Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

scshutdown(1m) [opensolaris man page]

scshutdown(1M)						  System Administration Commands					    scshutdown(1M)

NAME
scshutdown - shut down a cluster SYNOPSIS
scshutdown [-y] [-g grace-period] [message] DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scshutdown utility shuts down an entire cluster in an orderly fashion. Before starting the shutdown, scshutdown sends a warning message, then a final message asking for confirmation. Only run the scshutdown command from one node. The scshutdown command performs the following actions when it shuts down a cluster: o Changes all functioning resource groups on the cluster to an offline state. If any transitions fail, scshutdown does not com- plete and displays an error message. o Unmounts all cluster file systems. If any unmounts fail, scshutdown does not complete and displays an error message. o Shuts down all active device services. If any transition of a device fails, scshutdown does not complete and displays an error message. o Runs /usr/sbin/init 0 on all nodes. See init(1M) for more information. You can use this command only in the global zone. You need solaris.cluster.system.admin RBAC authorization to use this command. See rbac(5). OPTIONS
The following options are supported: -g grace-period Changes the number of seconds from the 60-second default to the time specified by grace-period. -y Pre-answers the confirmation question so the command can be run without user intervention. OPERANDS
The following operands are supported: message Is a string that is issued after the standard warning message The system will be shut down in ... is issued. If message contains more than one word, delimit it with single (') or double (") quotation marks. The warning message and the user-provided message are output when there are 7200, 3600, 1800, 1200, 600, 300, 120, 60, and 30 seconds remaining before scshutdown begins. EXAMPLES
Example 1 Shutting Down a Cluster phys-palindrome-1# scshutdown EXIT STATUS
The following exit values are returned: 0 The command completed successfully. nonzero An error occurred. Error messages are displayed on the standard output. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cluster(1CL), shutdown(1M), init(1M), attributes(5) Sun Cluster 3.2 10 Apr 2006 scshutdown(1M)

Check Out this Related Man Page

scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
Man Page