9 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
Hi Guys,
I am stuck in between and seeking help here.
Requirement: A script that will run every morning which will connect to Mysql database and run the query to inform us about the holidays (it will also check if there were any holidays during last 2 business days). So the three queries are... (11 Replies)
Discussion started by: Sambit Sahu
11 Replies
2. Solaris
Hi,
I am facing issue with one of the drive is solaris 10. it is showing offline in the messages file
scsi: WARNING: /pci@2,600000/QLGC,qlc@0/fp@0,0/ssd@w5006016746e00b1b,0 (ssd0):
drive offline
genunix: WARNING: Page83 data not standards compliant DGC LUNZ 0430
... (1 Reply)
Discussion started by: Prasanth T K
1 Replies
3. HP-UX
Hi,
I wanted to configure new iscsi port on HPUX system, i added the target port address and configured it, once done, went to array side and searched for that host iqn number , but was nt able to find the same, came to host, then when i ran "iscsiutil -pVS" command it gave me below result
... (0 Replies)
Discussion started by: Vinay Kumar D
0 Replies
4. Solaris
Hi,
I've noticed that mpathadm states that one of our luns has no active paths:
/dev/rdsk/c6t60000970000298700009533031324333d0s2
Total Path Count: 4
Operational Path Count: 4
/dev/rdsk/c6t60000970000298700009533031333037d0s2
... (3 Replies)
Discussion started by: badoshi
3 Replies
5. UNIX for Dummies Questions & Answers
Greetings!
I need a quick way to change the format in a table of data
Here is an example of the input:
10 72 Value=177 VDB=0.0245 Value4=0,0,171,0
10 274 Value=238 VDB=0.0433 Value4=29,0,205,0
10 312 Value=222 VDB=0.0384 Value4=8,0,190,19
10 540 Value=405 VDB=0.0391 Value4=13,30,153,195... (3 Replies)
Discussion started by: Twinklefingers
3 Replies
6. Red Hat
Hi guys I have been asked for the following:
SMI Oracle database PTP10 Oracle 10g RAC on usdfslprac4 and usdfslprac5 Linux boxes is reaching its space limit. It is just 20 GB away from being completely out of disk space. And then database will stop working and SMI system hence will be impacted.... (0 Replies)
Discussion started by: 300zxmuro
0 Replies
7. Solaris
Hi Kudo,
I wanna to know that how can I do mpxio device name to os native name mapping without using stmsboot -L I tried everything still not able to got the solution till I able to get these o/p
here is native disk info as well physical wat is the logical OS name of the disk
... (1 Reply)
Discussion started by: tarunn.dubeyy
1 Replies
8. Filesystems, Disks and Memory
hi fren
i am facing this problem
i have sun 6140 storage
30 volumes
bt my vxdisk list output is showing 37 disk
which shd nt b there
has neone faced this proble earlier
vxdiks list output is like this
SUN6140-2_0 auto - - online c4t201700A0B84853C0d2s2
SUN6140-2_1 auto - - online... (13 Replies)
Discussion started by: bond_ankur
13 Replies
9. Shell Programming and Scripting
Hello,
For 2 days now i've been searching for a solution to this. I am now beginning to doubt this is even possible. It's even harder when you don't know how to search for it. (which keywords generate enough relevancy etc..)
I need to parse a config file to generate a CSV file in return.
It... (7 Replies)
Discussion started by: zer0dvide
7 Replies
format(1M) format(1M)
NAME
format - format an HP SCSI disk array LUN
SYNOPSIS
device_file
DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format,
in which the controller writes zeroes to the data area and parity area, if any, of the LUN.
NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a
regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol-
lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows:
1. The controller received a Mode Select command which requires a drive sector size change.
2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03).
3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives
will be formatted.
4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set.
RETURN VALUE
returns the following values:
0 Successful completion.
-1 Command failed.
DIAGNOSTICS AND ERRORS
Errors can originate from problems with:
o
o SCSI (device level) communications
o system calls
Error messages generated by format:
An error in command syntax has occurred.
Enter command again with all required arguments, in the order shown.
To ensure that
does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the
disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by
the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to
deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)).
The LUN number, which is derived from the device file name, is out of range.
The addressed LUN
is not configured, and thus is not known to the array controller.
Utilities must be able to open the device file for raw access.
The device being addressed is not an HP SCSI disk array.
SCSI (device level) communication errors:
Sense data associated with the failed operation is printed.
Error messages generated by system calls:
uses the following system calls:
and
Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not
alter the value of The interpretation of for printing purposes is performed by the system utility
EXAMPLES
To format the HP SCSI disk array LUN on a Series 800:
WARNING
The command will destroy all user data on the addressed LUN.
DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X.
The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X.
AUTHOR
was developed by HP.
format(1M)