McKesson Migrates To Linux As Boost To Patient Safety - InformationWeek

 
Thread Tools Search this Thread
Special Forums News, Links, Events and Announcements UNIX and Linux RSS News McKesson Migrates To Linux As Boost To Patient Safety - InformationWeek
# 1  
Old 12-22-2007
McKesson Migrates To Linux As Boost To Patient Safety - InformationWeek

Sat, 22 Dec 2007 11:01:12 GMT


Source...
Login or Register to Ask a Question

Previous Thread | Next Thread

2 More Discussions You Might Find Interesting

1. Solaris

boost thread not accessible to boost::move error

Hi All I am working unders Sun Solaris and I am not "/opt/boost/boost/thread/detail/thread.hpp", line 344: Error: boost::thread::thread(boost::thread&) is not accessible from boost::move(boost::detail::thread_move_t<boost::thread>). Do you know if there are other solutions other than... (2 Replies)
Discussion started by: manustone
2 Replies

2. Linux

How do I boost the Linux performace

Hi All, I installed Linux recently on my PC and finding it difficult to boost its performance. It takes hell lot of time to open Mozilla, text pad , & even the booting process is too slow, many a times I got to manually power off to shutdown the computer. I will be glad if you could help me... (18 Replies)
Discussion started by: jayfriend
18 Replies
Login or Register to Ask a Question
DCPOSN(1)						 DICOM PS3 - DICOM locate position						 DCPOSN(1)

NAME
dcposn - ACR/NEMA DICOM PS3 ... DICOM PS3 - DICOM locate position SYNOPSIS
dcposn [ -col|x n ] [ -row|y n ] [ -v|verbose ] [ -filename ] DESCRIPTION
dcposn reads the named dicom input file and locates the requested image pixel position in 3D space using the attributes of the Image Plane module (Image Position Patient and Image Orientation Patient) if present. The spatial position is described as patient (not gantry) relative x, y and z co-ordinates, where x is +ve leftwards, y is +ve anteriorly and z is +ve cranially. OPTIONS
The co-ordinates and verbose output go to standard error. The basic input switches are described in dcintro(1). Options specific to this program are: -col|x n -row|y n The specified image pixel position begins from 0 in the top left hand corner of the image. -verbose Display byte offset from file start and message start, in hexadecimal, and dump contents while reading and once read. -filename Show the name of the file supplied in the arguments; a hyphen will be reported if no filename was supplied. ENVIRONMENT
EXAMPLES
%dcposn -x 0 -y 0 expmeta.dc3 Row=0 Col=0 X=45.0 Y=-119.5 Z=119.5 FILES
SEE ALSO
dcintro(1) AUTHOR
Copyright (C) 1993-2010. David A. Clunie DBA PixelMed Publishing. All rights reserved. BUGS
This program really only exists for automated testing of the image plane module. DICOM PS3 6 March 2007 DCPOSN(1)