Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

sg_rmsn(8) [debian man page]

SG_RMSN(8)							     SG3_UTILS								SG_RMSN(8)

NAME
sg_rmsn - sends a SCSI READ MEDIA SERIAL NUMBER command SYNOPSIS
sg_rmsn [--help] [--raw] [--readonly] [--verbose] [--version] DEVICE DESCRIPTION
Send a SCSI READ MEDIA SERIAL NUMBER command to DEVICE and outputs the response. This command is described in SPC-3 found at www.t10.org . It was originally added to SPC-3 in revision 11 (2003/2/12). It is not an manda- tory command and the author has not seen any SCSI devices that support it. OPTIONS
Arguments to long options are mandatory for short options as well. -h, --help output the usage message then exit. -r, --raw sends the serial number (if found) to stdout. This output may contain non-printable characters (e.g. the serial number is padded with NULLs at the end so its length is a multiple of 4). The default action is to print the serial number out in ASCII-HEX with ASCII characters to the right. All error messages are sent to stderr. -R, --readonly opens the DEVICE read-only rather than read-write which is the default. The Linux sg driver needs read-write access for the SCSI READ MEDIA SERIAL NUMBER command but other access methods may require read-only access. -v, --verbose increase the level of verbosity, (i.e. debug output). -V, --version print the version string and then exit. NOTES
Device identification information is also found in a standard INQUIRY response and its VPD pages (see sg_vpd). The relevant VPD pages are the "device identification page" (VPD page 0x83) and the "unit serial number" page (VPD page 0x80). The MMC-4 command set for CD/DVD/HD-DVD/BD drives has a "media serial number" feature (0x109) [and a "logical unit serial number" feature]. These can be viewed with sg_get_config. EXIT STATUS
The exit status of sg_rmsn is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2005-2011 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_vpd(sg3_utils), sg_get_config(sg3_utils) sg3_utils-1.31 February 2011 SG_RMSN(8)

Check Out this Related Man Page

SG_IDENT(8)							     SG3_UTILS							       SG_IDENT(8)

NAME
sg_ident - send SCSI REPORT/SET IDENTIFYING INFORMATION command SYNOPSIS
sg_ident [--ascii] [--clear] [--help] [--itype=IT] [--raw] [--set] [--verbose] [--version] DEVICE DESCRIPTION
Send a SCSI REPORT IDENTIFYING INFORMATION or SET IDENTIFYING INFORMATION command to DEVICE. Prior to SPC-4 (revision 7) these commands were called REPORT DEVICE IDENTIFIER and SET DEVICE IDENTIFIER respectively. SCSI devices that support these two commands allow users to write (set) identifying information and report it back at some later time. The information is persistent (i.e. stored on some non-volatile medium within the SCSI device that will survive a power outage). Typically the space allocated for the information is limited: SPC-4 (revision 7) states that for information type 0, the minimum length is 64 bytes and the maximum is 512 bytes. For other information types (1 to 126 inclusive) the maximum length is 256 bytes. Also information types 1 to 126 (inclusive) should contain a null terminated UTF-8 string. The author has seen older disks that only support 16 bytes. The default action when no options are given is to invoke the Report Identifying Information command with the information type defaulting to zero. Error reports are sent to stderr. By default the information is shown in ASCII-HEX (up to 16 bytes per line) with an ASCII repre- sentation to the right with dots replacing non printable characters. OPTIONS
Arguments to long options are mandatory for short options as well. -A, --ascii invokes the Report Identifying Information command and if anything is found interprets it as ASCII (or UTF-8 depending on the locale) and prints the information to stdout. -C, --clear invokes the Set Identifying Information command with an information length of zero. This has the effect of clearing the existing information. -h, --help output the usage message then exit. -i, --itype=IT where IT is the information type. Defaults to zero. The maximum value is 127 which is special and cannot be used with --set or --clear. The information type of 127 (if supported) causes the REPORT IDENTIFYING INFORMATION command to respond with a list of available information types and their maximum lengths in bytes. The odd numbered information types between 3 and 125 (inclusive) are not to be used (as they clash with the SCC-2 standard). -r, --raw invokes the Report Identifying information command and if anything is found sends the information (which may be binary) to stdout. Nothing else is sent to stdout however error reports, if any, are sent to stderr. -S, --set first reads stdin until an EOF is detected then invokes the Set Identifying Information command to set what has been fetched from stdin as the information. The amount of data read must be between 1 and 512 bytes length (inclusive). -v, --verbose increase the level of verbosity, (i.e. debug output). -V, --version print the version string and then exit. This utility permits users to write their own identifying information to their SCSI devices. There are several other types of descriptors (or designators) that the user cannot change. These include the SCSI INQUIRY command with its standard vendor and product identification strings and the product revision level; plus the large amount of information provided by the "Device Identification" VPD page (see sg_vpd). There is also the READ MEDIA SERIAL NUMBER command (see sg_rmsn). The MMC-4 command set for CD and DVDs has a "media serial number" feature (0x109) [and a "logical unit serial number" feature]. These can be viewed with the sg_get_config utility. EXAMPLES
First, to see if there is an existing information whose format is unknown (for information type 0), use no options: # sg_ident /dev/sdb 00 31 32 33 34 35 36 37 38 39 30 1234567890 If it is ASCII then it can printed as such: # sg_ident --ascii /dev/sdb 1234567890 The information can be copied to a file, cleared and then re-asserted with this sequence: # sg_ident --raw /dev/sdb > t # sg_ident --clear /dev/sdb # cat t | sg_ident --set /dev/sdb EXIT STATUS
The exit status of sg_ident is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2005-2012 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_vpd(sg3_utils), sg_rmsn(sg3_utils), sg_get_config(sg3_utils) sg3_utils-1.35 November 2012 SG_IDENT(8)