bnx1 link : unknown


 
Thread Tools Search this Thread
Top Forums UNIX for Advanced & Expert Users bnx1 link : unknown
# 1  
Old 09-24-2009
bnx1 link : unknown

Hi,

Please could someone advise, how to enable device bnx1 to become up (online). See below for details :

dladm show-dev
e1000g0 link: up speed: 1000 Mbps duplex: full
e1000g1 link: up speed: 1000 Mbps duplex: full
e1000g2 link: up speed: 1000 Mbps duplex: full
e1000g3 link: up speed: 1000 Mbps duplex: full
e1000g4 link: up speed: 1000 Mbps duplex: full
e1000g5 link: unknown speed: 0 Mbps duplex: half
bnx0 link: unknown speed: 100 Mbps duplex: unknown
bnx1 link: unknown speed: 1000 Mbps duplex: unknown

This is system is a HP x86 solaris box, I have checked the bnx.conf file and it is set to :

0 : AutoNegotiate

see below :

speed=0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0;


regards,

Tek
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

/var/adm/messages (insterface turned off/restored) and link up & link down message.

Hi All I am facing an issue with our new solaris machine. in /var/adm/messages Apr 22 16:43:05 Prod-App1 in.routed: interface net0 to 172.16.101.1 turned off Apr 22 16:43:33 Prod-App1 mac: NOTICE: nxge0 link up, 1000 Mbps, full duplex Apr 22 16:43:34 Prod-App1 mac: NOTICE: nxge0 link... (2 Replies)
Discussion started by: javeedkaleem
2 Replies

2. Solaris

/var/adm/messages (interface turned off/restored) and link up & link down message.

Hi All I am facing an issue with our new solaris machine. in /var/adm/messages root@Prod-App1:/var/tmp# root@Prod-App1:/var/tmp# root@Prod-App1:/var/tmp# cat /var/adm//messages Apr 20 03:10:01 Prod-App1 syslogd: line 25: WARNING: loghost could not be resolved Apr 20 08:24:18 Prod-App1... (0 Replies)
Discussion started by: javeedkaleem
0 Replies

3. UNIX for Dummies Questions & Answers

[Solved] Symbolic link not allowed or link target not accessible

Hi everybody, I read about treads realted to this issue but they did not resovle issue given below. Please help me resolve issue given below I have html file under /srv/www/htdocs/actual_folder ls actual_folder/ test.html and following link works... (0 Replies)
Discussion started by: newbielgn
0 Replies

4. Programming

g++ fails to link to static library when compilation and link in single command

Hello All, I've encountered a strange behaviour from g++ that doesn't make sense to me. Maybe you can shed some light on it: I have a bunch of source files and want to compile them and link them with a static library liba.a located in /usr/local/lib64 into an executable Approach 1 works... (0 Replies)
Discussion started by: magelord
0 Replies

5. IP Networking

bnx1 link : unknown ?

Hi, Please could someone advise, how to enable device bnx1 to become up (online). See below for details : dladm show-dev e1000g0 link: up speed: 1000 Mbps duplex: full e1000g1 link: up speed: 1000 Mbps duplex: full e1000g2 link: up speed: 1000 Mbps duplex: full e1000g3 link: up speed:... (0 Replies)
Discussion started by: venhart
0 Replies

6. UNIX for Dummies Questions & Answers

Difference between hard link and soft link

Hi Experts, Please help me out to find out difference between a hard link and a soft link. I am new in unix plz help me with some example commands ( for creating such links). Regards S.Kamakshi :) (2 Replies)
Discussion started by: kamakshi s
2 Replies

7. Solaris

PING - Unknown host 127.0.0.1, Unknown host localhost - Solaris 10

Hello, I have a problem - I created a chrooted jail for one user. When I'm logged in as root, everything work fine, but when I'm logged in as a chrooted user - I have many problems: 1. When I execute the command ping, I get weird results: bash-3.00$ usr/sbin/ping localhost ... (4 Replies)
Discussion started by: Przemek
4 Replies

8. UNIX for Dummies Questions & Answers

need some info about symbolic link and hard link

hello folks how y'all doin well i have some questions about symbolic link and hard link hope some one answer me i open terminal and join as root and i wrote ln -s blah blah then i wrote ls i see red file called blah blah but didn't understand what is this can some one explain and... (2 Replies)
Discussion started by: detective linux
2 Replies

9. UNIX for Dummies Questions & Answers

Difference between hard link and soft link in unix

Hi All, Can any one please explain me what is the difference between hard link and soft link in UNIX. Thanks in advance Raja Chokalingam. (2 Replies)
Discussion started by: RAJACHOKALINGAM
2 Replies

10. UNIX for Advanced & Expert Users

Differences between hard link and soft link

Hi all! I'd like to know the differences between hard links and soft links. I've already read the ln manpage, but i'm not quite sure of what i understood. Does a hard link sort of copy the file to a new name, give it the same inode number and same rights? What exactly should I do to do this:... (3 Replies)
Discussion started by: penguin-friend
3 Replies
Login or Register to Ask a Question
dmfe(7D)							      Devices								  dmfe(7D)

NAME
dmfe - Davicom Fast Ethernet driver for Davicom DM9102A SYNOPSIS
/kernel/drv/sparcv9/dmfe DESCRIPTION
The dmfe Ethernet device provides 100Base-TX networking interfaces using the Davicom DM9102A chip, which incorporates its own internal transceiver. The dmfe driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. Multiple controllers installed within the system are supported by the driver. The 100Base-TX standard specifies an auto-negotiation protocol to automatically select the mode and speed of operation. The internal trans- ceiver is capable of performing auto-negotiation with the remote-end of the link (link partner) and receives the capabilities of the remote end. It selects the highest common denominator mode of operation based on the priorities. The internal transceiver also supports a forced- mode of operation under which the driver selects the operational mode. APPLICATION PROGRAMMING INTERFACE
The /dev/dmfe cloning character-special device is used to access all Davicom DM9102A devices installed in the system. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (ppa). The ppa ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. If the ppa field value does not correspond to a valid device instance number for this system, an error (DL_ERROR_ACK) is returned. The device is initialized on first attach and de-ini- tialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to a DL_INFO_REQ are as follows: o Maximum SDU is 1500 (ETHERMTU - defined in sys/ethernet.h). o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o The sap length value is -2, meaning the physical address component is followed immediately by a 2-byte sap component within the DLSAP address. o The broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular Service Access Point (SAP) with the stream. CONFIGURATION
By default, the dmfe driver performs auto-negotiation to select the speed and mode of the link. Link speed and mode can be 100 Mbps (full or half-duplex) or 10 Mbps (full or half-duplex) as described in the 100Base-TX standard. The auto-negotiation protocol automatically selects speed mode (either 100 Mbps or 10 Mbps) and operation mode (either full-duplex or half- duplex) as the highest common denominator supported by both link partners. Because the dmfe device supports all modes, this effectively selects the highest-throughput mode supported by the other device. Alternatively, you can explicitly specify the link parameters by adding entries to the dmfe driver configuration file (/ker- nel/drv/dmfe.conf). You can set the speed parameter to 10 or 100 to force dmfe devices to operate at the specified speed. Additionally, you can set the full-duplex parameter to 0 or 1 to disable or force full-duplex operation, respectively. Note that specifying either "speed" or "full-duplex" explicitly disables auto-negotiation. To enable the driver to determine the appropri- ate setting for each parameter, you should always set both parameters. If it is necessary to force either speed or duplex setting (for example, because the dmfe device is connected to an ancient device or hub that does not support auto-negotiation), both parameters should be explicitly specified to match the requirements of the external device. FILES
/dev/dmfe Character special device /kernel/drv/dmfe 32-bit kernel module (x86) /kernel/drv/sparcv9/dmfe 64-bit kernel module (SPARC) /kernel/drv/amd64/dmfe 64-bit kernel module (x86) /kernel/drv/dmfe.conf dmfe configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |SPARC, x86 | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5), gld(7D), dlpi(7P), streamio(7I) Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.11 17 Sep 2007 dmfe(7D)