Sponsored Content
Top Forums UNIX for Advanced & Expert Users Communicating with Serial Port Post 302175521 by netsavant on Friday 14th of March 2008 09:13:06 AM
Old 03-14-2008
my system has minicom 2 version. I had openend minicom and configured it to 9600 8N1 and restarted it. but it is showing offline. Pls hlp. How can i call this minicom from PHP code.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

serial port configuration

I am having trouble with a device connected through a serial port on my sun workstation ( I am running solaris 7). The seriel device works on an identical workstation running the same o/s version but when I move it to the initial workstation it doesn't work. I am using an rs232 serial cable and... (1 Reply)
Discussion started by: Henrik
1 Replies

2. Programming

Telling apart serial from // port

I'm writing a journal_write() function and I want it to: - be a possible drop in replacement for write() - write entries to the journal ;-) Could be a regular file (journal.txt), a serial printer or a // printer. - handle printer status if needed. fstat() tells weather or not we're dealing with... (2 Replies)
Discussion started by: starless
2 Replies

3. Solaris

Serial Port Datalogger

Hi, I'm using Solaris workstation with 5.4 OS. I was wondering if there's a way that I could log the data incoming and outgoing on a certain serial port. Thanks in Advance! (1 Reply)
Discussion started by: uryuu
1 Replies

4. Solaris

Serial port issue

Hi, I am working with Sun Solaris 9 Sparc,Sun-Blade-100.In my application,I need to monitor the UPS using Serial port. When I am using JRE 1.4 in my application,I am able to monitor it but when I am upgrading the JRE version from 1.4 to JRE1.6. I am not able to monitor the UPS.It is showing the... (1 Reply)
Discussion started by: smartgupta
1 Replies

5. Programming

Programming serial port

Hello! Can someone advice me which method I will use if I want to communicate with device via RS232 serial port with this requirements: 1. Serial port is opened in non-canonical mode. 2. All the time I need to check is there something to read. 3. If I have to write something I need to write it... (6 Replies)
Discussion started by: jvrlic
6 Replies

6. AIX

how to know my serial port is communicating and running fine

i want to know that my serial port ( pci slot with 2 port ) is working fine and communicating is there any way to know the serialport is working and communicating? please help (3 Replies)
Discussion started by: pchangba
3 Replies

7. Shell Programming and Scripting

Need help with serial port

Hi, I have a external board connected to my serial port. I need to execute "shutdown -r now" command when system boot up. When system boots up it requires a username ans password. Then I need to run my command. I can use rc script but that is rebooting system before it asks for username and... (0 Replies)
Discussion started by: charlie.arya
0 Replies

8. Solaris

How to enable Serial port on ILOM, when Network Port is enabled in parallel

Hi Everyone, In my environment, I have few T5220. On the iLOM Management Card, I have both Network and Serial port are cabled, I don't have any issues while I try to connect using Network Management port, but when I try to connect the serial port for the same server which is actually connected... (3 Replies)
Discussion started by: bobby320
3 Replies

9. Solaris

Cabling and adapters to communicate to service processor serial port from Windows PC with USB port.

Hello, I have an unloaded T5140 machine and want to access the ILOM for the first time and subsequently the network port after that., and then load Solaris 10 the final January 2011 build. The first part is what confuses me -the cabling. I am coming from a Windows machine (w/appropriate... (5 Replies)
Discussion started by: joboy
5 Replies

10. Shell Programming and Scripting

Communicating with ethernet to serial LED sign - is this feasible?

I have a london-electronics LED sign I picked up on eBay which I would like to display custom messages on programmatically. It is working ok. Opening it up, it has an ethernet to serial connection currently plugged in and a serial connection currently unplugged internally (same connectors).... (9 Replies)
Discussion started by: windswept321
9 Replies
RUNSCRIPT(1)						      General Commands Manual						      RUNSCRIPT(1)

NAME
runscript - script interpreter for minicom SYNOPSIS
runscript scriptname [logfile [homedir]] DESCRIPTION
runscript is a simple script interpreter that can be called from within the minicom communications program to automate tasks like logging in to a Unix system or your favorite BBS. INVOCATION
The program expects a script name and optionally a filename and the user's home directory as arguments, and it expects that it's input and output are connected to the "remote end", the system you are connecting to. All messages from runscript meant for the local screen are directed to the stderr output. All this is automatically taken care of if you run it from minicom. The logfile and home directory parame- ters are only used to tell the log command the name of the logfile and where to write it. If the homedir is omitted, runscript uses the directory found in the $HOME environment variable. If also the logfile name is omitted, the log commands are ignored. KEYWORDS
Runscript recognizes the following commands: expect send goto gosub return ! exit print set inc dec if timeout verbose sleep break call log OVERVIEW OF KEYWORDS
send <string> <string> is sent to the modem. It is followed by a ' '. <string> can be: - regular text, e.g. 'send hello' - text enclosed in quotes, e.g. 'send "hello world"' Within <string> the following sequences are recognized: - newline - carriage return a - bell  - backspace c - don't send the default ' '. f - formfeed ^ - the ^ character o - send character o (o is an octal number) Control characters can be used in the string with the ^ prefix (^A to ^Z, ^[, ^ ^], ^^ and ^_). If you need to send the ^ character, you must prefix it with the escape character. Also $(environment_variable) can be used, for example $(TERM). Minicom passes three special environment variables: $(LOGIN), which is the username, $(PASS), which is the password, as defined in the proper entry of the dialing directory, and $(TERMLIN) which is the number of actual terminal lines on your screen (that is, the statusline excluded). print <string> Prints <string> to the local screen. Default followed by ' '. See the description of 'send' above. label: Declares a label (with the name 'label') to use with goto or gosub. goto <label> Jump to another place in the program. gosub <label> Jumps to another place in the program. When the statement 'return' is encountered, control returns to the statement after the gosub. Gosub's can be nested. return Return from a gosub. ! <command> Runs a shell for you in which 'command' is executed. On return, the variable '$?' is set to the exit status of this command, so you can subsequently test it using 'if'. exit [value] Exit from "runscript" with an optional exit status. (default 1) set <variable> <value> Sets the value of <variable> (which is a single letter a-z) to the value <value>. If <variable> does not exist, it will be created. <value> can be a integer value or another variable. inc <variable> Increments the value of <variable> by one. dec <variable> Decrements the value of <variable> by one. if <value> <operator> <value> <statement> Conditional execution of <statement>. <operator> can be <, >, != or =. Eg, 'if a > 3 goto exitlabel'. timeout <value> Sets the global timeout. By default, 'runscript' will exit after 120 seconds. This can be changed with this command. Warning: this command acts differently within an 'expect' statement, but more about that later. verbose <on|off> By default, this is 'on'. That means that anything that is being read from the modem by 'runscript', gets echoed to the screen. This is so that you can see what 'runscript' is doing. sleep <value> Suspend execution for <value> seconds. expect expect { pattern [statement] pattern [statement] [timeout <value> [statement] ] .... } The most important command of all. Expect keeps reading from the input until it reads a pattern that matches one of the specified ones. If expect encounters an optional statement after that pattern, it will execute it. Otherwise the default is to just break out of the expect. 'pattern' is a string, just as in 'send' (see above). Normally, expect will timeout in 60 seconds and just exit, but this can be changed with the timeout command. break Break out of an 'expect' statement. This is normally only useful as argument to 'timeout' within an expect, because the default action of timeout is to exit immediately. call <scriptname> Transfers control to another scriptfile. When that scriptfile finishes without errors, the original script will continue. log <text> Write text to the logfile. NOTES
If you want to make your script to exit minicom (for example when you use minicom to dial up your ISP, and then start a PPP or SLIP session from a script), try the command "! killall -9 minicom" as the last script command. The -9 option should prevent minicom from hanging up the line and resetting the modem before exiting. Well, I don't think this is enough information to make you an experienced 'programmer' in 'runscript', but together with the examples it shouldn't be too hard to write some useful script files. Things will be easier if you have experience with BASIC. The minicom source code comes together with two example scripts, scriptdemo and unixlogin. Especially the last one is a good base to build on for your own scripts. SEE ALSO
minicom(1) BUGS
Runscript should be built in to minicom. AUTHOR
Miquel van Smoorenburg, <miquels@drinkel.ow.org> Jukka Lahtinen, <walker@netsonic.fi> User's Manual $Date: 2007-10-07 18:13:51 $ RUNSCRIPT(1)
All times are GMT -4. The time now is 11:47 AM.