9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Thank you in advanced,
I had a Buffalo DUO crap out on me that was setup as RAID 0. I dont belive it was the drives but rather the controller in the DUO unit. I bought another external HDD enclosure and was able to fireup the two older DUO drives in it and I think I resembled the RAID... (12 Replies)
Discussion started by: metallica1973
12 Replies
2. Shell Programming and Scripting
trying a little bit of array scanning for open ports.
my code looks like below:
/bin/netstat -lntp|\
awk 'BEGIN { split("25 80 2020 6033 6010",q); }
$1 == "tcp" { split($4,a,":"); p]++; }
$1 == "tcp6" { split($4,a,":");p]++ }
END {
for ( i in q ) {
if (! q in p ) {... (8 Replies)
Discussion started by: busyboy
8 Replies
3. UNIX for Beginners Questions & Answers
username=cogiz
#!/bin/bash
shuffle() #@ USAGE: shuffle
{ #@ TODO: add options for multiple or partial decks
Deck=$(
printf "%s\n" {2,3,4,5,6,7,8,9,T,J,Q,K,A}{H,S,D,C} |
awk '## Seed the random number generator
BEGIN { srand() }
## Put a random number in front... (4 Replies)
Discussion started by: cogiz
4 Replies
4. UNIX for Beginners Questions & Answers
Example of problem:
computerhand=(6H 2C JC QS 9D 3H 8H 4D)
topcard=6D
How do you search ${computerhand} for all elements containing either a "6" or a "D" then
save the output to a file?
This is a part of a Terminal game of Crazy 8's that I'm attempting to write in Bash.
Any... (2 Replies)
Discussion started by: cogiz
2 Replies
5. Red Hat
Dear all ,
i ve configured raid 0 in redhat machine(VM ware), by following steps:
#mdadm -C /dev/md0 -l 0 -n 2 /dev/sdb1 /dev/sdc1
#mkfs.ext3 /dev/md0
#mdadm --detail --scan --config=mdadm.conf >/etc/mdadm.conf
then
mounted the/dev/md0 device and also added a entry in fstab.
how... (2 Replies)
Discussion started by: sriniv666
2 Replies
6. Emergency UNIX and Linux Support
One of my very old drive farm servers had an OS fault and can't boot now but I'd like to restore some files from it. I tried booting Ubuntu from a CD, but it couldn't see the drives -- possibly because they're RAIDed together. Is there a good way to get at my files?
The data in question is a... (2 Replies)
Discussion started by: CRGreathouse
2 Replies
7. Red Hat
Hi All,
I run Linux server that hosts PHP/MySQL web-projects.
The problem is that it becomes irresponsive periodically, avg. load rapidly goes up to 100.0 and more and I have to do cold reboot.
Usually this sudden increase happens in 1-2 mins and it's very difficult to catch this moment in... (0 Replies)
Discussion started by: livedatesearch
0 Replies
8. UNIX for Advanced & Expert Users
Hi guys,
i must install an old old old ml370 server...
I must create a RAID 5 with my 4 SCSI disk.
I need a SmartStart disk for create it or a Floppy Disk called "Array configuration Tool". I don't find it on the hp website...:mad::mad::mad:
Anyone have it??
Thanks in advance.
Zio (0 Replies)
Discussion started by: Zio Bill
0 Replies
9. AIX
I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
Discussion started by: scottsl
0 Replies
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)
NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)
HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD
March 3, 2008 BSD