I have checked the state of rmc on the HMC as below:
But I check on my AIX lpar, the rmc is still active
I am still finding the way to check on VIOS rmc state.
so, why the HMC cannot detect the rmc state.
What I can do to get HMC see the state of lpar rmc state. Please advise.
I found the reason, it's because I took out the ethernet adapter, so the partitions don't have the IP.
Naturally, I think HMC can connect to it LPARs by its own method, but instead it uses IP to connect.
After I assign the adapter again, the rmc state is active.
Hey All,
I have running dual VIOS on a P9 systems, and just created a new LPAR profile. My objective is to create LPAR Client VFC adapters, and then DLPAR VFC Server adapters on the VIOS.
In the HMC v9 Enhanced GUI, I have DLPAR a VFC adapter to both VIOS, however, you can't specify the... (1 Reply)
There can be configurations in IBM Server wherein a
standalone partition is created on some supported IBM Server
Or
A VIOS - VIOC LPARs created.
Now in both cases they are lpars. But if I want to differentiate b/w a standalone LPAR vs an VIOC LPAR how can I do..?
On a... (2 Replies)
Hi all,
is any of you using RMC for monitoring your LPARs? Is it viable?
I know the IBM Magazine article and the Redbooks about it but I would like to hear from first hand.
Thanks in advance for sharing your experience! (7 Replies)
I cannot find the post with the comment that DLPAR capability was not working with IVM.
The two commands that need to be run are (as root, padmin does not know this command):
VIOS: lsrsrc IBM.MngNode
CLIENTS: lsrsrc IBM.MCP
Examples:
# lsrsrc IBM.MngNode
Resource Persistent Attributes for... (2 Replies)
I am trying to generate a report to track dlpar operation performed on a MS and was wondering if anyone has done this before.
I can get history from HMC using lssvcevents , but this does not give me details as to what quantity was added or removed .
Any thoughts ?
Thanks (3 Replies)
Hi all,
I have the following configuration
2 ds3524 storage disk systems located over 2 locations
2 P720 server located over 2 locations
DS3524 are connected to san switch.
Each vio server has 1 fc adapter attached to a san switch.
per p720 server 2 virtual io servers. Vio 1 has 1 lun... (2 Replies)
Hello,
This is the foll error wen i try doin DLPAR from my VIO after adding the virtual adpaters on my clients:
HSCL294C DLPAR ADD Virtual I/O resources failed:
com.ibm.hsc.common.exceptions.PIHscClientException: HSCL294C DLPAR ADD Virtual I/O... (0 Replies)
Hi,
Anybody had a problem trying to rmdev a scsi device and get the following error :
root@:/> rmdev -dlscsi3 -R
Method error (/usr/lib/methods/ucfgncr_scsi):
0514-062 Cannot perform the requested function
because the specified device is busy.