9 More Discussions You Might Find Interesting
1. Solaris
Hi,
I'm looking to copy a boot disk on an old Solaris 8 system using dd. I'll bring the system down to single user mode and begin from there. I'm copying my source disk to a larger target disk. Do I need to do anything other than the 'dd' command below because the target disk is bigger? ... (2 Replies)
Discussion started by: sparcman
2 Replies
2. Solaris
Hi
The scenario in the oracle t4-1 hardware with solaris 10 is as follows:
1. The initial install on the server was performed with an incorrect disk layout.
2. New disks were ordered and slot into the server.
3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies
3. Solaris
I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all.
How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies
4. SCO
So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller.
First, I downloaded the megasas driver from SCO and installed it on the old system.
Then I created a new Microlite Edge emergency boot cd with the new driver on it.
I... (2 Replies)
Discussion started by: jgt
2 Replies
5. Solaris
hi all
i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output
# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies
6. SCO
I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd.
I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies
7. HP-UX
Replace an unknown status controller on HP FC60 disk array
Author:JoyOnline JoyChangLu@gmail.com
Trouble description:
The users detected that the status of controller at A is unknown.
Analysis and diagnostic:
Physical observed all leds on enclosure of disk array is normal.
The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies
8. SCO
hi...
i hav a problem to install sco unix
while installing sco unix 5.0.5 in acer altos with hardware raid
am getting error
"Warning HD: no root disk controller was found
system error 5: while getting fs type
flushing controller: DAC960PRL cache done."
i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies
9. UNIX for Dummies Questions & Answers
Hi there!
I received the following error message
The hard disk at channel 2, target 1 had a soft error.
The output of a system check reveiled the following (see entry <2,1> ):
SWXCR xcr0 error counters:
RAID Array 200 Controller Family Information Utility V1.03... (1 Reply)
Discussion started by: Ivo
1 Replies