7 More Discussions You Might Find Interesting
1. SCO
I was asked to get a Dell PowerEdge 2600 server, out of warranty, running SCO 3.2v5.06 to perform a full backup. I spent hours researching and preparing a strategy only to fail on-site.
The only device names in /dev for a tape drive were
/dev/xStp0
/dev/xcdt0
/dev/xct0
... (6 Replies)
Discussion started by: ezlarry
6 Replies
2. Programming
Hi,
I have a C++ program to access /dev/mem and retrieve details like Vendor, Manufacturer details of the motherboard. This works fine on all the machines except for on Dell Poweredge 2850,1950... machines.
I receive a 'EFAULT' when I try to access /dev/mem on these servers.
I suspect some... (1 Reply)
Discussion started by: ragisreekanth
1 Replies
3. UNIX for Dummies Questions & Answers
I have 2 Dell Poweredge 1950 servers running . I have been having intermittent performance issues with the NIC cards on one of them. The two servers are identical and are running the same operating system. The server that has the issue is on the DMZ on a a static IP and is hosting a website. ... (0 Replies)
Discussion started by: skotapal
0 Replies
4. Filesystems, Disks and Memory
Does anybody no how to get around the fact that the Red Hat installation does not see the SCSI hard drives. It lets you manually pick the proper device, but still fails saying no drive detected (or something to that effect). I was going to install windows 2003 Server and use VMware...but again,... (1 Reply)
Discussion started by: Fatflea
1 Replies
5. Solaris
hi, i am trying to install solaris 10 (on 4 cd's downloaded from the sun website) on my dell poweredge 2800 server. 2 xeon processors, 2GB of RAM and 2 NICS, 73 GB SCSI (maxtor ultra320, 3.5 series), i can give more details on request...
the installation crashes when trying to detect the NICS... (0 Replies)
Discussion started by: xinugeek
0 Replies
6. Linux Benchmarks
CPU/Speed: Dual PIII 533
Ram: 256Mb PC133
Motherboard: Unknown, Intel Chipset
Cache: 256k on board
Controller: PARC Raid 2/Si, AIC-7880U
Disk: 30Gb RAID 5
Load: 1 user. Clean boot, init 5 but X-Windows not loaded.
Kernel: See Benchmarks.
pgms: gcc 3.2.3
... (2 Replies)
Discussion started by: Garp
2 Replies
7. Linux Benchmarks
Notes:
System Configuration: Dell Computer Corporation PowerEdge 4600 (4 X Intel(R) XEON(TM) CPU 2.00GHz
1988.782 MHz) hyperthreaded
System clock frequency: 99.0827 MHz
Memory size (approximate): 2559 Megabytes
========================= CPUs ========================
CPU # CPU... (0 Replies)
Discussion started by: tnorth
0 Replies
AAC(4) BSD Kernel Interfaces Manual AAC(4)
NAME
aac -- Adaptec AdvancedRAID Controller driver
SYNOPSIS
aac* at pci? dev ? function ?
ld* at aac? unit ?
DESCRIPTION
The aac driver provides support for the Adaptec AAC family of SCSI and SATA RAID controllers. These controllers support RAID 0, 1, 5, 10,
and volume sets. They have four channels in the add-in version or 1-2 channels in the motherboard integrated version, and are most often
found rebadged by Dell, Hewlett-Packard or IBM. Supported controllers include:
o Adaptec AAC-364
o Adaptec SCSI RAID 2120S
o Adaptec SCSI RAID 2200S
o Adaptec SATA RAID 2410SA
o Adaptec SATA RAID 3405
o Adaptec SCSI RAID 5400S
o Dell PERC 2/Si
o Dell PERC 2/QC
o Dell PERC 3/Di
o Dell PERC 3/Si
o Dell PERC 320/DC
o Dell CERC SATA RAID 1.5/6ch
o HP NetRAID 4M
o HP ML110 G2 (Adaptec SATA RAID 2610SA)
o IBM ServeRAID 8k
Access to RAID containers is available via the ld device driver. Individual drives cannot be accessed unless they are part of a container or
volume set, and non-fixed disks cannot be accessed. Containers can be configured by using the on-board BIOS utility of the card.
DIAGNOSTICS
The adapter can send status and alert messages asynchronously to the driver. These messages are printed on the system console.
SEE ALSO
intro(4), ld(4)
HISTORY
The aac driver first appeared in NetBSD 1.6, and was based on the FreeBSD driver of the same name.
BUGS
This driver is not compatible with controllers that have version 1.x firmware. The firmware version is the same as the kernel version
printed in the BIOS POST and driver attach messages.
BSD
February 19, 2011 BSD