Sponsored Content
Top Forums UNIX for Advanced & Expert Users Solaris 8 disk/mirroring issue Post 88742 by ghuber on Tuesday 8th of November 2005 11:26:37 AM
Old 11-08-2005
Solaris 8 disk/mirroring issue

Hello!

I recently inherited system administration duties for a SUN v880 box. The system has 6 physical hard disks.. In doing some basic maintenance, I found they're configured for mirroring. I ran the metastat and metadb commands, and many of the mirrors are showing they are in need of maintenance -> See the attachments.

Question is -- How do get all the mirrors back online and functional? I was considering running the metareplace utility to enable the metabases, but it seems as if one of the hard disks is no longer being recongized by the system. (c1t3d0 -> see disks.txt) I've checked the /var/adm/message files but I don't see anything that would indicate the disk has failed, and the front status panel of the server itself (Including the error condition lights for each drive) is showing no problems... I was thinking of running touch /reconfigure, seeing the disk is redetected, if it is, then replacing the failed metabases using the metareplace and rebooting. Do you guys feel this will fix the problem?

Any advice would be greatly appreciated!
 

10 More Discussions You Might Find Interesting

1. Solaris

Solaris mirroring / non-root disk

Hi Guys, Need to add 2 disks into a JBOD array (3310). Does anyone see anything wrong with my Procedure / Doco below? 1> Logon to system, check system logs for abnormal entries. 2> Make backups of related system files: A>cp -p /etc/system /etc/system.backup.081505 B>cp -p /etc/vfstab... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. Solaris

[HELP] mirroring disk at solaris 8 sparc v890

hi expert, sorry i'm new in solaris system, need more advice and help :) i'm confusing with mirroring disk at my sparc v890 solaris 8, i have 6 harddisk which the structure shown below : format : AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> ... (4 Replies)
Discussion started by: bucci
4 Replies

3. Solaris

Help !! disk Mirroring

Hi I have a Sunfire X4100 box with a 4 disk Chassis (although I only have 2 disks in it). I have been asked to add two more disks into the chassis so that I can mirror the original two using SVM .....Ive read through a couple of SVM docs but am finding it a little confusing, and if any of you... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

4. Solaris

Disk Mirroring for Solaris 10 x86

I am having an issue with setting up disk mirroring for Solaris 10 on an x86 server. My main problem is that the volumes and slices have already been setup and our proprietary software has already been installed and configured. The entire drive has been allocated in this configuration and the... (2 Replies)
Discussion started by: chuck43
2 Replies

5. Solaris

Solaris 10 Disk Mirroring

Has anyone managed to set up disk mirroring in Solaris 10 yet? If so can you point me in the direction of some useful documentation please. Cheers (25 Replies)
Discussion started by: korfnz
25 Replies

6. Solaris

Disk Mirroring on solaris 5.8

Hi Friends, I am having Sun Solaris 5.8 OS installed having 2 different size hard disk, sizes are c0t0d0s0(160 GB) and c0t2d0s0 (40GB). I have installed Sun Solaris 5.8 OS in c0t0d0s0 (160GB) harddisk. I have configured all the parameters required for disk mirroring. But when executing... (4 Replies)
Discussion started by: Vijayakumarpc
4 Replies

7. Solaris

root disk mirroring in solaris volume manager for solaris 10

Need a procedure document to do "root disk mirroring in solaris volume manager for solaris 10". I hope some one will help me asap. I need to do it production environment. Let me know if you need any deatils on this. Thanks, Rama (1 Reply)
Discussion started by: ramareddi16
1 Replies

8. Solaris

Solaris Mirroring/Hotspare Issue

Hi Guys, I have an issue with my Hotspares/Metastat on an x4270m2. I have no hotspares available, when i printed out my metastat i got d21: Concat/Stripe Size: 33559785 blocks (16 GB) Stripe 0: Device Start Block Dbase Reloc ... (0 Replies)
Discussion started by: A-Train
0 Replies

9. Solaris

Root disk mirroring in Solaris 10

I would like to perform root disk mirroring task. Can someone please help me out on this. Thanks !! Regards, Rama (2 Replies)
Discussion started by: ramagore85
2 Replies

10. Solaris

Solaris 11 disk issue

I have 2 disks in my system.I recently added a zpool to the disk, but today I changed my mind and deleted the zpool , zpool destroy -f extra The zpool is now deleted and I want to partition the disk, so I delete the only partition on the disk. Now when I run format again, format... (13 Replies)
Discussion started by: cbtshare
13 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), mount(8), newfs(8), vinum(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 06:36 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy