ILOM 'set: unable to configure network' error


 
Thread Tools Search this Thread
Operating Systems Solaris Solaris BigAdmin RSS ILOM 'set: unable to configure network' error
# 1  
Old 03-09-2009
ILOM 'set: unable to configure network' error

Thread discussing what to do when you get the error "set: unable to configure network." when using Integrated Lights Out Manager (ILOM).

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Red Hat

Unable to configure Photon3G in RHEL6.5

Hi All, Has Any body configured Photon3G ( ZTE MF190 ) on RHEL6.5. Any Device as below .. Bus 001 Device 033: ID 19d2:1254 ZTE WCDMA Technologies MSM Kernel -- 2.6.32-431.30.1.el6.x86_64 Usb modeswitch Version .. usb_modeswitch-data-20120815-2.el6.noarch... (0 Replies)
Discussion started by: linux.amrit
0 Replies

2. Linux

Unable to configure in VMWARE

Hi All, I installed Red-hat linux(64bit-x86) os on vmware 8,configure IP address and services but it is unable to come in to network.it is production server. please provide solution to me , it is very urgent... (2 Replies)
Discussion started by: Rajesh_Apple
2 Replies

3. Solaris

How to enable Serial port on ILOM, when Network Port is enabled in parallel

Hi Everyone, In my environment, I have few T5220. On the iLOM Management Card, I have both Network and Serial port are cabled, I don't have any issues while I try to connect using Network Management port, but when I try to connect the serial port for the same server which is actually connected... (3 Replies)
Discussion started by: bobby320
3 Replies

4. Solaris

configure zones to have different network interface and network

i need to configure a zone to use different interface (bge2) than global and have connected to completely different network switch & to use its own defaultrouter and hosts file .. is it possible ..if so ..how ? Thanks (9 Replies)
Discussion started by: skamal4u
9 Replies

5. UNIX for Dummies Questions & Answers

How to set server's ip address, router, network mask and set if it is an internal or external ip?

Hello, I need to write a program which sets server's ip address, router, network mask. Program also should set if it is an internal or external ip. Maybe someone can help me ? Any information from u is very useful :b: I stopped at .. :( #!/bin/sh A=`hostname -i` echo "server ip address is $A"... (4 Replies)
Discussion started by: zagaruika
4 Replies

6. Solaris

Configure ILOM from network

HI, Is it possible to set up ILOM from the ethernet terminal. I 'm at remote location from server so would like to know if i can configure it remotely I'm able to access my server via ssh terminal. (3 Replies)
Discussion started by: fugitive
3 Replies

7. Solaris

how to configure network in solaris 10?

Hi..i have installed solaris 10 on vmware. I m not able connect to internet. pls help in detail. how to solve the problem. During the installation i have put no DHCP. cofigured manually ( Ip 192.168.1.9) default gateway 192.168.1.1 . (3 Replies)
Discussion started by: johnavery
3 Replies

8. HP-UX

HP-UX 10.20 Network Configure

Hi I'm new about UNIX, but I've to use a HP9000 with HP-UX 10.20 workstation. I'm trying to configure the network, I've configured the file /etc/rc.conf.d/netconf with my IP address and the right gateway, so the HP9000 is on the net, I've tried a ping. But now I've a problem I can't start hte CDE,... (4 Replies)
Discussion started by: gofmass
4 Replies

9. Solaris

[need help] error after configure network card at v890 sparc

hi experts, i have some problem with my server v890, i had config the network with ce0,ce1 and eri0 but after reboot the server have this error messages display : WARNING: ce0: fault detected external to device; service degraded WARNING: ce0: xcvr addr:0x01 - link down configuring IPv4... (2 Replies)
Discussion started by: bucci
2 Replies

10. Cybersecurity

Unable to configure samba on linux 7.1

Hello I am able to connect from Linux machine to Windows machine, but i can not connect from Windows to Linux. Even i can print also from linux to windows... what could be the problem... pl help. thanks (5 Replies)
Discussion started by: twadkar
5 Replies
Login or Register to Ask a Question
powerman-devices(7)						     powerman						       powerman-devices(7)

NAME
powerman-devices - Powerman Device Configuration Notes DESCRIPTION
Following are notes on configuring various remote power controllers and related equipment supported by PowerMan. CYCLADES TS-1000 A cyclades TS-1000 configured so that PowerMan can connect to serial-port-based remote power control devices using telnet is set up as fol- lows: Attach console cable between laptop running minicom and console port at 9600,8n1 and authenticate with default account: root/tslinux. Edit the following files (assumes no off-subnet routing or name service required): /etc/portslave/portslave.conf conf.eth_ip 192.168.54.151 conf.eth_mask 255.255.255.0 conf.dhcp_client 0 # all.speed 9600 all.datasize 8 all.stopbits 1 all.parity none all.flow none all.dcd 0 all.DTR_reset 1 all.protocol socket_server all.authtype none #all.ipno all.socket_port 7001+ # s1.tty ttyS1 s2.tty ttyS2 s3.tty ttyS3 s4.tty ttyS4 s5.tty ttyS5 s6.tty ttyS6 s7.tty ttyS7 s8.tty ttyS8 s9.tty ttyS9 s10.tty ttyS10 s11.tty ttyS11 s12.tty ttyS12 s13.tty ttyS13 s14.tty ttyS14 s15.tty ttyS15 s16.tty ttyS16 /etc/hostname cyclades-ts-test /etc/hosts 127.0.0.1 localhost 192.168.54.151 cycaldes-ts-test Next, run signal_ras hup and saveconf and finally, power cycle the unit. It should be possible to configure PowerMan to connect to host- name:7001 for port 1, hostname:7002 for port 2, etc.. BAYTECH RPC-3 (non-NC models) (network port 23) Attach console cable between laptop running minicom and console port at 9600,8n1. Main menu should display. From main menu, select 3)...Configuration, then set IP parameters. From Configuration menu, select 5)...Access, then disable command confirmation, set admin password to baytech, and enable prompt for pass- word. Exit Access menu by typing return. From Configuration menu, select 6)...Outlets. Ensure that 1)...Outlet Status display is disabled, and 2)...Command Confirmation is dis- abled. Exit back to main menu by typing return twice, then answer Y to the Accept changes? prompt. BAYTECH RPC-28-NC (serial 9600,8n1) Attach console cable between laptop running minicom and console port at 9600,8n1. Type return to get RPC-28> prompt. Type Help for a list of commands. Select config. Select 3)...Enable/Disable Confirmation and disable confirmation. Select 4)...Enable/Disable Status Menu and disable sta- tus menu LNXI ICEBOX V2 (network port 1010) Attach console cable between laptop running minicom and console port at 9600,8n1. Enter default password of icebox. net ip 192.168.54.153 Sets IP address. net mask 255.255.255.0 Sets network mask net gw 192.168.54.254 Set default gateway. Note: this may need to be set to an address in the same subnet as the ice box regardless of whether it is to be used or not. reboot Reboots the icebox. LNXI ICEBOX V3 (network port 1010) Attach console cable between laptop running minicom and console port at 9600,8n1. Authenticate with default account admin/icebox. Config- uration is the same as the V2 ICE BOX. APC MASTERSWITCH MODEL AP9606 (network port 23) Attach console cable between laptop running minicom and console port (may be labeled ``advanced port'') at 2400,8n1. Press enter, then authenticate with default account apc/apc. Choose Network from main menu. Choose TCP/IP from Network menu, then diable BOOTP, and accept changes. Set the IP address, subnet mask, and default gateway, and accept changes. Pres ESC until the main menu appears, then select Logout. WTI RPS10 (serial 9600,8n1) Set address of box using the rotary dial on the back. The Master module must be set to address 0. Slave modules may be set to unique val- ues from 1-9. The address corresponds to the plug name in the powerman.conf file. Setup switches on each module should be set to 9600 baud (sw1 down), 5 sec toggle delay (sw2 down), power up to previous state (sw3 down). WTI NPS (network port 23) Attach console cable between laptop running minicom and console port at 9600,8n1. Try password "wti" if prompted. Select /N - View/set network parameters, then set the IP address, subnet mask, and gateway. Select /G - General paramters, then disable command confirmation, enable command echo, and set disconnect timeout to the maximum value (30 minutes). Set password to "wti". CYCLADES PM8 and PM8i (serial 9600,8n1) Attach console cable between laptop running minicom and serial port 9600,8n1. Press enter, then authenticate with default account admin/pm8. Run factory_defaults command. The PM8 can run in a mode where it can be daisy chained from a Cyclades terminal server. This mode is not yet supported by PowerMan. Sun ILOM The dedicated ILOM serial port (SER MGT RJ-45) runs at 9600,8n1 and the default login is root/changeme. Use a Sun/NETRA/Cisco RJ45 adapter to connect to Cyclades TS. The dedicated ILOM ethernet port (NET MGT RJ-45) can be configured for DHCP (the default) or static IP settings. To configure static IP via the ILOM serial port, run: cd /SP/network set pendingipdiscovery=static set pendingipaddress=xxx.xxx.xxx.xxx set pendingipnetmask=xxx.xxx.xxx.xxx set pendingipgateway=xxx.xxx.xxx.xxx set commitpending=true The ILOM network configuration can alternatively be set up via the system BIOS setup screen. Hit F2 during boot to access BIOS setup, go to the "Advanced" tab, select "IPMI 2.0 configuration" and "set LAN configuration". Make your changes and commit them. IPMI (via Ipmipower) IPMI based power control is supported via FreeIPMI's ipmipower. It is configured by running ipmipower in coprocess mode in powerman.conf Due to semantic differences between IPMI and traditional remote power control devices, some power control operations may not seem to work properly by default with Powerman. For example, several IPMI power control operations are allowed to return prior to the operation fully completing. A machine that has been powered off by IPMI may be later queried as being powered on. This is because IPMI may successfully return from a power off operation to the user, but the machine may elect to power itself off at a later time. In order to get around sev- eral of these issues, it is recommended that the user configure ipmipower with the --wait-until-on and --wait-until-off options. With these options set, ipmipower will behave more like traditional remote power control devices. In order to hide IPMI usernames and passwords from ps(1), it is also recommended that the user configure the username and password (and at your discretion, the above options) using the FreeIPMI configuration file and not in the powerman.conf file. Please see the ipmipower sec- tion of the freeipmi.conf(5) manpage for more information. Because IPMI usernames and passwords are sensitive, the default FreeIPMI configuration file is only readable and writable by root. This may conflict with the default powermand daemon settings, thus making the configuration file non-readable. Administrators may wish to run the powermand daemon as root or adjust the configuration file permissions as needed. HP iLO The "hpilo" script supports the Integrated Lights-Out management processor in HP ProLiant servers, including both rack-mount and blade servers. Configure the iLO to allow Telnet access on port 23, and add a user "Admin" with password "Admin". You may have to reduce the minimum password length on the Administration/Access/Options tab of the web interface. HP MP
The "hpmp" script supports the Management Processor in HP non-cellular, rack-mount Integrity servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". If the MP enforces a minimum password length, you may have to use "uc -all default" to restore the default Admin/Admin user. HP MP (cellular) The "hpmpcell" script supports the Management Processor in HP mid-range cellular servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". HP MP (Superdome) The "hpmpdome" script supports the Management Processor in HP Superdome servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". HP MP (Integrity blades) The "hpmpblade" script supports the Management Processor in HP Integrity blade servers. Configure the MP to allow Telnet access with the "CM:SA" command, and make sure there's a user "Admin" with password "Admin". ORIGIN
PowerMan was originally developed by Andrew Uselton on LLNL's Linux clusters. This software is open source and distributed under the terms of the GNU GPL. SEE ALSO
powerman(1), powermand(8), httppower(8), plmpower(8), vpcd(8), powerman.conf(5), powerman.dev(5), powerman-devices(7). http://sourceforge.net/projects/powerman powerman-2.3.5 2009-02-09 powerman-devices(7)