DPT PM2044UW Controller

I have three DPT PM2044UW controllers (no raid modules) that I pulled from working servers. Are you interested?
 

We Also Found This Discussion For You

1. SCO

SCO Unix 5.0.5 lost root password DPT PM2022A/9X

I got a old server that came from another company and nobody knows root password. Server is SCO OpenServer 5.0.5 with DPT PM2022A/9X controller with CM4000 tow hard drives 4G and 1G (So i assume it cannot be raid). I already tried to mount this hard drives on a OpenServer 5.0.6 machine with... (2 Replies)
Discussion started by: Eugene67
2 Replies
dpt(7D) 							      Devices								   dpt(7D)

NAME
dpt - DPT ServeRAID IV SCSI host bus adapter and RAID adapter driver DESCRIPTION
The dpt driver is a driver for the DPT (Distributed Processing Technology) family of SmartRAID IV SCSI HBA and RAID adapters. The following HBA adapters are supported: PM2024, PM2044UW, PM2044W, PM2124, PM2124W, PM2144UW, and PM2144W. The following RAID adapters are supported: PM3224, PM3224W, PM3334UW, and PM3334W. PRECONFIGURATION
o DPT PM3224 only: Only EPROM 7A and later versions are supported. o DPT PM2024 and PM2124 only: Only EPROM 6D4 and later versions are supported. o Use adapters with SmartROM version 3.B or later versions only. o Be sure that the controller board is installed in a PCI bus-mastering slot. o Disable PCI parity checking if your firmware version is earlier than version 7A, if your system memory is ECC, or if your system does not check parity. Known Problems and Limitations During system boot, a message may be displayed saying a DPT controller driver cannot be installed. This message indicates that the mother- board installed in your system may contain ECC memory or may not check parity. If you see this message is displayed, disable PCI parity checking. Supported Settings o I/O Address: Auto CONFIGURATION
Auto-configuration code determines whether the adapter is present at the configured address and what types of devices are attached to it. The DPT ServeRAID is primarily used as a disk array (system drive) controller. To configure the attached disk arrays, you must configure the controller (using the configuration utilities provided by the hardware manu- facturer) before you boot the Solaris operating environment. You use the configuration utilities to set RAID levels, stripe parameters, cache mechanisms and perform other functions. For more information, see the user manual supplied with your hardware. FILES
/kernel/drv/dpt.conf dpt configuration file /dev/dsk/cndn[s|p]n block device /dev/rdsk/cndn[s|p]n raw device where: cn controller n dn LUN n (0-7) sn UNIX system slice n (0-15) pn fdisk(1M) partition(0) ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
fdisk(1M), attributes(5), cmdk(7D) SunOS 5.10 27 November 2000 dpt(7D)