Sponsored Content
Full Discussion: 3600 C Class disk upgrade
Operating Systems HP-UX 3600 C Class disk upgrade Post 302250731 by Freddo_21 on Friday 24th of October 2008 06:49:49 AM
Old 10-24-2008
3600 C Class disk upgrade reply

Hi DustBunny

The system is running HP-UX 11.23 - and I have the original disk kit and I don't mind re-installing the OS - there's no data on it to worry about

The system can be started up with no trouble - I just don't leave it running all the time.

Yes - I want to change the root disk. There's 2 x 9GB disks in there and I would like to replace both of them.

The disks are internal on a SCA connector - and from the look of the easy access disk caddy, I think the disk is supposed to be hot swappable.

The system is a workstation, so I am not worried about hot swappable servers

It's a home / hobby system in the garage, so no need to worry about volume management or RAID

Hope this helps a bit ..


Freddy
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Upgrade Hard Disk to a larger one

Hello folks, I have a sun sparcstation 20, I would like to upgrade one of the hard disks to a larger one. The one I would like to upgrade only contains user data. Here are my thoughts: 1. Backup the specific file system 2. Replace the disk with the larger disk 3. Create a new file... (2 Replies)
Discussion started by: DLongan
2 Replies

2. AIX

Disk upgrade problem

I've tried to upgrade the 9gb drives in our F50's to 18gb. The system with original drives would boot up in about 4 min., but with the 18gb drives takes 17 min. Running 4.2.1. What am I missing here?? (5 Replies)
Discussion started by: mooshkie
5 Replies

3. UNIX for Advanced & Expert Users

3600 tcp/udp, trap-daemon, text relay-answer

3600 tcp/udp, trap-daemon, text relay-answer Does anyone know what this service is responsible for, or how significant it is? Thanks.....James (1 Reply)
Discussion started by: cassj
1 Replies

4. UNIX for Advanced & Expert Users

disk upgrade

Hi all, this s going to be my 1st time upgrading a disk.I need the ways or steps to migrate data from a 2gb disk to a 4gb disk which sits in the High Availability Disk Array Model 10.the os disk is the internal disk of the K200 system so i dont think i would be meddling around with that.what r... (1 Reply)
Discussion started by: giriplug
1 Replies

5. Solaris

Upgrade disk in RAID 1

I need to upgrade 2 x 73 GB disk and replace with 2 x 146 GB disk in sun v240. These disks contain boot and swap files These are mirrored disks with RAID 1 I am trining to create the correct procedure. So far the procedure I have is as follows: # metastat State: Okay ... (5 Replies)
Discussion started by: photon
5 Replies

6. UNIX for Dummies Questions & Answers

How to 'split' mirror disk for OS upgrade purpose

Plan to upgrade Solaris from version 8 to version 9. Understand that if the boot disk is mirrored, I need to split it first before upgrade, how can I do that? Please advise. Thank you. (2 Replies)
Discussion started by: KhawHL
2 Replies

7. UNIX for Advanced & Expert Users

Get pointer for existing device class (struct class) in Linux kernel module

Hi all! I am trying to register a device in an existing device class, but I am having trouble getting the pointer to an existing class. I can create a class in a module, get the pointer to it and then use it to register the device with: *cl = class_create(THIS_MODULE, className);... (0 Replies)
Discussion started by: hdaniel@ualg.pt
0 Replies

8. Programming

Size of Derived class, upon virtual base class inheritance

I have the two class definition as follows. class A { public: int a; }; class B : virtual public A{ }; The size of class A is shown as 4, and size of class B is shown as 16. Why is this effect ?. (2 Replies)
Discussion started by: techmonk
2 Replies

9. Programming

C++ : Base class member function not accessible from derived class

Hello All, I am a learner in C++. I was testing my inheritance knowledge with following piece of code. #include <iostream> using namespace std; class base { public : void display() { cout << "In base display()" << endl; } void display(int k) {... (2 Replies)
Discussion started by: anand.shah
2 Replies

10. Solaris

How to use live-upgrade with single disk, pre-patching steps?

Hi, I have Solaris-10 x86 (running on HP hardware), with 12 non-global zones running on this. I have to install latest patch cluster/set on this server. This server is not under backup schedule, so before installing patch cluster, I want to keep a backup. In case of any issue (bad patch or... (4 Replies)
Discussion started by: solaris_1977
4 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)
All times are GMT -4. The time now is 02:01 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy