Sponsored Content
Full Discussion: Booting problem Veritas
Operating Systems Solaris Booting problem Veritas Post 85170 by Perderabo on Monday 3rd of October 2005 07:20:43 AM
Old 10-03-2005
Here is something else to check: If the box is in diagnostic mode, boot-device is ignored and the box will boot from the value stored in diag-device instead. The variable diagnostic-mode? controls whether or not you are in diagnostic mode.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Problem with booting

Hi! I installed Slackware on my computer so I thought I could have dual booting with ME, but that didn't work. So I installed another bootmanager that I find on internet. When I startup my computer the second bootmangaer that I did find on internet lets me choose system. When I have choosen... (3 Replies)
Discussion started by: Mr.Rudiment
3 Replies

2. UNIX for Advanced & Expert Users

Booting Problem

Hai I have installed win 98 o.s in my system after that i have installed Red Hat Linux 7.0,there is a problem in dual booting,by default win98 is being booted, when i insert bootable linux floppy linux is loaded My doubt how to overwrite windows MBR and palce the lilo in MBR.so that it... (2 Replies)
Discussion started by: rajashekaran
2 Replies

3. UNIX for Dummies Questions & Answers

<< booting problem with redhat 8.0 >>

i have the Redhat installed in this Hard Drive and i wanna use it in this old computer of mine.. it works fine in my new computer.. but when i put it in my old one.. which is.. P1 150MHz 32MBramz it wont load the kernal and keeps on restarting the computer.. keeps on goin like this.. i get the GRUB... (2 Replies)
Discussion started by: dezithug
2 Replies

4. Solaris

booting problem

any one can help me. my system running on solaris 2.7. recently there is sudden power failure while system running. after that unable to boot the system. it is giving comment that "can not open /etc/path_to_inst" and then returning back to "OK" after comment of termination. The processor is... (10 Replies)
Discussion started by: prabir
10 Replies

5. UNIX for Dummies Questions & Answers

problem booting

Dear List, While I was adding second hard disk to my system, I changed the /etc/fstab file by adding the following line: /mnt/sdb1 /dev/sdb1 ext3 default 2 1 Now system does not boot and gives the following error: Checking filesystems /: Clean, 309260/18495840 files, 1064776/18486790... (2 Replies)
Discussion started by: siavoush
2 Replies

6. Solaris

Veritas Multipathing problem.

Hi, Basically the original configuration on my Solaris 9 server was two LUNs configured as Veritas file systems that were connected to a NetApp filer (filer1). These two LUNs are still configured on the server - but are not being used. They are there as a backup just in case the new... (0 Replies)
Discussion started by: sparcman
0 Replies

7. Solaris

problem in volume resizing in veritas

Hi all i have a veritas volume with the size of 600MB and formatted with vxfs filesystem. I want to grow the filesystem to 700MB. I knew that three ways are there to resize. vxresize, vxvol and vxassit. vxresize works fine. I want to try the same thing with vxvol and vxassist. Can someone tell me... (4 Replies)
Discussion started by: kingston
4 Replies

8. AIX

AIX Booting problem

Hi, I have IBM RS/6000 44P MODEL 170 server with Aix 5.1 Till the morning server is working fine, i turned off properly but now i tried to start it is showing below error on LED and going down (power off) E051 >>>E0E0 >>>> E0E1>>>> 种种种种 >>>> 40210014 P1-C1-F1 ccccccc >>>> 40210014 >>>>E043... (3 Replies)
Discussion started by: ANAND KURADE
3 Replies

9. AIX

Booting problem

Dears, I have a problem when i reboot the machine last time "AIX 5.3", that after rebooting it not login to graphical desktop, it just stop at console login command line. Kindly find the attached screenshot. Anyway to let it login automatically to Desktop? Would appreciate any pointers to... (1 Reply)
Discussion started by: moudmm
1 Replies

10. AIX

Problem to booting up p730

Hi Everyone, We have IBM p730 that I am trying to booting up to AIX 7.1. But it stops at RUNTIME. C7004087 C7004091 C7004091 (show is code number twice) STANDBY RUNTIME The explanation for C7004091 is the final IPL status progress code to be displayed before the system reaches... (5 Replies)
Discussion started by: lilyn
5 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 09:39 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.