Code:
root@external-speedtest -> grep net /etc/path_to_inst
"/pci@1f,700000/network@2" 0 "bge"
"/pci@1f,700000/network@2,1" 1 "bge"
"/pci@1d,700000/network@2" 2 "bge"
"/pci@1d,700000/network@2,1" 3 "bge"
root@external-speedtest -> prtdiag -v
System Configuration: Sun Microsystems sun4u Netra 240
System clock frequency: 160 MHZ
Memory size: 2GB
==================================== CPUs ====================================
E$ CPU CPU Temperature Fan
CPU Freq Size Impl. Mask Die Ambient Speed Unit
--- -------- ---------- ------ ---- -------- -------- ----- ----
MB/P0 1280 MHz 1MB US-IIIi 2.4 - -
MB/P1 1280 MHz 1MB US-IIIi 2.4 - -
================================= IO Devices =================================
Bus Freq
Brd Type MHz Slot Name Model
--- ---- ---- ---------- ---------------------------- --------------------
0 pci 66 MB pci108e,1648 (network)
0 pci 66 MB pci108e,1648 (network)
0 pci 33 MB isa/su (serial)
0 pci 33 MB isa/su (serial)
0 pci 33 MB pci10b9,5229 (ide)
0 pci 66 MB scsi-pci1000,21 (scsi-2)
0 pci 66 MB scsi-pci1000,21 (scsi-2)
0 pci 66 MB pci108e,1648 (network)
0 pci 66 MB pci108e,1648 (network)
0 pci 33 7 isa/rmc-comm-rmc_comm (seria+
============================ Memory Configuration ============================
Segment Table:
-----------------------------------------------------------------------
Base Address Size Interleave Factor Contains
-----------------------------------------------------------------------
0x0 2GB 2 BankIDs 0,1
Bank Table:
-----------------------------------------------------------
Physical Location
ID ControllerID GroupID Size Interleave Way
-----------------------------------------------------------
0 0 0 1GB 0,1
1 0 0 1GB
Memory Module Groups:
--------------------------------------------------
ControllerID GroupID Labels
--------------------------------------------------
0 0 MB/P0/B0/D0,MB/P0/B0/D1
============================ Environmental Status ============================
Fan Speeds:
-----------------------------------------
Location Sensor Status Speed
-----------------------------------------
MB/P0/F0 RS okay 4245 rpm
MB/P0/F1 RS okay 4115 rpm
F2 RS okay 4470 rpm
PS0 FF_FAN okay
PS1 FF_FAN okay
---------------------------------
Keyswitch:
---------------------------------
Location Keyswitch State
---------------------------------
--------------------------------------------------
Led State:
--------------------------------------------------
Location Led State Color
--------------------------------------------------
MB ACT on green
MB SERVICE off amber
MB LOCATE off white
PS0 ACT on green
PS0 SERVICE off amber
PS0 OK2RM off blue
PS1 ACT on green
PS1 SERVICE off amber
PS1 OK2RM off blue
HDD0 SERVICE off amber
HDD0 OK2RM off blue
HDD1 SERVICE off amber
HDD1 OK2RM off blue
-------------------------------------------------------------------
Temperature sensors:
-------------------------------------------------------------------
Location Sensor Temperature Lo LoWarn HiWarn Hi Status
-------------------------------------------------------------------
MB T_ENC 27C -9C -7C 57C 60C okay
MB/P0 T_CORE 76C - - 110C 115C okay
MB/P1 T_CORE 58C - - 110C 115C okay
PS0 FF_OT - - - - - okay
PS1 FF_OT - - - - - okay
------------------------------------------------------------------------
Voltage sensors:
------------------------------------------------------------------------
Location Sensor Voltage Lo LoWarn HiWarn Hi Status
------------------------------------------------------------------------
MB V_VTT 1.31V - 1.17V 1.43V - okay
MB V_GBE_+2V5 2.51V - 2.25V 2.75V - okay
MB V_GBE_CORE 1.21V - 1.08V 1.32V - okay
MB V_VCCTM 2.54V - 2.25V 2.75V - okay
MB V_+2V5 2.61V - 2.34V 2.86V - okay
MB V_+1V5 1.51V - 1.35V 1.65V - okay
MB/BAT V_BAT 3.03V - 2.70V - - okay
MB/P0 V_CORE 1.48V - 1.26V 1.54V - okay
MB/P1 V_CORE 1.48V - 1.26V 1.54V - okay
PS0 FF_UV - - - - - okay
PS0 FF_OV - - - - - okay
PS0 P_PWR - - - - - okay
PS1 FF_UV - - - - - okay
PS1 FF_OV - - - - - okay
PS1 P_PWR - - - - - okay
----------------------------------------------------------------------
Current sensors:
----------------------------------------------------------------------
Location Sensor Current Lo LoWarn HiWarn Hi Status
----------------------------------------------------------------------
MB FF_SCSI - - - - - okay
PS0 FF_OC - - - - - okay
PS1 FF_OC - - - - - okay
======== FRU Status =========
-------------------------
Fru Operational Status:
-------------------------
Location Status
-------------------------
MB/SC okay
PS0 okay
HDD0 present
HDD1 present
PS1 okay
================================ HW Revisions ================================
ASIC Revisions:
---------------
pci: Rev 4
pci: Rev 4
pci: Rev 4
pci: Rev 4
System PROM revisions:
----------------------
OBP 4.22.23 2006/11/27 04:43 Sun Fire V210/V240,Netra 210/240
OBDIAG 4.22.23 2006/11/27 05:01
root@external-speedtest -> prtpicl -c network -v
network (network, 2f60000015f)
:_fru_parent (2f60000072bH)
:DeviceID 0x2
:UnitAddress 2
:vendor-id 0x14e4
:device-id 0x1648
:revision-id 0
:subsystem-vendor-id 0x108e
:subsystem-id 0x1648
:class-code 0x20000
:interrupts 00 00 00 01
:min-grant 0x40
:max-latency 0
:cache-line-size 0x10
:latency-timer 0x40
:devsel-speed 0x1
:fast-back-to-back
:66mhz-capable
:device_type network
:address-bits 0x30
:max-frame-size 0x10000
:reg
00 00 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
03 00 10 10 00 00 00 00 00 00 00 00 00 00 00 00 00 20 00 00
03 00 10 18 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00
:compatible (2f60000016aTBL)
| pci14e4,1648.108e.1648.0 |
| pci14e4,1648.108e.1648 |
| pci108e,1648 |
| pci14e4,1648.0 |
| pci14e4,1648 |
| pciclass,020000 |
| pciclass,0200 |
:assigned-addresses
83 00 10 10 00 00 00 00 00 20 00 00 00 00 00 00 00 20 00 00
83 00 10 18 00 00 00 00 00 11 00 00 00 00 00 00 00 01 00 00
:local-mac-address 00 03 ba bc 0f 05
:devfs-path /pci@1f,700000/network@2
:driver-name bge
:binding-name pci108e,1648
:bus-addr 2
:instance 0
:_class network
:name network
network (network, 2f600000184)
:_fru_parent (2f60000072bH)
:DeviceID 0x2
:UnitAddress 2,1
:vendor-id 0x14e4
:device-id 0x1648
:revision-id 0
:subsystem-vendor-id 0x108e
:subsystem-id 0x1648
:class-code 0x20000
:interrupts 00 00 00 02
:min-grant 0x40
:max-latency 0
:cache-line-size 0x10
:latency-timer 0x40
:devsel-speed 0x1
:fast-back-to-back
:66mhz-capable
:device_type network
:address-bits 0x30
:max-frame-size 0x10000
:reg
00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
03 00 11 10 00 00 00 00 00 00 00 00 00 00 00 00 00 20 00 00
03 00 11 18 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00
:compatible (2f60000018fTBL)
| pci14e4,1648.108e.1648.0 |
| pci14e4,1648.108e.1648 |
| pci108e,1648 |
| pci14e4,1648.0 |
| pci14e4,1648 |
| pciclass,020000 |
| pciclass,0200 |
:assigned-addresses
83 00 11 10 00 00 00 00 00 40 00 00 00 00 00 00 00 20 00 00
83 00 11 18 00 00 00 00 00 12 00 00 00 00 00 00 00 01 00 00
:local-mac-address 00 03 ba bc 0f 06
:devfs-path /pci@1f,700000/network@2,1
:driver-name bge
:binding-name pci108e,1648
:bus-addr 2,1
:instance 1
:_class network
:name network
network (network, 2f600000442)
:_fru_parent (2f60000072bH)
:DeviceID 0x2
:UnitAddress 2
:vendor-id 0x14e4
:device-id 0x1648
:revision-id 0
:subsystem-vendor-id 0x108e
:subsystem-id 0x1648
:class-code 0x20000
:interrupts 00 00 00 01
:min-grant 0x40
:max-latency 0
:cache-line-size 0x10
:latency-timer 0x40
:devsel-speed 0x1
:fast-back-to-back
:66mhz-capable
:device_type network
:address-bits 0x30
:max-frame-size 0x10000
:reg
00 00 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
03 00 10 10 00 00 00 00 00 00 00 00 00 00 00 00 00 20 00 00
03 00 10 18 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00
:compatible (2f60000044dTBL)
| pci14e4,1648.108e.1648.0 |
| pci14e4,1648.108e.1648 |
| pci108e,1648 |
| pci14e4,1648.0 |
| pci14e4,1648 |
| pciclass,020000 |
| pciclass,0200 |
:assigned-addresses
83 00 10 10 00 00 00 00 00 20 00 00 00 00 00 00 00 20 00 00
83 00 10 18 00 00 00 00 00 11 00 00 00 00 00 00 00 01 00 00
:local-mac-address 00 03 ba bc 0f 07
:devfs-path /pci@1d,700000/network@2
:driver-name bge
:binding-name pci108e,1648
:bus-addr 2
:instance 2
:_class network
:name network
network (network, 2f600000467)
:_fru_parent (2f60000072bH)
:DeviceID 0x2
:UnitAddress 2,1
:vendor-id 0x14e4
:device-id 0x1648
:revision-id 0
:subsystem-vendor-id 0x108e
:subsystem-id 0x1648
:class-code 0x20000
:interrupts 00 00 00 02
:min-grant 0x40
:max-latency 0
:cache-line-size 0x10
:latency-timer 0x40
:devsel-speed 0x1
:fast-back-to-back
:66mhz-capable
:device_type network
:address-bits 0x30
:max-frame-size 0x10000
:reg
00 00 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
03 00 11 10 00 00 00 00 00 00 00 00 00 00 00 00 00 20 00 00
03 00 11 18 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00
:compatible (2f600000472TBL)
| pci14e4,1648.108e.1648.0 |
| pci14e4,1648.108e.1648 |
| pci108e,1648 |
| pci14e4,1648.0 |
| pci14e4,1648 |
| pciclass,020000 |
| pciclass,0200 |
:assigned-addresses
83 00 11 10 00 00 00 00 00 40 00 00 00 00 00 00 00 20 00 00
83 00 11 18 00 00 00 00 00 12 00 00 00 00 00 00 00 01 00 00
:local-mac-address 00 03 ba bc 0f 08
:devfs-path /pci@1d,700000/network@2,1
:driver-name bge
:binding-name pci108e,1648
:bus-addr 2,1
:instance 3
:_class network
:name network