Sponsored Content
Operating Systems AIX PowerHA HACMP on VIOS servers Post 302774759 by filosophizer on Sunday 3rd of March 2013 05:05:29 AM
Old 03-03-2013
IBM PowerHA HACMP on VIOS servers

Few questions regarding Power HA ( previously known as HACMP) and VIOS POWERVM IVM ( IBM Virtualization I/O Server )

[1] Is it possible to create HACMP cluster between two VIOS servers

Physical Machine_1
VIOS_SERVER_1
LPAR_1
SHARED_DISK_XX


VIOS_SERVER_2
Physical Machine_2
LPAR_2
SHARED_DISK_XX

In this scenario, You will have to assign the shared disk first to the VIOS server and from there it will be assigned to LPAR.

Would HACMP work on this shared disk ?



[2] Can you have DLPAR ( Dynamic LPAR ) capabilities in IVM , that is assign one physical Fiber Adapter card to LPAR directly ? IVM VIOS ( which is you are running VIOS without HMC = Hardware Management Console )



in this scenario, you can give the LPAR , shared disk directly from the Storage ? ( provided feature is supported ?! )

[3] DO I need HMC for NPIV or can it run on IVM only ?

What is NPIV?
N_Port ID Virtualization(NPIV) is a standardized method for virtualizing a physical fibre channel port. An NPIV-capable fibre channel HBA can have multiple N_Ports, each with a unique identity. NPIV coupled with the Virtual I/O Server (VIOS) adapter sharing capabilities allow a physical fibre channel HBA to be shared across multiple guest operating systems. The PowerVM implementation of NPIV enables POWER logical partitions (LPARs) to have virtual fibre channel HBAs, each with a dedicated world wide port name. Each virtual fibre channel HBA has a unique SAN identity similar to that of a dedicated physical HBA.
The minimum requirement for the 8 Gigabit Dual Port Fibre Channel adapter, feature code 5735, to support NPIV is 110304
 

10 More Discussions You Might Find Interesting

1. AIX

Duplicate IP address makes PowerHA ( HACMP ) down

Hello, I would like to know if anyone has faced this problem. Whenever there is a duplicate IP address, HACMP goes down infact HACMP ( PowerHA ) takes the whole system down. Does anyone know how to solve this problem ? (3 Replies)
Discussion started by: filosophizer
3 Replies

2. AIX

HACMP does not start db2 after failover (db2nodes not getting modified by hacmp)

hi, when I do a failover, hacmp always starts db2 but recently it fails to start db2..noticed the issue is db2nodes.cfg is not modified by hacmp and is still showing primary node..manually changed the node name to secondary after which db2 started immediately..unable to figure out why hacmp is... (4 Replies)
Discussion started by: gkr747
4 Replies

3. AIX

Interoperability Oracle Clusterware - PowerHA/HACMP

I am planning for building a new database server using AIX 6.1 and Oracle 11.2 using ASM. As i have learned starting with Oracle 11.2 ASM can only be used in conjunction with Clusterware, which is Oracles HA-software. As is the companies policy we do intend to use PowerHA as HA-solution instead... (1 Reply)
Discussion started by: bakunin
1 Replies

4. AIX

Increase LUN size in AIX with VIOS and HACMP

Hello! I have this infraestructure: - 1 POWER7 with single VIOS on Site A. - 1 POWER6 with single VIOS on Site B. - 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A. - 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB. - 1 Storage DS4700 on Site A. - 1... (8 Replies)
Discussion started by: enzote
8 Replies

5. AIX

PowerHA Disk on VIO Server

Hello AIX GURU's Can anybody tell me the steps to crate shared VG (enhanced concurent) for my Lpars from VIO server? my questions are: 1. Should I crate Enhanced Concurent VG in VIO and map it using virtual Scsi to Lpar? or 2. Can I just create virtual SCSI in VIO and map to Lpar and... (1 Reply)
Discussion started by: Vit0_Corleone
1 Replies

6. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

7. AIX

PowerHA(HACMP) full vg loss - cluster hangs on release_vg_fs event

Hello, AIX 6.1 TL7 SP6 POwerHA 6.1 SP10 I was experimenting with new hacmp build. It's 3-node cluster build on AIX 6.1 lpars. It contains Ethernet and diskhb networks. Shared vg disk is SAN disk. Two nodes see disk using vscsi, third node sees disk using npiv. Application is db2 server. ... (4 Replies)
Discussion started by: vilius
4 Replies

8. AIX

Powerha on AIX 6.1.9

hello ive installed powerha 7.1.3 on two servers aix 6.1.9 6100-09-03-1415 work with dmx4 EMC storgae. after sync cluster ( terminate with OK ) ive see that the repository disk upper only in one machine : hdiskpower60 00c7f6b59fc60d9d caavg_private active... (1 Reply)
Discussion started by: ariec
1 Replies

9. AIX

VXVM in POWERHA 6.1

I have created a VxVM disk group in AIX7.1. I have tried to added this VxVM disk group in powerHA 6.1. But in cluster VxVM DGs are not listing. Is there any other procedure to add vxvm diskgroup to hacmp. Please share me steps for adding vxvm diskgroup to hacmp. (6 Replies)
Discussion started by: sunnybee
6 Replies

10. AIX

Upgrading PowerHA from 7.1.0 to 7.1.3

Hi All, As per the IBM upgrade/support matrix IBM Techdocs Technote: PowerHA for AIX Version Compatibility Matrix we can't do online upgrade or rolling migration from powerha v7.1.0 to v7.1.3. on AIX61_TL9_SP4, So we are following the steps as below ... 1 ) Bring down the cluster 2 )... (2 Replies)
Discussion started by: linux.amrit
2 Replies
scsimgr_fcd(7)						 Miscellaneous Information Manual					    scsimgr_fcd(7)

NAME
scsimgr_fcd - Fibre Channel interface driver fcd plug-in for scsimgr DESCRIPTION
The Fibre Channel interface driver plug-in for implements management operations specific to fibre channel HBA controllers bound to driver is the native HP-UX Fibre Channel interface driver that manages fibre channel devices. The plug-in handles the following operations for driver o Get, set and save per driver instance attributes. Commands The user can explicitly send the following commands to the driver plug-in by specifying the instance#> HBA controller hardware path> instance#> option: Displays information on attributes. Saves value of attributes in a persistent store. Sets values of attributes. Refer to scsimgr(1M) for the syntax of these commands. automatically invokes the plug-in to perform the driver specific part of the operation when the operation applies to per driver instances. Attributes The following table lists driver specific attributes. For details on the concept of attributes refer to scsimgr(1M). Note: The following conventions are used: o RO is Read Only. o RW is Read Write. o string is an array of characters. --------------------------------------------------------------------- Object Attribute Name RO/RW Type Description --------------------------------------------------------------------- Controller sym_port_name RW string Symbolic Port Name for fibre channel HBA con- troller Default: <host- name>_fcd<instance#> --------------------------------------------------------------------- sym_node_name RW string Symbolic Node Name for fibre channel HBA con- troller Default: <hostname>_HP- UX_<os release version> --------------------------------------------------------------------- EXAMPLES
Display all attributes for HBA controller with DSF /dev/fcd1: Get HBA controller symbolic port name for DSF /dev/fcd1: Get HBA controller symbolic node name for hardware path 0/2/1/0: Set HBA controller symbolic port name for DSF /dev/fcd1 to fcd1_port: Set HBA controller symbolic node name for class fc and instance 8 to fcd1_node: Save HBA controller symbolic port name for DSF /dev/fcd1 as fcd1_port: Save HBA controller symbolic node name for hardware path 0/2/1/0 as fcd1_node: AUTHOR
Fibre Channel interface driver plug-in for was developed by HP. SEE ALSO
scsimgr(1M), intro(7). scsimgr_fcd(7)