Sponsored Content
Full Discussion: Need help from E280R owners
Operating Systems Solaris Need help from E280R owners Post 75365 by Don.Key on Friday 17th of June 2005 07:40:05 AM
Old 06-17-2005
Question Need help from E280R owners

Hello,

I have recently aquired an E280R chassis, that is one of the first E280R chassis so it still features old fan block from 420R (540-4434).

Unfortunately I have 900Mhz X7009A CPUs to go into this machine and those need a better fan block (540-5088) because they do overheat Smilie.

Could someone who currently owns a E280R with 540-5088 fan cage tell me which fans are used there? It is easely visible if you open the top cover.

Many, many thanks ahead.

Don
 

4 More Discussions You Might Find Interesting

1. AIX

Identifying Semaphore Owners

Hi, I have an AIX server which has a number of root owned semaphores. Is there a way of identifying which processes/threads own these processes so that they can be removed. I there also a way to remove shared memory segments in a similar way Thanks. \ (1 Reply)
Discussion started by: backslash
1 Replies

2. Shell Programming and Scripting

Find only files/directories with different permissions/owners

My git post-update has the following lines in it to make sure the permissions are set right: find /usr/local/apache/htdocs -type d -print0 | xargs -0 chmod 755 find /usr/local/apache/htdocs -type f -print0 | xargs -0 chmod 644 chown -R apache:apache /usr/local/apache/htdocsThe only problem is... (5 Replies)
Discussion started by: dheian
5 Replies

3. UNIX for Dummies Questions & Answers

Awk/script to list the owners of files

I have to list the files in a directory and along with that, list the owner of each of those files. Can someone please help me with a way to get this info please? Gayathri (2 Replies)
Discussion started by: ggayathri
2 Replies

4. HP-UX

Script execution is very slow when trying to find all files and their owners on HP-UX box

Hi, I have a HP-UX server were I need to list all the files in the entire file system, their directory path, last modified date, owner and group. I do not need to search the file contents. I created the script given below and I am excluding directories and files of type tmp, temp and log. The... (4 Replies)
Discussion started by: Adyan Faruqi
4 Replies
envd(1M)																  envd(1M)

NAME
envd - system physical environment daemon SYNOPSIS
configfile] DESCRIPTION
The daemon provides a means for the system to respond to environmental conditions detected by hardware. Such responses are typically designed to maintain file system integrity and prevent data loss. The environmental conditions currently recognized by are over-tempera- ture and chassis fan failure. logs messages and then executes actions when a supported environmental event is detected. Whether to do message logging and what actions to perform for a given environmental event are determined by configfile (default is If no option was specified and the default configfile does not exist, fails. A recommended default configfile is available in The configfile (or is only examined when the daemon is started or when it receives a signal to restart and re-initialize the daemon itself. uses the message logging facility to log warning messages. If configfile specifies messages to be logged, the destination of the warning messages is determined by the configuration of the facility of the daemon (see syslogd(1M) and syslog(3C) for details) and various priori- ties defined below for the corresponding environmental events. Warning messages are written to the console if is unable to send to The configfile is composed of event lines, each of which followed by zero or more action lines. Comment lines can be interspersed at any point. No more than one event line can be specified for a given event. Event Event lines consist of an event keyword and a message indicator, separated by a colon Valid event keywords are and Valid message indicators are and An example is indicating that warning messages are to be sent for the event. Event keywords must start in the first column, and only one event and one message indicator are allowed on a given line. Action Action lines can consist of a sequence of any valid commands or pipelines. Lines from one event line to the next event line, or to the end of the file, are part of the action lines for the preceding event, and are passed intact to the shell to execute upon detecting the event. The action for an event can span across several lines, but the syntax of every line must be understood by There are no default actions for any events if no action lines are specified. No parsing or syntax checking is performed on the action lines; system administrators are responsible for verifying the correctness of the action syntax. Comments Lines beginning with the character in the first column are comment lines, and all characters up to the subsequent new-line character are ignored. Blank lines are ignored as comment lines. Here is an example file: Only users with appropriate privileges can invoke Over-temperature and Fan Failure Handling Over-temperature and fan failure handling is supported only on systems equipped with appropriate sensing hardware. Over-temperature and fan failure limits vary, depending on the hardware. Each system processor defines its own thresholds for supported equipment combinations. The table below shows temperature and fan failure states. For the temperature ranges and fan states specific to your system configuration, refer to any of the following documents for your system: or +-------------------+-------------------------------------------+ |State | State Description | +-------------------+-------------------------------------------+ |NORMAL | Within normal operating temperature range | |OVERTEMP_CRIT | Temperature has exceeded the normal oper- | | | ating range of the system, but is still | | | within the operating limit of the hard- | | | ware media. | |OVERTEMP_EMERG | Temperature has exceeded the maximum | | | specified operating limit of hardware | | | media; power loss is imminent. A minimum | | | of about 60 seconds is guaranteed between | | | the OVERTEMP_MID state and the | | | OVERTEMP_POWERLOSS (power loss) state. | |OVERTEMP_POWERLOSS | Hardware will disconnect all power from | | | all cards in the system chassis. | |FAN_NORMAL | All chassis fans are operating normally. | |FANFAIL_CRIT | One or more chassis fans have failed, but | | | the system has enough redundant fans to | | | allow continued operation while the | | | failed fans are replaced. | |FANFAIL_EMERG | Chassis fan failures prevent continued | | | operation of the system; power loss is | | | imminent. | |FANFAIL_POWERLOSS | Hardware will disconnect all power from | | | all cards in the system chassis. | +-------------------+-------------------------------------------+ The priorities mapped to the environmental events are: (for and and (for and Any non-shutdown activities (e.g. file transfer) should be performed at and It is important to configure only critical activities for because the over-temperature might rise dramatically fast to It is recommended to perform a quick shutdown using at and to preserve file system data integrity. If the hardware enters the or state and the system has not been shut down, the sudden loss of power could result in data loss. Note that power-fail recovery functionality is not available in this case. When the hardware powers down, no warning messages are produced, and no action is taken by the system. Whenever an environmental state changes from one level to another (such as from to or from to the warning message, if specified, is logged, and the corresponding action is executed once, and only once, per state change. AUTHOR
was developed by HP. FILES
executable file default configuration file default configuration file work files SEE ALSO
reboot(1M), shutdown(1M), syslogd(1M), syslog(3C), envd(1M)
All times are GMT -4. The time now is 03:30 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy