Code:
Nov 17 21:48:32 test.alshaya.com scsi: [ID 107833 kern.notice] Requested Block: 155320 Error Block: 155320
Nov 17 21:48:32 test.alshaya.com scsi: [ID 107833 kern.notice] Vendor: DGC Serial Number: 0D54F58DFBCL
Nov 17 21:48:32 test.alshaya.com scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Nov 17 21:48:32 test.alshaya.com scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
Nov 17 21:49:33 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:49:33 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:49:33 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 17 21:49:33 test.alshaya.com SCSI transport failed: reason 'timeout': retrying command
Nov 17 21:50:33 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:50:33 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:51:34 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:51:34 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:51:44 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:51:44 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:53:36 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:53:36 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:54:37 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:54:37 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:55:38 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:55:38 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:56:38 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:56:38 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:57:39 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:57:39 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:58:40 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:58:40 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:58:43 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 17 21:58:43 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 17 21:58:43 test.alshaya.com SCSI transport failed: reason 'tran_err': retrying command
Nov 17 21:58:43 test.alshaya.com genunix: [ID 153160 kern.warning] WARNING: Page83 data not standards compliant DGC LUNZ 0533
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 17 21:58:43 test.alshaya.com Error for Command: write(10) Error Level: Retryable
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.notice] Requested Block: 160558 Error Block: 160558
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.notice] Vendor: DGC Serial Number: 0D54F58DFBCL
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Nov 17 21:58:43 test.alshaya.com scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
Nov 17 21:59:44 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 21:59:44 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 21:59:44 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 17 21:59:44 test.alshaya.com SCSI transport failed: reason 'timeout': retrying command
Nov 17 22:00:45 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:00:45 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:01:46 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:01:46 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:02:47 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:02:47 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:02:57 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:02:57 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:04:49 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:04:49 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:05:49 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:05:49 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:06:50 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:06:50 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:07:51 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:07:51 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:08:01 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:08:01 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:08:52 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:08:52 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:09:53 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:09:53 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:10:53 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:10:53 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:11:54 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:11:54 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:12:55 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:12:55 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:13:56 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:13:56 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:14:06 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:14:06 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:15:58 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:15:58 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:16:08 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:16:08 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:18:00 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:18:00 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:19:10 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 17 22:19:10 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 17 22:42:05 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 17 22:42:05 test.alshaya.com last message repeated 1 time
Nov 18 00:42:11 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 00:42:11 test.alshaya.com last message repeated 1 time
Nov 18 02:42:16 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 02:42:16 test.alshaya.com last message repeated 1 time
Nov 18 04:42:21 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 04:42:21 test.alshaya.com last message repeated 1 time
Nov 18 06:42:25 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 06:42:25 test.alshaya.com last message repeated 1 time
Nov 18 08:42:30 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 08:42:30 test.alshaya.com last message repeated 1 time
Nov 18 10:42:35 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 10:42:35 test.alshaya.com last message repeated 1 time
Nov 18 12:42:41 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
Nov 18 13:15:17 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:15:17 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:16:18 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 18 13:16:18 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 18 13:19:27 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:19:27 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:19:28 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:19:28 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:19:29 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:19:29 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:20:30 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 18 13:20:30 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 18 13:25:20 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:25:20 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:25:20 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 18 13:25:20 test.alshaya.com SCSI transport failed: reason 'tran_err': retrying command
Nov 18 13:26:30 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):
Nov 18 13:26:30 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command Timeout on path fp5/ssd@w5006016808603b42,1
Nov 18 13:26:30 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 18 13:26:30 test.alshaya.com SCSI transport failed: reason 'timeout': retrying command
Nov 18 13:34:34 test.alshaya.com scsi: [ID 243001 kern.info] /scsi_vhci (scsi_vhci0):
Nov 18 13:34:34 test.alshaya.com /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10): Command failed to complete (3) on path fp5/ssd@w5006016808603b42,1
Nov 18 13:34:34 test.alshaya.com scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10):
Nov 18 13:34:34 test.alshaya.com SCSI transport failed: reason 'tran_err': retrying command
Nov 18 13:36:19 test.alshaya.com fp: [ID 517869 kern.info] NOTICE: fp(5): PLOGI to 20000 failed state=Timeout, reason=Hardware Error
Nov 18 13:36:19 test.alshaya.com fctl: [ID 517869 kern.warning] WARNING: fp(5)::PLOGI to 20000 failed. state=c reason=1.
Nov 18 13:36:19 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:19 test.alshaya.com PLOGI to D_ID=0x20000 failed: State:Timeout, Reason:Hardware Error. Giving up
Nov 18 13:36:39 test.alshaya.com scsi: [ID 243001 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:39 test.alshaya.com offlining lun=1 (trace=0), target=20000 (trace=2800101)
Nov 18 13:36:39 test.alshaya.com scsi: [ID 243001 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:39 test.alshaya.com offlining lun=0 (trace=0), target=20000 (trace=2800101)
Nov 18 13:36:39 test.alshaya.com genunix: [ID 483743 kern.info] /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10) multipath status: optimal: path 5 fp5/ssd@w5006016808603b42,1 is offline
Nov 18 13:36:39 test.alshaya.com genunix: [ID 408114 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0/ssd@w5006016808603b42,0 (ssd6) offline
Nov 18 13:42:43 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.
bash-3.2# tail -f /var/adm/messages
Nov 18 13:36:19 test.alshaya.com fctl: [ID 517869 kern.warning] WARNING: fp(5)::PLOGI to 20000 failed. state=c reason=1.
Nov 18 13:36:19 test.alshaya.com scsi: [ID 243001 kern.warning] WARNING: /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:19 test.alshaya.com PLOGI to D_ID=0x20000 failed: State:Timeout, Reason:Hardware Error. Giving up
Nov 18 13:36:39 test.alshaya.com scsi: [ID 243001 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:39 test.alshaya.com offlining lun=1 (trace=0), target=20000 (trace=2800101)
Nov 18 13:36:39 test.alshaya.com scsi: [ID 243001 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0 (fcp5):
Nov 18 13:36:39 test.alshaya.com offlining lun=0 (trace=0), target=20000 (trace=2800101)
Nov 18 13:36:39 test.alshaya.com genunix: [ID 483743 kern.info] /scsi_vhci/ssd@g6006016053c038008b0b1abc90c1e411 (ssd10) multipath status: optimal: path 5 fp5/ssd@w5006016808603b42,1 is offline
Nov 18 13:36:39 test.alshaya.com genunix: [ID 408114 kern.info] /pci@7c0/pci@0/pci@9/SUNW,qlc@0,1/fp@0,0/ssd@w5006016808603b42,0 (ssd6) offline
Nov 18 13:42:43 test.alshaya.com SC Alert: [ID 628137 daemon.alert] BATTERY at SC/BAT/V_BAT has exceeded low warning threshold.