I recently inherited system administration duties for a SUN v880 box. The system has 6 physical hard disks.. In doing some basic maintenance, I found they're configured for mirroring. I ran the metastat and metadb commands, and many of the mirrors are showing they are in need of maintenance -> See the attachments.
Question is -- How do get all the mirrors back online and functional? I was considering running the metareplace utility to enable the metabases, but it seems as if one of the hard disks is no longer being recongized by the system. (c1t3d0 -> see disks.txt) I've checked the /var/adm/message files but I don't see anything that would indicate the disk has failed, and the front status panel of the server itself (Including the error condition lights for each drive) is showing no problems... I was thinking of running touch /reconfigure, seeing the disk is redetected, if it is, then replacing the failed metabases using the metareplace and rebooting. Do you guys feel this will fix the problem?
Hi Guys,
Need to add 2 disks into a JBOD array (3310).
Does anyone see anything wrong with my Procedure / Doco below?
1> Logon to system, check system logs for abnormal entries.
2> Make backups of related system files:
A>cp -p /etc/system /etc/system.backup.081505
B>cp -p /etc/vfstab... (3 Replies)
hi expert,
sorry i'm new in solaris system, need more advice and help :)
i'm confusing with mirroring disk at my sparc v890 solaris 8, i have 6 harddisk which the structure shown below :
format :
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
... (4 Replies)
Hi
I have a Sunfire X4100 box with a 4 disk Chassis (although I only have 2 disks in it). I have been asked to add two more disks into the chassis so that I can mirror the original two using SVM .....Ive read through a couple of SVM docs but am finding it a little confusing, and if any of you... (1 Reply)
I am having an issue with setting up disk mirroring for Solaris 10 on an x86 server. My main problem is that the volumes and slices have already been setup and our proprietary software has already been installed and configured. The entire drive has been allocated in this configuration and the... (2 Replies)
Has anyone managed to set up disk mirroring in Solaris 10 yet? If so can you point me in the direction of some useful documentation please.
Cheers (25 Replies)
Hi Friends,
I am having Sun Solaris 5.8 OS installed having 2 different size hard disk, sizes are c0t0d0s0(160 GB) and c0t2d0s0 (40GB). I have installed Sun Solaris 5.8 OS in c0t0d0s0 (160GB) harddisk.
I have configured all the parameters required for disk mirroring. But when executing... (4 Replies)
Need a procedure document to do "root disk mirroring in solaris volume manager for solaris 10". I hope some one will help me asap. I need to do it production environment.
Let me know if you need any deatils on this.
Thanks,
Rama (1 Reply)
Hi Guys,
I have an issue with my Hotspares/Metastat on an x4270m2.
I have no hotspares available, when i printed out my metastat i got
d21: Concat/Stripe
Size: 33559785 blocks (16 GB)
Stripe 0:
Device Start Block Dbase Reloc
... (0 Replies)
I have 2 disks in my system.I recently added a zpool to the disk, but today I changed my mind and deleted the zpool ,
zpool destroy -f extra
The zpool is now deleted and I want to partition the disk, so I delete the only partition on the disk.
Now when I run format again,
format... (13 Replies)
Discussion started by: cbtshare
13 Replies
LEARN ABOUT OSF1
volreattach
volreattach(8) System Manager's Manual volreattach(8)NAME
volreattach - Reattaches disk drives that have once again become accessible
SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...]
/usr/sbin/volreattach -c accessname
OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the
failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the
name of the disk group and disk media name at which the disk can be reattached is displayed.
DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment.
This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical
Storage Manager is started, causing disks to enter the failed state.
If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the
reattach happens before any volumes on the disk are started.
The volreattach command is called from the voldiskadm menus as part of disk recovery.
The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching
disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists.
EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned.