I have a Dell Inspiron 4000 that I am using to run Redhat Linux 7.1.
This machine had 128Mb of RAM in it, and I upgraded to 512Mb.
Since this, the PCMCIA cards have disappeared from the system running under Linux, although they still work under windows and the file "/var/lib/pcmcia/stab" only contains:
but another machine we have with the same cards shows:
If we take the memory out and use anything less than 512Mb the cards will work again, but not when 512Mb is installed, despite the fact that the BIOS and motherboard of this computer is supposed to handle this amount.
Is there any special method to allow this to work with 512Mb, without having to reinstall?
Dear:
the Cureent PC Dell GX620
the Current Hardware
4 GB ram
80 HDD
what i do
remove old 4GB ram and install 8 GB
remove old HDD and install new on 160GB
try to install the Unix Sun Solaris
after booting and when arrive to step which i should select interactive
error meg... (7 Replies)
First of all it's shut down 60 second after power on and write on console :
SC Alert: Correct SCC not replaced - shutting managed system down!
This is cured by moving out battery from ALOM card.
Now server start to loop during the testing.
That's on the console:
>@(#) Sun Fire V440,Netra... (14 Replies)
Hi there. I have an old laptop Toshiba Tecra 510 (P1, 147MB RAM, 30GB HDD) and I installed FreeBSD 7.2.
For networking I have a PCMCIA card for wired network. The problem is that I cannot start and run PCMCIA
As I know in Linux there is a tool pcmciautils for this pc-cards, but in FreeBSD I have... (1 Reply)
Hey guys how to do diagnose HP-UX for hardware problems/issues. This is a general question for all common hardware components under HP-UX server. (4 Replies)
Hey guys how to do diagnose solaris for hardware problems/issues. This is a general question for all common hardware components under solaris server. (4 Replies)
Hey guys how to do diagnose Linux for hardware problems/issues. This is a general question for all common hardware components under Linux server. (1 Reply)
Hi
I am right now facing a strange hardware problem. System get booted with the following error:
Fatal Error Reset
CPU 0000.0000.0000.0003 AFSR 0100.0000.0000.0000 SCE
AFAR 0000.07c6.0000.1000
SC Alert: Host System has Reset
It happen 4 or 5 times and get the same error every time.I... (8 Replies)
Dear All
I would Like to know that if suppose c1t0d0 is of 72 gb hard disk and system boot from this hard disk and c1t1d0 is of 147gb hard disk. Can we implement hardware raid (Mirror) between these two hard disks of different capacity if raid crontroller is present in the server
Kind regards (4 Replies)
I have worked with Qlogic (Sun) fiber cards a lot and with Emulex fiber cards only a little. Here is the scenario: I have a Sun 490 with 3 Emulex cards in it. A pair are for the 6120 array that is attached, the other is a direct attach so our SAN for Veritas Netbackup to back up the system.I... (0 Replies)
Can someone tell me what the following means? We have a v440 running Solaris 9. What do the patterns actually mean?
May 17 12:12:03 ibasdb02 cediag: Revision: 1.78 @ 2005/02/11 15:5
:29 UTC
May 17 12:12:03 ibasdb02 cediag: Analysed System: SunOS 5.9 with
UP 117171-17 (MPR active)
May 17... (5 Replies)