12-04-2005
Hi
Probably not the best idea to ask for upgrade process from the web, however you should be fine in doing what you suggest.
Take at least 2 backups of the data, as well as your standard backup and have all 3 sets of disks on site for the upgrade. I have seen many times, specifically with DB backups where the first backup used doesn't work.
I would also make sure the disks are unmounted from the system before you physically pull them out or that the system is powered off (I'm unsure if your system provides hotswap).
When you replace the disks make sure they are accessible and fine and you can see and use them on the system.
Once confirmed you should be good to recover the data from the tapes.
Thanks
6 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hello folks,
I have a sun sparcstation 20, I would like to upgrade one of the hard disks to a larger one. The one I would like to upgrade only contains user data. Here are my thoughts:
1. Backup the specific file system
2. Replace the disk with the larger disk
3. Create a new file... (2 Replies)
Discussion started by: DLongan
2 Replies
2. AIX
I've tried to upgrade the 9gb drives in our F50's to 18gb. The system with original drives would boot up in about 4 min., but with the 18gb drives takes 17 min. Running 4.2.1. What am I missing here?? (5 Replies)
Discussion started by: mooshkie
5 Replies
3. Solaris
I need to upgrade 2 x 73 GB disk and replace with 2 x 146 GB disk in sun v240.
These disks contain boot and swap files
These are mirrored disks with RAID 1
I am trining to create the correct procedure.
So far the procedure I have is as follows:
# metastat
State: Okay
... (5 Replies)
Discussion started by: photon
5 Replies
4. UNIX for Dummies Questions & Answers
Plan to upgrade Solaris from version 8 to version 9. Understand that if the boot disk is mirrored, I need to split it first before upgrade, how can I do that?
Please advise.
Thank you. (2 Replies)
Discussion started by: KhawHL
2 Replies
5. HP-UX
Hi there
I have a 3600 C class PA-RISC workstation, and I am wondering if I can increase the disk capacity on it.
I have a couple of 73GB Seagate SCSI disks which I could fit in to the SCA slots, and if they are not suitable I am willing to find alternatives - but I am not sure how to go... (3 Replies)
Discussion started by: Freddo_21
3 Replies
6. Solaris
Hi,
I have Solaris-10 x86 (running on HP hardware), with 12 non-global zones running on this. I have to install latest patch cluster/set on this server. This server is not under backup schedule, so before installing patch cluster, I want to keep a backup. In case of any issue (bad patch or... (4 Replies)
Discussion started by: solaris_1977
4 Replies
LEARN ABOUT DEBIAN
mkqdisk
mkqdisk(8) Quorum Disk Management mkqdisk(8)
NAME
mkqdisk - Cluster Quorum Disk Utility
WARNING
Use of this command can cause the cluster to malfunction.
SYNOPSIS
mkqdisk [-?|-h] | [-L] | [-f label] [-c device -l label] [-d [-d ...]]
DESCRIPTION
The mkqdisk command is used to create a new quorum disk or display existing quorum disks accessible from a given cluster node.
OPTIONS
-c device -l label
Initialize a new cluster quorum disk. This will destroy all data on the given device. If a cluster is currently using that device
as a quorum disk, the entire cluster will malfunction. Do not run this on an active cluster when qdiskd is running. Only one
device on the SAN should ever have the given label; using multiple different devices is currently not supported (it is expected a
RAID array is used for quorum disk redundancy). The label can be any textual string up to 127 characters - and is therefore enough
space to hold a UUID created with uuidgen(1).
-f label
Find the cluster quorum disk with the given label and display information about it.
-L Display information on all accessible cluster quorum disks.
-d Increase debugging level. Specify multiple times for more information. Currently, specifying more than twice has no effect.
SEE ALSO
qdisk(5), qdiskd(8), uuidgen(1)
July 2006 mkqdisk(8)