Sponsored Content
Full Discussion: Raid5 Failure
Operating Systems SCO Raid5 Failure Post 99769 by Perderabo on Tuesday 21st of February 2006 11:56:16 AM
Old 02-21-2006
All drives in a raid 5 should generally be identical and must be identical in size. I don't know what an adaptec controller is, but when you replace the drive, you must rebuild the lost info. I would expect any utility to lead you in that direction. A backup would be wise.
 

10 More Discussions You Might Find Interesting

1. AIX

Can not increase capacity of the vg using raid5 with ssa disks

hi all, i have an p620 server. it has 2 scsi 18gb disks for aix4.3 OS and 3 ssa disks for database and an serialRAID adapter. 3 ssa disks configured raid level 5. to increase capacity of the datavg, i buy 2 ssa 18gb disks. but i can not add them to the existing datavg. i did the following... (1 Reply)
Discussion started by: tinhlx
1 Replies

2. Solaris

RAID5 problems on solaris

I have one volume raid5 with 3 slice one of them is maintenance state. I replace this slice and resync the volume. when I try to mount the file system another slice goes to last erred. Again resync and the state goes to OK but the slice in mantenance persist. I try to enabled this but persist in... (2 Replies)
Discussion started by: usdsia
2 Replies

3. AIX

Software-based RAID5 on Aix

Hello All. Is it possible? (5 Replies)
Discussion started by: sapbcer
5 Replies

4. AIX

how to mirror raid5

Hi, I have an ssa filesystem to move to san. We don't want any downtime. I heard that you can do a mirroring of existing file system on the san. The file system is a type of either raid 0, raid 1, or raid 5. Anyone know how to do this? Thanks in advance, itik (4 Replies)
Discussion started by: itik
4 Replies

5. Filesystems, Disks and Memory

Problem booting a linux (RAID5)

Hello, we have a problem with our system, a machine with a RAID5: - We can boot the system from CD only, if we try to boot from hard-disk the GRUB seems to be "freezed". What is the difference, why we can boot from CD if something is wrong? - Allways we retreive an error like: "raid array is... (6 Replies)
Discussion started by: aristegui
6 Replies

6. UNIX for Advanced & Expert Users

RAID5 multi disk failure

Hi there, Don't know if my title is relevant but I'm dealing with dangerous materials that I don't really know and I'm very afraid to mess anything up. I have a Debian 5.0.4 server with 4 x 1TB hard drives. I have the following mdstat Personalities : md1 : active raid1 sda1 sdd1... (3 Replies)
Discussion started by: chebarbudo
3 Replies

7. SuSE

Raid5

Hi all, I am currently using opensuse 12.1, We have Raid 5 array of 8 disks. A friend of mine accidently removed a drive & place it back and also added a new disk to it(making it 9 disks). now the output of mdadm --detail is as shown below si64:/dev # mdadm --detail /dev/md3 /dev/md3:... (1 Reply)
Discussion started by: patilrajashekar
1 Replies

8. UNIX for Dummies Questions & Answers

boot up failure unix sco after power failure

hi power went out. next day unix sco wont boot up error code 303. any help appreciated as we are clueless. (11 Replies)
Discussion started by: fredthayer
11 Replies

9. Hardware

RAID5 + STRIPED LUNs

Hello Experts, I have few doubts on RAID 5 with LUNs carved as STRIPE and CONCAT RAID 5 = STRIPE + Parity mirroring I would like to know if the LUNs carved are CONCATE from RAID 5 disk array. Are the I/Os are spread accross the disks within the RAID 5 Array? And if I do carve STRIPED... (1 Reply)
Discussion started by: sybadm
1 Replies

10. Red Hat

Install RHEL6 on x3650M4 with RAID5

Hi All, I have a new x3650 M4 server with hardware RAID 5 configured 4 x 300 GB (HDD). The Raid controller is ServeRAID M5110e. Im getting "device not found" error during hardisk detection of RHEL6 install using DVD. Some pages over the net pointed to using ServerGuide media for... (1 Reply)
Discussion started by: Solaris_Begin
1 Replies
MLY(4)							   BSD Kernel Interfaces Manual 						    MLY(4)

NAME
mly -- Mylex AcceleRAID/eXtremeRAID family driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device da device mly Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mly_load="YES" DESCRIPTION
The mly driver provides support for Mylex AcceleRAID and eXtremeRAID-family PCI to SCSI RAID controllers with version 6.00 and later firmware. Logical devices (array drives) attached to the controller are presented to the SCSI subsystem as though they were direct-access devices on a virtual SCSI bus. Physical devices which are not claimed by a logical device are presented on SCSI channels which match the physical chan- nels on the controller. HARDWARE
Controllers supported by the mly driver include: o Mylex AcceleRAID 160 o Mylex AcceleRAID 170 o Mylex AcceleRAID 352 o Mylex eXtremeRAID 2000 o Mylex eXtremeRAID 3000 Compatible Mylex controllers not listed should work, but have not been verified. DIAGNOSTICS
Controller initialisation phase mly%d: controller initialisation started mly%d: initialisation complete The controller firmware has started initialisation. Normally this process is performed by the controller BIOS, but the driver may need to do this in cases where the BIOS has failed, or is not compatible (e.g. on non-x86 systems). mly%d: drive spinup in progress Drive startup is in progress; this may take several minutes. mly%d: mirror race recovery failed, one or more drives offline mly%d: mirror race recovery in progress mly%d: mirror race recovery on a critical drive These error codes are undocumented. mly%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mly%d: unknown initialisation code %x An unknown error occurred during initialisation; it will be ignored. Driver initialisation/shutdown phase mly%d: can't enable busmaster feature mly%d: memory window not available mly%d: can't allocate register window mly%d: can't allocate interrupt mly%d: can't set up interrupt The system's PCI BIOS has not correctly configured the controller's PCI interface; initialisation has failed and the driver will not attach to this controller. mly%d: can't allocate parent DMA tag mly%d: can't allocate buffer DMA tag mly%d: can't allocate command packet DMA tag mly%d: can't allocate scatter/gather DMA tag mly%d: can't allocate s/g table mly%d: can't allocate memory mailbox DMA tag mly%d: can't allocate memory mailbox A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. mly%d: BTL rescan result corrupted The results of a scan for an attached device were corrupted. One or more devices may not be correctly reported. mly%d: flushing cache... The controller cache is being flushed prior to detach or shutdown. Operational diagnostics mly%d: physical device %d:%d online mly%d: physical device %d:%d standby mly%d: physical device %d:%d automatic rebuild started mly%d: physical device %d:%d manual rebuild started mly%d: physical device %d:%d rebuild completed mly%d: physical device %d:%d rebuild cancelled mly%d: physical device %d:%d rebuild failed for unknown reasons mly%d: physical device %d:%d rebuild failed due to new physical device mly%d: physical device %d:%d rebuild failed due to logical drive failure mly%d: physical device %d:%d found mly%d: physical device %d:%d gone mly%d: physical device %d:%d unconfigured mly%d: physical device %d:%d expand capacity started mly%d: physical device %d:%d expand capacity completed mly%d: physical device %d:%d expand capacity failed mly%d: physical device %d:%d parity error mly%d: physical device %d:%d soft error mly%d: physical device %d:%d miscellaneous error mly%d: physical device %d:%d reset mly%d: physical device %d:%d active spare found mly%d: physical device %d:%d warm spare found mly%d: physical device %d:%d initialization started mly%d: physical device %d:%d initialization completed mly%d: physical device %d:%d initialization failed mly%d: physical device %d:%d initialization cancelled mly%d: physical device %d:%d write recovery failed mly%d: physical device %d:%d scsi bus reset failed mly%d: physical device %d:%d double check condition mly%d: physical device %d:%d device cannot be accessed mly%d: physical device %d:%d gross error on scsi processor mly%d: physical device %d:%d bad tag from device mly%d: physical device %d:%d command timeout mly%d: physical device %d:%d system reset mly%d: physical device %d:%d busy status or parity error mly%d: physical device %d:%d host set device to failed state mly%d: physical device %d:%d selection timeout mly%d: physical device %d:%d scsi bus phase error mly%d: physical device %d:%d device returned unknown status mly%d: physical device %d:%d device not ready mly%d: physical device %d:%d device not found at startup mly%d: physical device %d:%d COD write operation failed mly%d: physical device %d:%d BDT write operation failed mly%d: physical device %d:%d missing at startup mly%d: physical device %d:%d start rebuild failed due to physical drive too small mly%d: physical device %d:%d sense data received mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D mly%d: physical device %d:%d offline mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D The reported event refers to the physical device at the given channel:target address. mly%d: logical device %d (%s) consistency check started mly%d: logical device %d (%s) consistency check completed mly%d: logical device %d (%s) consistency check cancelled mly%d: logical device %d (%s) consistency check completed with errors mly%d: logical device %d (%s) consistency check failed due to logical drive failure mly%d: logical device %d (%s) consistency check failed due to physical device failure mly%d: logical device %d (%s) automatic rebuild started mly%d: logical device %d (%s) manual rebuild started mly%d: logical device %d (%s) rebuild completed mly%d: logical device %d (%s) rebuild cancelled mly%d: logical device %d (%s) rebuild failed for unknown reasons mly%d: logical device %d (%s) rebuild failed due to new physical device mly%d: logical device %d (%s) rebuild failed due to logical drive failure mly%d: logical device %d (%s) offline mly%d: logical device %d (%s) critical mly%d: logical device %d (%s) online mly%d: logical device %d (%s) initialization started mly%d: logical device %d (%s) initialization completed mly%d: logical device %d (%s) initialization cancelled mly%d: logical device %d (%s) initialization failed mly%d: logical device %d (%s) found mly%d: logical device %d (%s) gone mly%d: logical device %d (%s) expand capacity started mly%d: logical device %d (%s) expand capacity completed mly%d: logical device %d (%s) expand capacity failed mly%d: logical device %d (%s) bad block found mly%d: logical device %d (%s) size changed mly%d: logical device %d (%s) type changed mly%d: logical device %d (%s) bad data block found mly%d: logical device %d (%s) read of data block in bdt mly%d: logical device %d (%s) write back data for disk block lost The event report will include the name of the SCSI device which has attached to the device if possible. mly%d: enclosure %d fan %d failed mly%d: enclosure %d fan %d ok mly%d: enclosure %d fan %d not present mly%d: enclosure %d power supply %d failed mly%d: enclosure %d power supply %d ok mly%d: enclosure %d power supply %d not present mly%d: enclosure %d temperature sensor %d failed mly%d: enclosure %d temperature sensor %d critical mly%d: enclosure %d temperature sensor %d ok mly%d: enclosure %d temperature sensor %d not present mly%d: enclosure %d unit %d access critical mly%d: enclosure %d unit %d access ok mly%d: enclosure %d unit %d access offline These events refer to external enclosures by number. The driver does not attempt to name the enclosures. mly%d: controller cache write back error mly%d: controller battery backup unit found mly%d: controller battery backup unit charge level low mly%d: controller battery backup unit charge level ok mly%d: controller installation aborted mly%d: controller mirror race recovery in progress mly%d: controller mirror race on critical drive mly%d: controller memory soft ecc error mly%d: controller memory hard ecc error mly%d: controller battery backup unit failed These events report controller status changes. AUTHORS
The mly driver was written by Michael Smith <msmith@FreeBSD.org>. This manual page was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The driver does not yet provide an external management interface. Enclosures are not named or otherwise identified in event messages. BSD
August 10, 2004 BSD
All times are GMT -4. The time now is 06:11 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.