08-06-2008
Are you sure it's even possible with D1000s? Unfortunately I no longer have current SunSolve access to check... If I recall there was only one DIP switch to change to set it to either full or half access. If it is possible, keep in mind that you will most likely need to change the scsi-initiator-id (in the EEPROM) to a different value on one of the servers. Default is 7, change one of them to 15 I guess... that way the SCSI bus will know the difference between the two sources of I/O requests.
10 More Discussions You Might Find Interesting
1. Programming
Hi !
Please tell me how to get radio buttons, text boxes , check boxes , option buttons , pull down menus in C++ on Unix.
I think it would be done using curses.h ..but that's all i know.
TIA,
Devyani. (3 Replies)
Discussion started by: devy8
3 Replies
2. UNIX for Advanced & Expert Users
Hi,
I have an application which must use a unified database, the application will run on 4 SCO boxes, so the database will be in one of them and the application in the other 3 servers will access this database on the host machine. This is as a file sharing application in windows. I know this... (0 Replies)
Discussion started by: BAM
0 Replies
3. IP Networking
I have RedHat 9.0 installed on three of my servers (PIII - 233MHz) and want that they share a common IP address so that any request made reaches each of the servers.
Can anyone suggest how should I setup my LAN. I'm new to networking in Linux so please elaborate and would be thankful for a timely... (2 Replies)
Discussion started by: Rakesh Ranjan
2 Replies
4. Solaris
Hi folks,
I´m having a problem with a Ultra60 box with diff scsi pci card
conected to one D1000. The conection are correct because a checked the
D1000 guide. When a do probe-scsi-all in the OBP, the D1000 blink all
disks one time then the led of one of the disks powers off and then
nothing... (2 Replies)
Discussion started by: spacewalker
2 Replies
5. Solaris
Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000"
the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies
6. UNIX for Advanced & Expert Users
Hi All,
Is there anyway two nodes can share D1000 or minipack with 6 disk slots.
Right now I have minipacks and I am connecting to Sunblade 100 and Sunbladew 150 separately. I would like to connect two systems to one minipack and able see the all the disks on both systems.
I do have D1000... (0 Replies)
Discussion started by: sriny
0 Replies
7. Solaris
Hi Community,
could you provide me a procedure or solaris 10 tool/command or Veritas command to check ths Storedge IP?
Thank you!!! (4 Replies)
Discussion started by: Sunb3
4 Replies
8. Solaris
Hi,
Recently i was trying to connect Sun Storedge D1000 Array to E420 R (Practice servers). I connected the SCSI cable between array and server. I tried the following :
#devfsadm (nothing showed up)
#format (no new disk is shown here)
i tried this process again after putting ON the... (2 Replies)
Discussion started by: bluegold86
2 Replies
9. Solaris
Hi.
I need to move a 5 disk RAID5 array from a SE3310 box to a different SE3310 array. After installing the disks in the "new" StorEdge device, I "would like" ;) to be able have access to the data which is on the RAID.
Essentially, the quesion is, how can this be done? :confused:
I checked... (5 Replies)
Discussion started by: alexs77
5 Replies
10. Solaris
I am trying to connect D1000 storedge with my sun blade 1500 and i am getting the following error when booting the system.
Oct 13 22:21:56 brampton rpcbind: rpcbind terminating on signal.
Oct 13 22:22:02 brampton syseventd: SIGHUP caught - reloading modules
Oct 13 22:22:02 brampton... (9 Replies)
Discussion started by: mnathan
9 Replies
vxpfto(1M) vxpfto(1M)
NAME
vxpfto - set Powerfail Timeout (pfto)
SYNOPSIS
vxpfto -g diskgroup -t timeout
vxpfto [-g diskgroup] -t timeout volume_list
vxpfto [-g diskgroup] -o pftostate={enabled|disabled}
vxpfto [-g diskgroup] -o pftostate={enabled|disabled} volume_list
DESCRIPTION
Powerfail Timeout is an attribute of a SCSI disk connected to an HP-UX host (see the pfto(7) man page). The vxpfto command sets the Power-
fail Timeout interval on a set of Volume Manager disks, either all disks in a disk group, or all disks underlying the volumes listed.
The first form of the command sets the same PFTO value for all the disks in the specified VxVM diskgroup.
In the second form, all disks underlying the given list of volumes are selected, optionally restricted by the disk group specified with the
-g option. If you specify a diskgroup, any volume in the list not belonging to the diskgroup is ignored.
Use the -o pftostate option to disable or enable PFTO. By default, PFTO is enabled. You can enable PFTO either on all disks in a disk
group, or on all disks underlying the volumes listed.
If you invoke vxpfto without arguments, it displays a usage message.
OPTIONS
-g diskgroup
Specifies the disk group for the operation, either by disk group ID or by disk group name.
-o pftostate={enabled|disabled}
Enables or disables the use of PFTO for IO.
-t timeout
Specifies the PFTO value in seconds. The value must be zero or a positive integer. Zero represents the system default PFTO
value. The default value depends on the disk driver controlling the disk device.
volume_list
A list of VxVM volume names. List items must be separated by white-space.
EXIT CODES
vxpfto returns a zero if successful. If it encounters an error, vxpfto exits and displays a message on standard error. Defined exit codes
are:
0 Success.
1 No PFTO value specified.
2 No diskgroup or volume list specified.
3 Illegal PFTO value specified.
EXAMPLES
Set the PFTO value on all disks in disk group testdg to 100 seconds:
vxpfto -t 100 -g testdg
Set the PFTO value to 50 seconds on all disks underlying volume01 and volume02 in disk group testdg:
vxpfto -t 50 -g testdg volume01 volume02
Set the PFTO value to 300 seconds on all disks underlying volume01 and volume02, even though they are not in the same disk group:
vxpfto -t 300 volume01 volume02
Disable PFTO on all disks in disk group testdg:
vxpfto -g testdg -o pftostate=disabled
Enable PFTO on all disks underlying volume01 and volume02i in disk group testdg:
vxpfto -g testdg -o pftostate=enabled volume01 volume02
SEE ALSO
vxdisk(1M), pfto(7)
VxVM 5.0.31.1 24 Mar 2008 vxpfto(1M)