Sponsored Content
Full Discussion: COBOL issue
Operating Systems Solaris COBOL issue Post 92634 by Jayaprakash T on Tuesday 13th of December 2005 09:38:03 AM
Old 12-13-2005
COBOL issue

Hi,

I would like to know whether it takes extra byte in UNIX for COMP-3 fields compared to Mainframe. Please advice.

I have run same program in UNIX and Mainframe hardcoding the values. In UNIX the comp-3 position shifted by one position to the right. I could not figure out the cause. Please advice.
 

10 More Discussions You Might Find Interesting

1. Solaris

Cobol linking in Unix

I'm trying to call a C mod from COBOL but I'm currently having difficulty linking my COBOL program with a C module that I've just developed. I've tried using cbllink -v -l -k -BSF CMPCACVN.cbl test.lib but I've got an error that states cbllink: not found. I've also tried using buildclient -C -w -o... (0 Replies)
Discussion started by: soulfactory2002
0 Replies

2. UNIX for Dummies Questions & Answers

Cobol On Unix

Hi , Could anyone please tell me about the whole procedure for compiling, linking the cobol program on unix platform. As i am mainframe guy and very new to unix, any help will be very appriciated, Regards, -Vinit (2 Replies)
Discussion started by: vinit_cyberguy
2 Replies

3. Gentoo

COBOL on linux?!

Hello guys, I'm searching for a good COBOL compiler which runs on linux. In fact I have found one but I'm really lost with its installation!! I don't know how to install it and how it works. In fact I'm not so good in linux and I always have problems with installation, but this time it's... (1 Reply)
Discussion started by: HSN
1 Replies

4. UNIX and Linux Applications

Rm-cobol 85

Does anyone use the following Cobol compiler: RM/COBOL-85 Compiler - Version 5.15.00 for SCO Unix 386. I am looking for a file that might be part of the distribution named "osmain.o" Thanks. (0 Replies)
Discussion started by: jgt
0 Replies

5. Programming

cobol programme

I have some compile programme .crn now I want to run .crn programme on express cobol which allow only *.gnt programme any solution to run *.crn programme (0 Replies)
Discussion started by: bibi
0 Replies

6. Programming

cobol crn programme run on express cobol as .gnt

can i run .crn programme in express cobol which support to .gnt programme .... Plz tell me solution (2 Replies)
Discussion started by: bibi
2 Replies

7. Shell Programming and Scripting

Calling script from RM cobol and returning value to cobol

Is there a way you can return a value from a script that is called from a rm cobol program... 01 WS-COMD-LINE-PGM X(39) value sh ./getUserId.sh 12345" 01 WS-RETURN-SYS-CODE PIC 9(8). CALL "SYSTEM" USING WS-COMD-LINE-PGM GIVING WS-RETURN-SYS-CODE. ... (1 Reply)
Discussion started by: pavanmp
1 Replies

8. SCO

cobol installation

Dear All, while installing mfcobol in sco open unix 5 in piv m/cs, when run #sh ./install this error massage is comming load error file lmfnewdb error code 198 pc=0 call=-1 seg=0 198 load failor chmod warrning can not acess /opt/lib/mflmf/mflmfdb no such file or directory (error-2)... (0 Replies)
Discussion started by: sudhir69
0 Replies

9. Linux

Cobol on Linux

Hello, I have got a specific requirement of running a COBOL code on EL5. Not sure if GCC includes the compiler for COBOL. Currently what I can think of installing openCOBOL in EL5 server and hand it over to developers. From what I think need to do is, compile COBOL code using openCOBOL ... (5 Replies)
Discussion started by: niravkamdar
5 Replies

10. Programming

cobol compiler for suse

hi could you please suggest me any cobol compiler for suse linux. any help would me much appreciated .. -- thanks rakesh kumar (7 Replies)
Discussion started by: rakeshkumar
7 Replies
tabs(1) 						      General Commands Manual							   tabs(1)

NAME
tabs - set tabs on a terminal SYNOPSIS
[tabspec] n] type] DESCRIPTION
sets the tab stops on the user's terminal according to the tab specification tabspec, after clearing any previous settings. The user's terminal must have remotely-settable hardware tabs. If you are using a non-HP terminal, you should keep in mind that behavior will vary for some tab settings. Four types of tab specification are accepted for tabspec: ``canned'', repetitive, arbitrary, and file. If no is given, the default value is i.e., UNIX ``standard'' tabs. The lowest column number is 1. Note that for tabs, column 1 always refers to the left-most column on a terminal, even one whose column markers begin at 0. Gives the name of one of a set of ``canned'' tabs. Recognized codes and their meanings are as follows: 1,10,16,36,72 Assembler, IBM S/370, first format 1,10,16,40,72 Assembler, IBM S/370, second format 1,8,12,16,20,55 COBOL, normal format 1,6,10,14,49 COBOL compact format (columns 1-6 omitted). Using this code, the first typed character corresponds to card column 7, one space gets you to column 8, and a tab reaches column 12. Files using this tab setup should have specify a format specification file as defined by below. The file should have the following format specification: 1,6,10,14,18,22,26,30,34,38,42,46,50,54,58,62,67 COBOL compact format (columns 1-6 omitted), with more tabs than This is the recommended format for COBOL. The appro- priate format specification is: 1,7,11,15,19,23 FORTRAN 1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61 PL/I 1,10,55 SNOBOL 1,12,20,44 UNIVAC 1100 Assembler In addition to these ``canned'' formats, three other types exist: A repetitive specification requests tabs at columns 1+n, 1+2xn, etc. Of particular importance is the value this represents the UNIX ``standard'' tab setting, and is the most likely tab setting to be found at a terminal. Another special case is the value implying no tabs at all. The arbitrary format permits the user to type any chosen set of numbers, separated by commas, in ascending order. Up to 40 numbers are allowed. If any number (except the first one) is preceded by a plus sign, it is taken as an increment to be added to the previous value. Thus, the tab lists 1,10,20,30 and 1,10,+10,+10 are considered identical. If the name of a file is given, reads the first line of the file, searching for a format specification. If it finds one there, it sets the tab stops according to it, otherwise it sets them as This type of specification can be used to ensure that a tabbed file is printed with correct tab settings, and is suitable for use with the command (see pr(1)): Any of the following can be used also; if a given option occurs more than once, the last value given takes effect: usually needs to know the type of terminal in order to set tabs and always needs to know the type to set margins. type is a name listed in term(5). If no option is supplied, searches for the value in the environment (see environ(5)). If is not defined in the environment, tries a sequence that will work for many terminals. The margin argument can be used for some terminals. It causes all tabs to be moved over n columns by making column n+1 the left margin. If is given without a value of n, the value assumed is 10. The normal (left-most) margin on most terminals is obtained by The margin for most terminals is reset only when the option is given explicitly. Tab and margin setting is performed via the standard output. EXTERNAL INFLUENCES
Environment Variables determines the interpretation of text within file as single- and/or multi-byte characters. determines the language in which messages are displayed. If or is not specified in the environment or is set to the empty string, the value of is used as a default for each unspecified or empty variable. If is not specified or is set to the empty string, a default of "C" (see lang(5)) is used instead of If any internationalization variable contains an invalid setting, behaves as if all internationalization variables are set to "C". See environ(5). International Code Set Support Single- and multi-byte character code sets are supported. DIAGNOSTICS
Arbitrary tabs are ordered incorrectly. A zero or missing increment found in an arbitrary specification. A ``canned'' code cannot be found. option was used and file cannot be opened. option was used and the specification in that file points to yet another file. Indirection of this form is not permitted. WARNINGS
There is no consistency among different terminals regarding ways of clearing tabs and setting the left margin. It is generally impossible to usefully change the left margin without also setting tabs. clears only 20 tabs (on terminals requiring a long sequence), but is willing to set 64. SEE ALSO
nroff(1), pr(1), tset(1), environ(5), term(5). STANDARDS CONFORMANCE
tabs(1)
All times are GMT -4. The time now is 05:58 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy