patchadd fails to apply a patch


 
Thread Tools Search this Thread
Operating Systems Solaris patchadd fails to apply a patch
# 8  
Old 04-10-2008
Quote:
Originally Posted by Tex-Twil
It's not really a smart way to install the Update Manager ... Smilie

tex
no, the best way is to install solaris with the SUNWxall software cluster. so you have everything you need on your system.
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

sed fails to apply substitute commands

I've made a shell script for archiving HTML pages, i.e. making them work offline plus add some features. Here is it: #!/bin/sh if || +/res/+") = "" ]; then echo "Usage: `basename $0` <4chan thread url> <>" exit 0 fi echo "4chan downloader" LOC=$(echo "$1" | sed... (23 Replies)
Discussion started by: Adolf1994
23 Replies

2. Solaris

Apply Patch 119963-21 to Solaris 10 Sparc

Hi, One of the pre requirements o upgrade Netbackup 6.5.4 to 7.1 is to apply Patch 119963-21 to all media servers. My media servers are Oracle Databases ( e-business suite and for other 3rd party app ). I read the Patch 119963-21's README and there is no Install Requirements for this... (10 Replies)
Discussion started by: HishamN
10 Replies

3. AIX

Failed to apply the IZ86736 patch in TL6 SP1

while i was trying to apply the patch IZ86736 in TL6_SP1 its give me the below error instfix -d . -p -f /tmp/.instfix_selections.20512908 > File installp -acgNqXd . -f File File: bos.rte.control 06.01.0006.0003 ... (3 Replies)
Discussion started by: thecobra151
3 Replies

4. Solaris

patchadd command

# patchadd /Desktop/117837-08.jar Validating patches... Loading patches installed on the system... Done! Loading patches requested to install. Done! The following requested patches have packages not installed on the system Package SPROcc from directory SPROcc in patch 117837-08 is... (19 Replies)
Discussion started by: seyiisq
19 Replies

5. Solaris

patchadd error

Greetings All- I ran into this problem today and was curious if anyone else had seen it. I am attempting to add patch 137402-02 on a v890 running Sol9. Here's the error I get: #> patchadd 137402-02 Checking installed patches... Verifying sufficient filesystem capacity (dry run... (7 Replies)
Discussion started by: bluescreen
7 Replies

6. Solaris

Patchadd error

Hi, I have a Sun fire V280R server and when i updated the kernel patch i got this error. mdb not found: patchadd not safe. /kernel/dacf/sparcv9/usb_ac_dacf: undefined symbol 'am_attach' /kernel/dacf/sparcv9/usb_ac_dacf: undefined symbol 'am_src2' /kernel/dacf/sparcv9/usb_ac_dacf: undefined... (3 Replies)
Discussion started by: Jartan
3 Replies

7. Programming

Apply patch for make file.

I just downloaded a updating make file to build Ethereal to .dll file, but I don't know how to update the old make file with this new one. Please help.. thnx a lot. (1 Reply)
Discussion started by: blueblood
1 Replies

8. Solaris

patchadd/patchrm

Ok, I attempted to apply a patch to a V440 and it bailed part way through. When I tried to patchrm the patch (after booting from CD), patchrm said that I had to fully install the failed patch before I could delete it. Since installing it killed the system forcing a boot from CD, it sounds like a... (4 Replies)
Discussion started by: BOFH
4 Replies

9. IP Networking

Patch-o-matic (patch for iptable) for linux2.4.08 & iptable1.2.7a

Hello friends I'm running Redhat 9.0 with linux kernel 2.4.20-8 & have iptables version 1.2.7a & encountering a problem that I narrate down. I need to apply patch to my iptable and netfilter for connection tracking and load balancing that are available in patch-o-matic distribution by netfilter.... (0 Replies)
Discussion started by: Rakesh Ranjan
0 Replies
Login or Register to Ask a Question
pprosvc(1M)						  System Administration Commands					       pprosvc(1M)

NAME
pprosvc - automation service program for Patch Manager SYNOPSIS
/usr/sbin/pprosvc [-c config-name] [-d [-p patch-id [,patch-id...]]] [-h] [-i [-n] [-p patch-id [,patch-id...]]] [-l] DESCRIPTION
Note - This command is deprecated. Use the smpatch analyze, smpatch download, and smpatch update commands instead. See the smpatch(1M) man page. Use the pprosvc command to analyze a system to determine the list of appropriate patches, download the patches, and apply them. This com- mand invokes patch operations in response to a user request or at a scheduled time. You must run this command as superuser. The pprosvc command enables you to do the following: o Analyze the host system for appropriate patches based on an established configuration o Generate the list of appropriate patches o Download the patches to your host system from the Sun patch server o Apply the patches based on a patch policy Use the pprosvc -i command to analyze a system, download the appropriate patches, and apply them. If analysis determines that patches are needed, the pprosvc command downloads them and applies them. Specify other options to automate a subset of the patch management tasks. If you specify the -d option, your system is analyzed and the appropriate patches are downloaded to your system. If you specify the -l option, your system is analyzed and the appropriate patches are listed. The list of patches that is generated by the analysis is based on all of the available patches from the Sun patch server. No explicit information about your host system or its network configuration is transmitted to Sun. Only a request for the Sun patch set is transmitted. The patch set is scanned for patches that are appropriate for this host system, the results are displayed, and those patches are optionally downloaded. The -d, -i, and -l options are mutually exclusive. Use the -p option to specify the patches on which to operate. You can use the -p option with the -d and -i options. OPTIONS
The following options are supported: -c config-name Uses an alternate configuration for the current patch operation. Use the pprosetup command to create new configura- tions. A configuration named recommended is included. For more information, see ``Specifying Alternate Configurations'' in the pprosetup(1M) man page. Note - This feature is not supported by the smpatch command. -d Downloads the patches that are appropriate for this host system. The patches are downloaded to the designated down- load directory. This option generates a list of appropriate patches, as does the -l option. However, instead of just displaying the list of patches, the -d option displays and downloads the patches from the Sun patch server. The patches are down- loaded using a secure connection, and all patches are authenticated using digital signature technology. Only patches that are signed with a Sun digital signature are stored in your download directory. Note - Specifying this option is equivalent to running the smpatch download command. -h Displays information about the command-line options. -i Applies the patches based on the patch policy. This option analyzes your system to generate a list of appropriate patches. If analysis determines that patches are needed, the patches are downloaded and applied. If no patches are permitted to be applied in automatic mode (by running pprosetup -p none), this option is identical to specifying the -d option. If only standard patches are permitted to be applied in automatic mode (by running pprosetup -p standard), all standard patches are applied. Note - Specifying this option is equivalent to running the smpatch update command. -l Generates a list of the patches that are appropriate for this host system. Note - Specifying this option is equivalent to running the smpatch analyze command. -n Runs pprosvc in automatic mode. The command that the cron job specifies is pprosvc -i -n. To schedule patch opera- tions to run in automatic mode, see the pprosetup(1M) man page. In automatic mode, the patch administrator (specified by the -a option) receives email notifications that describe the patches you downloaded and applied, and any error events that occurred. Do not use this option on the command line. Standard patches do not require any special actions on the part of the user. Such patches can be applied by using the patchadd command (see the patchadd(1M) man page) and do not need the host system to reboot for the patch to take effect. All nonstandard patches are moved to the sequester directory if you use the -n option to run in automatic mode. If you run in manual mode, however, nonstandard patches that have properties that match the policy specified by ppros- etup -i are applied. The rest of the nonstandard patches are moved to the sequester directory. You can apply patches from this directory at a later time. Patches, whether standard or nonstandard, that depend on sequestered patches are not applied under any circumstances. Such patches are placed in the sequester directory. For any patch that is placed in the sequester directory, refer to the patch's README file to determine how to apply it to your system. Note - This feature is not supported by the smpatch command. -p [patch-id[,patch-id,.Designates the specific patches on which to operate. Use this option with the -d option or the -i option. The list of patch IDs must be separated by commas. The specified patches are adjusted to use the current versions based on the patch baseline. Patches that are required by the specified patches are added to the complete list of patches to be applied. Note - Specifying this option is equivalent to specifying the -i option to the smpatch analyze, smpatch download, and smpatch update commands. EXAMPLES
Example 1: Applying Specific Patches in Manual Mode # pprosvc -i -p 102893-01,106895-09,106527-05 Applies patches 102893-01, 106895-09, and 106527-05 to the local system in manual mode. Example 2: Analyzing a System and Downloading Appropriate Patches # pprosvc -i Performs an analysis of the current system and downloads the appropriate patches based on all the patches from the Sun patch server. The resulting list of patches can be very long. Example 3: Applying Patches From the Recommended Configuration # pprosvc -c recommended -i Uses the recommended configuration to perform an analysis of the current system and downloads the appropriate patches. Standard patches and those needed from the recommended configuration are applied to the system based on the established patch policy. For information about set- ting the patch policy for manual mode, see the description of the -i option on the pprosetup(1M) man page. ATTRIBUTES
See the attributes(5) man page for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpprou | +-----------------------------+-----------------------------+ |Interface Stability |Obsolete | +-----------------------------+-----------------------------+ SEE ALSO
patchadd(1M), patchrm(1M), pprosetup(1M), smc(1M), smpatch(1M), attributes(5) SunOS 5.10 7 May 2004 pprosvc(1M)