Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

scconf_transp_adap_hme(1m) [opensolaris man page]

scconf_transp_adap_hme(1M)				  System Administration Commands				scconf_transp_adap_hme(1M)

NAME
scconf_transp_adap_hme - configure the hme transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure hme Ethernet adapters as cluster transport adapters. These adapters can only be used with transport type dlpi. The hme Ethernet adapter connects to a transport switch or to another Ethernet adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), hme(7D) Sun Cluster 3.2 18 Jul 2006 scconf_transp_adap_hme(1M)

Check Out this Related Man Page

scconf_transp_adap_bge(1M)				  System Administration Commands				scconf_transp_adap_bge(1M)

NAME
scconf_transp_adap_bge - configure the bge transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure bge adapters as cluster transport adapters. These adapters can only be used with the dlpi transport type. The bge adapter is VLAN capable. The bge adapter connects to a transport switch or to another bge adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured by using the scconf command, the scinstall command, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), bge(7D) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_bge(1M)
Man Page

15 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Sun Hardware Diag Tools

Problem: Several possible cooked Sun U10's. Need: Sun Hardware Diag Tools. I want to pound on these boxes and see whats what. I am wondering where I could find some Diag tools that will help me diag problems. Freeware is preferred. (The magic budget of $0) (7 Replies)
Discussion started by: edkung
7 Replies

2. Solaris

SUN E250 Cluster

Hi, I need some help, since I am new to cluster. I am handling a site where I have look after two SUN E250 server. I have been asked to configure Active-Active Clustering on these servers. I would like to know how to configure both the servers for clustering. Below are the things which... (5 Replies)
Discussion started by: RajaRC
5 Replies

3. Solaris

Config reader module in Sun MC Agent not work in E2900

Hi men, Have you ever meet this error ? I install full Sun MC 4.0 packages (+ Add ons) exception of Sun Midrange Platform Administration because i don't know how to configure it Then all other servers are ok, only E2900 servers have Config reader module error: Data Acquisition error I... (12 Replies)
Discussion started by: tien86
12 Replies

4. High Performance Computing

Benchmarking a Beowulf Cluster

Hi guys. I am trying to test my universities cluster using the Intel Linpack Benchmarking software. Let me say from the get-go that i am a Linux novice, and only recently learnt some Linux commands to have a play around, so if you can please keep the language simple :) I have run a Linpack test... (17 Replies)
Discussion started by: mercthunder
17 Replies

5. Emergency UNIX and Linux Support

Sun Cluster-Metaset problem

Hi Guys i have two servers which are n cluster prd1 and prd2.. I already have a metaset configured in it..My job was to create a 1.8 tb LUN in my storage which is having Hardware raid5 pre-configured..i Created 1.8 tb with raid 5 in my storage and it got detected in both t servers... (5 Replies)
Discussion started by: madanmeer
5 Replies

6. Emergency UNIX and Linux Support

Rebooting 3 to 1 Cluster nodes.

hello Gurus, My current set up is 3 to 1 Cluster (SUN Cluster 3.2) running oracle database. Task is to reboot the servers. My query is about the procedure to do the same. My understanding is suspend the databases to avoid switchover. Then execute the command scshutdown to down the cluster... (4 Replies)
Discussion started by: EmbedUX
4 Replies

7. Solaris

Is Sun Cluster works for zones?

Hi, I want to know is Sun Cluster works for Zones. These Zones are configured on the same OS? Is Sun Cluster available for x86(Non Sparc) (4 Replies)
Discussion started by: malikshahid85
4 Replies

8. Solaris

Sun Cluster 3.1 failover

Hi, We have two sun SPARC server in Clustered (Sun Cluster 3.1). For some reason, System 1 failed over to System 2. Where can I find the logs which could tell me the reason for this failover? Thanks (5 Replies)
Discussion started by: Mack1982
5 Replies

9. Solaris

Find Brocade SAN switch’s IP in Sun server?

We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
Discussion started by: aixlover
6 Replies

10. AIX

How to set 4 SEA on single VIOS

Hi experts, i got a 4-port Adapter card on VIOS and would like to configure 4SEA for 4 difference segment IP client's LPAR use, first SEA succeed to be configured on ent0 but once second SEA configured, first SEA fail to be connected. Any issues i need to be concerned in order to configure 4 SEA on... (8 Replies)
Discussion started by: polar
8 Replies

11. UNIX for Advanced & Expert Users

Veritas Cluster automatic fail-back option on Solaris

Hi - Please help me to understand the Veritas Cluster fail-over capability. We configured oracle database file system on veritas cluster file system and it is automatically failing-over from node 1 to node 2. Does Veritas cluster softward have any option to fail-back from node 2 to node 1... (6 Replies)
Discussion started by: Mansoor8810
6 Replies

12. Solaris

M5000 splitting existing domain

Hi We have an M5000 with one domain running Sun Cluster on it. We would like to split the domain into two domains. One with the existing Sun Cluster and one with a fresh install. We have 2 CPU Boards (8 CPU) / 4 Mem Boards (64 gb memory) and 2 IOU as well as 4 disks Is it possible to have... (9 Replies)
Discussion started by: sanc
9 Replies

13. Solaris

Sun Cluster/Storage question

Hi Bros, I am a newbie to this cluster environment...my workplace is a mess of Sun solaris server, oracle database, Cisco switch, router, MS Server, Windows PC..so and so..now my boss ask me to come out with a procedure for maintenance of storage array in our sun cluster environment..I read few... (12 Replies)
Discussion started by: xavierantony
12 Replies

14. HP-UX

Status of hardware in HpUx

We would like to know a HP Utility or any Unix command that can give the exact status of PCI Gigabit Ethernet cable (lan cable) We had tried to execute lanscan ioscan -fnC lan The status appears to be the same when the cable is plugged & unplugged and also when the lan is disabled &... (5 Replies)
Discussion started by: siva3492
5 Replies

15. AIX

ISCSI poor performance 1.5MB/s fresh install AIX7.1

Hi Everyone, I have been struggling for few days with iSCSI and thought I could get some help on the forum... fresh install of AIX7.1 TL4 on Power 710, The rootvg relies on 3 SAS disks in RAID 0, 32GB Memory The lpar Profile is using all of the managed system's resources. I have connected... (11 Replies)
Discussion started by: frenchy59
11 Replies