... (0 Replies)
Discussion started by: b_manu78
0 Replies

6. Solaris

installing solaris with StorageTek SAS RAID Internal HBA

i was given a task which needs to perform a raid 1 on the boot disk, and 4 other disks on raid 10. Is there any other alternative in installing solaris 10 other than through network installation?will be using solaris update 6. while reading through the user guide i got pretty confuse. ... (1 Reply)
Discussion started by: monstar1407
1 Replies

7. Solaris

How to enable hba port of a two port hba card

Hi, i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port. ---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ---------- please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies

8. Solaris

Extracting HBA Card Hardware info

Hello, I am very new to solaris so please bear with me. I have 2 machines in question. For both I am trying to get the HBA Card Hardware information such as: HBA Model Name HBA Firmware version HBA Port details HBA Driver details First machine is a Solaris 10. When I execute fcinfo... (6 Replies)
Discussion started by: flagman5
6 Replies

9. Solaris

Which FC HBA card support Solaris9

I have JNI FCE-6460-N fc card , it is detected in OK prompt.....I connected Sun StorEDGE A5000 FC storage. in OK prompt, PROBE-SCSI-ALL showing A5000 fc hdds details in ok prompt..... but in OS level.....not showing the hdd, i tried in DEVFSADM command and FORMAT command not showing A5000... (3 Replies)
Discussion started by: anysystem
3 Replies

10. Red Hat

HBA card faulty

Hi, How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies
raidtab(5)							File Formats Manual							raidtab(5)

NAME
raidtab - configuration file for md (RAID) devices DESCRIPTION
/etc/raidtab is the default configuration file for the raid tools (raidstart and company). It defines how RAID devices are configured on a system. FORMAT
/etc/raidtab has multiple sections, one for each md device which is being configured. Each section begins with the raiddev keyword. The order of items in the file is important. Later raiddev entries can use earlier ones (which allows RAID-10, for example), and the parsing code isn't overly bright, so be sure to follow the ordering in this man page for best results. Here's a sample md configuration file: # # sample raiddev configuration file # 'old' RAID0 array created with mdtools. # raiddev /dev/md0 raid-level 0 nr-raid-disks 2 persistent-superblock 0 chunk-size 8 device /dev/hda1 raid-disk 0 device /dev/hdb1 raid-disk 1 raiddev /dev/md1 raid-level 5 nr-raid-disks 3 nr-spare-disks 1 persistent-superblock 1 parity-algorithm left-symmetric device /dev/sda1 raid-disk 0 device /dev/sdb1 raid-disk 1 device /dev/sdc1 raid-disk 2 device /dev/sdd1 spare-disk 0 Here is more information on the directives which are in raid configuration files; the options are listen in this file in the same order they should appear in the actual configuration file. raiddev device This introduces the configuration section for the stated device. nr-raid-disks count Number of raid devices in the array; there should be count raid-disk entries later in the file. (current maximum limit for RAID devices -including spares- is 12 disks. This limit is already extended to 256 disks in experimental patches.) nr-spare-disks count Number of spare devices in the array; there should be count spare-disk entries later in the file. Spare disks may only be used with RAID4 and RAID5, and allow the kernel to automatically build new RAID disks as needed. It is also possible to add/remove spares run- time via raidhotadd/raidhotremove, care has to be taken that the /etc/raidtab configuration exactly follows the actual configuration of the array. (raidhotadd/raidhotremove does not change the configuration file) persistent-superblock 0/1 newly created RAID arrays should use a persistent superblock. A persistent superblock is a small disk area allocated at the end of each RAID device, this helps the kernel to safely detect RAID devices even if disks have been moved between SCSI controllers. It can be used for RAID0/LINEAR arrays too, to protect against accidental disk mixups. (the kernel will either correctly reorder disks, or will refuse to start up an array if something has happened to any member disk. Of course for the 'fail-safe' RAID variants (RAID1/RAID5) spares are activated if any disk fails.) Every member disk/partition/device has a superblock, which carries all information necessary to start up the whole array. (for autodetection to work all the 'member' RAID partitions should be marked type 0xfd via fdisk) The superblock is not visible in the final RAID array and cannot be destroyed accidentally through usage of the md device files, all RAID data content is available for filesystem use. parity-algorithm which The parity-algorithm to use with RAID5. It must be one of left-asymmetric, right-asymmetric, left-symmetric, or right-symmetric. left-symmetric is the one that offers maximum performance on typical disks with rotating platters. chunk-size size Sets the stripe size to size kilobytes. Has to be a power of 2 and has a compilation-time maximum of 4M. (MAX_CHUNK_SIZE in the ker- nel driver) typical values are anything from 4k to 128k, the best value should be determined by experimenting on a given array, alot depends on the SCSI and disk configuration. device devpath Adds the device devpath to the list of devices which comprise the raid system. Note that this command must be followed by one of raid-disk, spare-disk, or parity-disk. Also note that it's possible to recursively define RAID arrays, ie. to set up a RAID5 array of RAID5 arrays. (thus achieving two-disk failure protection, at the price of more disk space spent on RAID5 checksum blocks) raid-disk index The most recently defined device is inserted at position index in the raid array. spare-disk index The most recently defined device is inserted at position index in the spare disk array. parity-disk index The most recently defined device is moved to the end of the raid array, which forces it to be used for parity. failed-disk index The most recently defined device is inserted at position index in the raid array as a failed device. This allows you to create raid 1/4/5 devices in degraded mode - useful for installation. Don't use the smallest device in an array for this, put this after the raid-disk definitions! NOTES
The raidtools are derived from the md-tools and raidtools packages, which were originally written by Marc Zyngier, Miguel de Icaza, Gadi Oxman, Bradley Ward Allen, and Ingo Molnar. SEE ALSO
raidstart(8), raid0run(8), mkraid(8), raidstop(8) raidtab(5)
All times are GMT -4. The time now is 08:04 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy