actually powerha doesnt overly care if its on one or two frames - it doesnt check the underlying system. But for the obvious reasons (if your frame goes down, your cluster does too) it might not be such a great idea
Yes I see thats not real cluster solution but anyway it's good for DB start stop automation, as for future we will buy another Server to have real PowerHA environment :-)))
HI,
How do we figure out if the server is half blade server or full blade server?
Anything we need to look at to know on this?
thanks in advance (9 Replies)
Hi,
I require help with hardware discovery while running a command from an HMC with firmware V7.3.5 SP 3. The two frames I am running the command for are p 5 595's.
Command input: lshwres -m swdc-c02-9119-595-SN02780CF -r io --rsubtype slotchildren -F lpar_name
Error output: The managed... (1 Reply)
Hi,
We have a P595 machine with a dual port Fiber card per VIOs.
We have two VIOs in the box.
VIO1: ---> 2 port Fiber Card
VIO2: ---> 2 port Fiber Card
One port on each fiber card is utilized. Connected to SAN switches. We are getting all disks from SAN both for VIOs and LPARs.
Now... (0 Replies)
Hello, we have a wierd and urgent problem, with a few of our p595 LPARs running AIX 5.3. The LPARs ran AIX 5.3 TL 7 and booted off EMC SAN disks, using EMC Powerpath. Every boot we run "pprootdev on" and "pprootdev fix". We can issue "bosboot -a" and we can reboot the machines.
Now, on two... (2 Replies)
The p595 have 6 Lpars, not all hardware resource assigned to 6 lpars.
which command can list all hardware configuration on p595? Do I need go to each lapr to list? (2 Replies)