02-08-2002
Check that you have the option set to save the core.
Check dmesg for any errors.
Check /var/adm/messages (or wherever you send messages) for errors - errors should be right before the reboot messages start
Ask yourself, your team, your IS staff if anyone changed anything.
Use /usr/platform/sun4u/sbin/prtdiag -v and look for errors.
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi
I faced a problem while booting linux which is as follows;-
*************************************************
Inode 146180 has illegal block(s)
xauth:error in locking authority file /home/root/.Xauthority
Fatal Server Error:
Could not create lock file in /tmp/tXo-lock
... (1 Reply)
Discussion started by: Abhishek
1 Replies
2. UNIX for Advanced & Expert Users
We have had a server (Solaris 2.6) hardisk crash. When booting the server we get:
ok> boot -S
Boot Device: /sbus/espdmc@e, 8400000/esp@e,8800000/sd@0,0
short read 0x2000 chars read
disk read error
The only way we can get into the console is to
ok> boot cdrom
whereby everything (e.g.... (3 Replies)
Discussion started by: Breen
3 Replies
3. HP-UX
hi friends,
i know that when there is a crash then that memory image is
put into /var/adm/crash
but if the system hangs up and if i have access to console of
that machine then how can i take the crash dump manully.
thanks (2 Replies)
Discussion started by: mxms755
2 Replies
4. Linux
Is it true that you can't have the crash dump server/client on the same server?
I know I've installed Nagios open source before, I though it's only for that kind of thing. I never though that Red hat ent 4 would be like client/server on the crash dump.
if someone is having problem with high... (0 Replies)
Discussion started by: itik
0 Replies
5. Programming
Problem
- Linux Client/Server Socket Application: Preventing Client from quitting on server crash
Hi,
I am writing a Linux socket Server and Client using TCP protocol on Ubuntu 9.04 x64.
I am having problem trying to implement a scenario where the client should keep running even when the... (2 Replies)
Discussion started by: varun.nagpaal
2 Replies
6. Red Hat
Hello Folks,
My RHEL 4.3 server got crashed due to hardware crash,system hard disk and motherboard replaced and RAID rebuilt done.
while rebooting the server the server is gone into single user mode due to /sda5 var partition not able to mount.
Error :- " wrong fs type, bad... (1 Reply)
Discussion started by: kmvinay
1 Replies
7. SCO
Hi there.
Well i have a really bad problem with my server:
UnixWare Version 5 Release 7
The system crash :wall: and show the error:
Panic: Kernel-mode address fault on user address 0x00000004 :eek:
If anyone knows about the reason of this error please give me a help
Sorry by my english.... (3 Replies)
Discussion started by: danilosevilla
3 Replies
8. Programming
The steps to test the problem
1. Open TCP Server
2. Open TCP Client
3. TCP Client sends data to Server.
4. Close TCP Server and the client also crash without any notification
Second wonderful test:
1. Comment the following statement in Client.c (at line 168) and compile it
Writen(... (1 Reply)
Discussion started by: sehang
1 Replies
9. Red Hat
hi,
i would like to configure netdump, but saving the var/crash in the server itself, not in another server.
could anybody tell me if this is possible?
thanks (4 Replies)
Discussion started by: pabloli150
4 Replies
10. UNIX for Dummies Questions & Answers
Environmnet: HP-UX B.11.31 U ia64
RDBMS: Oracle Database 11g Enterprise Edition Release 11.2.0.3.0 - 64bit Production
Question:
When server hangs or node evicts, we open up tickets with Oracle Support and Oracle Support ask for some list of log files.
Currently we can not use the... (2 Replies)
Discussion started by: Siva SQL
2 Replies
LEARN ABOUT MINIX
prtdiag
prtdiag(1M) prtdiag(1M)
NAME
prtdiag - display system diagnostic information
SYNOPSIS
/usr/sbin/prtdiag [-v] [-l]
prtdiag displays system configuration and diagnostic information on sun4u and sun4v systems.
The diagnostic information lists any failed field replaceable units (FRUs) in the system.
The interface, output, and location in the directory hierarchy for prtdiag are uncommitted and subject to change in future releases.
prtdiag does not display diagnostic information and environmental status when executed on the Sun Enterprise 10000 server. See the
/var/opt/SUNWssp/adm/${SUNW_HOSTNAME}/messages file on the system service processor (SSP) to obtain such information for this server.
The following options are supported:
-l Log output. If failures or errors exist in the system, output this information to syslogd(1M) only.
-v Verbose mode. Displays the time of the most recent AC Power failure, and the most recent hardware fatal error information, and (if
applicable) environmental status. The hardware fatal error information is useful to repair and manufacturing for detailed diagnos-
tics of FRUs.
The following exit values are returned:
0 No failures or errors are detected in the system.
1 Failures or errors are detected in the system.
2 An internal prtdiag error occurred, for example, out of memory.
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWkvm |
+-----------------------------+-----------------------------+
|Interface Stability |Unstable* |
+-----------------------------+-----------------------------+
*The output is unstable.
modinfo(1M), prtconf(1M), psrinfo(1M), sysdef(1M), syslogd(1M), attributes(5), openprom(7D)
NOTES
Not all diagnostic and system information is available on every Solaris platforn, and therefore cannot be displayed by prtdiag. On those
platforms, further information can be obtained from the System Controller.
29 Aug 2005 prtdiag(1M)