I terribly need help in setting up RAID 5 for a P615 IBM server. IBM said that I needed a diagnostic cd but it will take them 6 weeks to send it to me. I need help PLEASE
Server configuration:
P615 IBM Server
3 pcs 36.4GB HDD
Dual Channel SCSI RAID Enab. Card
Hello All,
Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ?
Am having AIX 6.1 and EMC clarion 5.5.
Regards,
Gowtham.G (3 Replies)
Hello,
I want to delete a RAID configuration an old server has.
Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton?
I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
HI I am trying to create an X Server on my laptop for displaying X Applications from an AIX platform.
Normally I would just use the Exceed Client Wizard to create my X Server on my laptop. However I am told that this by default creates X Servers that use REXEC as the communication over TCP/IP (... (1 Reply)
Hi everyone.
I have a machine which upon to recently only had one hard disk. Now I have another one identical in size and speed and want create a raid set from those two.
The partition layout is that I have three partitions, first one for /boot, the second for / and then a huge LVM partition... (1 Reply)
Hi there,
I'm not sure if this is possible, but here is what I'd like to do..
I have an existing 160GB drive in my Redhat 9.0 server that I would like to add an additional 160GB drive to and create a mirrored RAID of the first disk to the new disk. I would like to do this without having to... (2 Replies)
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD March 3, 2008 BSD